← Back
Primarily 2 family with 1 store or office
180-05 JAMAICA AVENUE
QUEENS · Jamaica · BIN 4211688
💬 Discuss this project
1920Year Built
2Stories
S2Building Class
R6AZoning
2,250 sfGross Floor Area
3Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · 1,854 sf lot · 1.21 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Floor 1Under Construction24p · 3 filings · 20 docs
CellarUnder Construction29p · 2 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1 EIGHTY MANAGEMENT TEAM1004/09/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC111/05/2025
KYLE MAY, ARCHITECT304/16/2025
PROSPECT ENGINEERING P.C103/28/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AK CONSULTING SERVICES603/21/2026
BMB BUILDING CONSULTING203/21/2026
Doner King NYC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PUREWAL CONTRACTORS INCGeneral Contractor304/09/2026
M BURTON P & H CORPPlumbing107/08/2026
UNITECH DESIGNScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746111/05/2025
AK CONSULTING SERVICES, I6198304/16/2025
Building Lifecycle
All (44)Filed (5)Permit Issued (4)Signed Off (1)Violation (13)Inspection (5)Objection (8)Special Inspection (8)
07/08/2026
Objection resolved — Resolved
11/25/2025
Violation issued (HPD, open)
I
11/18/2025
Permit issued — Plumbing
Q01309137-I1-PL
11/10/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/05/2025
Filed — Alteration
REPLACE GAS-FIRED COMMERCIAL COOKING APPLIANCES AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01309137-I1
10/27/2025
Special inspection requirement — Tenant Protection Plan Compliance
Stephen Shishko
07/23/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/23/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/30/2025
Objection raised — Scope
04/16/2025
Filed — Alteration
REPAIR OF DEMISING INTERIOR WALL IN CELLAR, 1ST FLOOR. NO CHANGES TO EGRESS, USE, OCCUPANCY, OR NUMBER OF UNITS.
Q00997808-P2
04/07/2025
Permit issued — General Construction
Q00997808-I1-GC
01/27/2025
Special inspection requirement — Final
KYLE MAY
01/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAHFUZAR RAHMAN
12/05/2024
Violation issued (HPD, open)
I
08/09/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAHFUZAR RAHMAN
07/29/2024
Special inspection requirement — Final
KYLE MAY
07/18/2024
Objection resolved — Addressed
07/18/2024
Objection resolved — Addressed
07/18/2024
Objection resolved — Addressed
06/20/2024
Objection raised — Scope
06/20/2024
Objection raised — Scope
06/20/2024
Objection raised — Scope
06/13/2024
Filed — Alteration
REPAIR OF DEMISING INTERIOR WALL IN CELLAR, 1ST FLOOR. NO CHANGES TO EGRESS, USE, OCCUPANCY, OR NUMBER OF UNITS.
Q00997808-P1
05/29/2024
Special inspection requirement — Final
KYLE MAY
05/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAHFUZAR RAHMAN
03/20/2024
Permit issued — General Construction
Q00997808-I1-GC
02/20/2024
Filed — Alteration
REPAIR OF DEMISING INTERIOR WALL IN CELLAR, 1ST FLOOR. NO CHANGES TO EGRESS, USE, OCCUPANCY, OR NUMBER OF UNITS.
Q00997808-I1
11/29/2023
Violation issued (HPD, open)
I
01/26/2023
Violation issued (FDNY_ORDER, closed)
01/26/2023
Violation issued (FDNY_ORDER, closed)
01/26/2023
Violation issued (FDNY_NOV, closed)
12/14/2022
Violation issued (FDNY_ORDER, closed)
11/18/2022
Violation issued (HPD, open)
I
05/23/2022
Signed off — Alteration
Q00687277-I1
05/19/2022
Inspection — Pass-Final Sign Permit Inspection
Pass
View inspection ↗
04/14/2022
Permit issued — Sign
Q00687277-I1-SG
03/28/2022
Filed — Alteration
Q00687277-I1
03/17/2022
Violation issued (HPD, closed)
I
02/25/2022
Special inspection requirement — Final
JUSTIN KIM
11/29/2021
Violation issued (ECB, closed)
Construction
04/22/2021
Violation issued (HPD, closed)
I
11/07/2019
Violation issued (HPD, closed)
I
04/12/1998
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedM BURTON P & H CORP11/18/2025
DOB NOWGeneral ConstructionPermit IssuedPUREWAL CONTRACTORS INC04/07/2025
DOB NOWGeneral ConstructionPermit IssuedPUREWAL CONTRACTORS INC03/20/2024
DOB NOWSignSigned-offUNITECH DESIGN INC04/14/2022
BISFPISSUEDFIRE COMMAND CO, INC06/24/2015
BISFPISSUEDIDEAL FIRE CONTROL, INC.09/19/2000
BISPLISSUEDSAMCO MECHANICAL CORP.02/02/1999
BISFPISSUEDMETFLOW FIRE CONTROL LLC06/07/1993
BISPLRE-ISSUEDSAMCO MECHANICAL CORP04/19/1993
BIS—RE-ISSUEDSAMCO MECHANICAL CORP03/04/1993
1 project · most recent 11/05/2025
Gas
FiledStatusContractorScope
11/05/2025Permit IssuedM BURTON P & H CORPGas
3 projects · most recent 05/06/2022
General Wiring
FiledStatusContractorScope
05/06/2022CompleteATMOS ELECTRIC SVCE CORP—
04/12/2022CompleteATMOS ELECTRIC SVCE CORP—
02/06/2022CompleteATMOS ELECTRIC SVCE CORPGeneral Wiring
1 project · most recent 11/05/2025
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
11/05/2025Permit IssuedM BURTON P & H CORPTenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
11/10/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/23/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/23/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/09/2024Fail-Final General Construction Non-Directive 14FailView ↗
05/19/2022Pass-Final Sign Permit InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
10/27/2025Tenant Protection Plan ComplianceStephen Shishkospecial
01/27/2025FinalKYLE MAYprogress
01/27/2025Fire-Resistant Penetrations and JointsMAHFUZAR RAHMANspecial
07/29/2024Fire-Resistant Penetrations and JointsMAHFUZAR RAHMANspecial
07/29/2024FinalKYLE MAYprogress
05/29/2024FinalKYLE MAYprogress
05/29/2024Fire-Resistant Penetrations and JointsMAHFUZAR RAHMANspecial
02/25/2022FinalJUSTIN KIMprogress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/26/2026Q00687277-I1Request digital key ↗
08/22/2026Q00997808-P2Request digital key ↗
08/22/2026Q00997808-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
07/07/2015421067348Open ↗
▸BISWORK PERMIT APPLICATION1
06/30/2015421067348Open ↗
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/18/2026Q01309137-I1Open ↗
08/13/2026Q00997808-I1Open ↗
08/13/2026Q00687277-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q00997808-P2Open ↗
08/28/2026Q00687277-I1Open ↗
08/25/2026Q00997808-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026Q00997808-P2Open ↗
08/28/2026Q01309137-I1Open ↗
08/25/2026Q00997808-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026Q00997808-I1Open ↗
08/13/2026Q00997808-P2Open ↗
08/13/2026Q00687277-I1Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
06/05/2015421067348Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
07/07/2015421067348Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
06/05/2015421067348Open ↗