← Back
Hospital, sanitarium, mental institution
The Beacon
180 FT WASHINGTON AVENUE · BIN 1091883
💬 Discuss this project
1930Year Built
22Stories
I1Building Class
R8Zoning
3,693,539 sfGross Floor Area
1Units
LL97 Covered14 Open Violations 0 unresolved · 14 paperwork only ▸FDNY Report ↗
Hospital, sanitarium, mental institution · 364,433 sf lot · 10.14 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionEquipment
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 6 docs
Floor 17Under Construction1 filing · 18 docs
Floor 16Under Construction1 filing · 18 docs
Floor 15Under Construction1 filing · 18 docs
Floor 14Under Construction1 filing · 18 docs
Floor 13Under Construction97p · 2 filings · 20 docs
Floor 12Under Construction95p · 2 filings · 20 docs
Floor 11Under Construction96p · 2 filings · 20 docs
Floor 10Under Construction96p · 2 filings · 20 docs
Floor 9Under Construction1 filing · 18 docs
Floor 8Under Construction1 filing · 18 docs
Floor 7Under Construction1 filing · 18 docs
Floor 6Under Construction1 filing · 18 docs
Floor 5Under Construction1 filing · 18 docs
Floor 4Under Construction1 filing · 18 docs
Floor 3Under Construction1 filing · 18 docs
Floor 2Under Construction12p · 2 filings · 20 docs
Floor 1Under Construction13p · 5 filings · 20 docs
CellarUnder Construction103p · 2 filings · 20 docs
BasementUnder Construction12p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK PRESBYTERIAN HOSPITAL3609/13/2026
GRAMERCY GROUP203/22/2026
CONSIGLI CONSTRUCTION103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL EXPEDITING2803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLATFORM SOLUTIONS, INCGeneral Contractor907/08/2026
CONSIGLI CONSTRUCTION COGeneral Contractor608/16/2026
TURNER CONSTRUCTION COMPANYGeneral Contractor509/07/2026
RAEL AUTOMATIC SPR.CO INCFire Protection306/28/2026
ALLIANCE PLUMBING CORPPlumbing207/08/2026
NEW YORK BOOM TRUCKSGeneral Contractor108/21/2026
CIVETTA COUSINS JV, L.L.CGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALAN MARGOLIN & ASSOC4231404/27/2026
LANGAN ENG, ENV, SURVEYIN1265501/14/2026
Building Lifecycle
All (133)Filed (31)Permit Issued (27)Violation (4)Inspection (15)Objection (26)Special Inspection (30)
09/03/2026
Permit issued — Structural
M01036737-Z4-ST
08/20/2026
Permit issued — Protection and Mechanical Methods
M01439333-I1-PMM
08/17/2026
Filed — Alteration
Installation and use of knuckleboom temporary construction equipment as per plans filed herewith. This application is filed in conjunction with NB M01036737-I1.
M01439333-I1
08/14/2026
Permit issued — Earth Work
M01036737-S6-EA
08/13/2026
Permit issued — Support of Excavation
M01036737-S5-SE
08/12/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
07/27/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/07/2026
Filed — Alteration
EQUIPMENT USE: INSTALLATION OF A TEMPORARY PERSONNEL HOIST (CAR # 4) AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH CHAPTER 33 OF 2022 NYC BUILDING CODE.
M01400198-P2
07/01/2026
Filed — Alteration
EQUIPMENT USE: INSTALLATION OF A TEMPORARY PERSONNEL HOIST (CAR # 4) AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH CHAPTER 33 OF 2022 NYC BUILDING CODE.
M01400198-P1
06/30/2026
Filed — Alteration
INSTALLATION OF TEMPORARY SCAFFOLD STAIR TOWERS AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M01398797-P1
06/26/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/25/2026
Filed — Alteration
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. ROOF PROTECTION SHALL COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M01398772-P1
06/22/2026
Permit issued — Foundation
M01036737-S1-FO
06/12/2026
Filed — Alteration
EQUIPMENT USE: INSTALLATION OF A TEMPORARY PERSONNEL HOIST (CAR # 4) AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH CHAPTER 33 OF 2022 NYC BUILDING CODE.
M01400198-S3
06/12/2026
Permit issued — Protection and Mechanical Methods
M01400198-S3-PMM
06/12/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/12/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/12/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/28/2026
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. FENCE SHALL COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M01379457-P1
05/22/2026
Permit issued — Standpipe
M01390678-I1-EW-SD
05/21/2026
Permit issued — Plumbing
M01036737-Z1-PL
05/21/2026
Permit issued — Plumbing
M01036737-Z6-PL
05/20/2026
Permit issued — Protection and Mechanical Methods
M01400198-S2-PMM
05/20/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
05/19/2026
Filed — Alteration
EQUIPMENT USE: INSTALLATION OF A TEMPORARY PERSONNEL HOIST (CAR # 4) AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH CHAPTER 33 OF 2022 NYC BUILDING CODE.
M01400198-S2
05/19/2026
Filed — Alteration
EQUIPMENT USE: INSTALLATION OF A TEMPORARY PERSONNEL HOIST (CAR # 4) AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH CHAPTER 33 OF 2022 NYC BUILDING CODE.
M01400198-S1
05/19/2026
Permit issued — Protection and Mechanical Methods
M01400198-S1-PMM
05/18/2026
Filed — Alteration
EQUIPMENT USE: INSTALLATION OF A TEMPORARY PERSONNEL HOIST (CAR # 4) AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION . NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH 2022 NYC BUILDING CODE, CHAPTER 33.
M01400388-I1
05/18/2026
Permit issued — Protection and Mechanical Methods
M01400388-I1-PMM
05/12/2026
Permit issued — Protection and Mechanical Methods
M01400198-I1-PMM
05/11/2026
Filed — Alteration
EQUIPMENT USE: INSTALLATION OF A TEMPORARY PERSONNEL HOIST (CAR # 4) AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH CHAPTER 33 OF 2022 NYC BUILDING CODE.
M01400198-I1
05/08/2026
Permit issued — Protection and Mechanical Methods
M01398772-I1-PMM
05/08/2026
Permit issued — Supported Scaffold
M01398797-I1-SF
05/08/2026
Permit issued — Protection and Mechanical Methods
M01398152-I1-PMM
05/07/2026
Filed — Alteration
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. ROOF PROTECTION SHALL COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M01398772-I1
05/07/2026
Filed — Alteration
INSTALLATION OF A TEMPORARY PERSONNEL HOIST AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. HOIST INSTALLED IN ACCORDANCE WITH 2022 NYC BUILDING CODE, CHAPTER 33.
M01398152-I1
05/07/2026
Filed — Alteration
INSTALLATION OF TEMPORARY SCAFFOLD STAIR TOWERS AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M01398797-I1
04/27/2026
Filed — Alteration
Filing for Temporary Standpipe during construction.
M01390678-I1
04/27/2026
Permit issued — Structural
M01036737-Z4-ST
04/23/2026
Permit issued — Structural
M01036737-Z4-ST
04/21/2026
Permit issued — General Construction
M01036737-I1-GC
04/21/2026
Permit issued — Foundation
M01036737-Z3-FO
04/21/2026
Special inspection requirement — Standpipe Systems
Young Suh
04/17/2026
Permit issued — Sprinklers
M01036737-Z7-EW-SP
04/17/2026
Permit issued — Sprinklers
M01036737-Z7-EW-SD
04/14/2026
Objection resolved — Addressed
04/06/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/31/2026
Objection resolved — Addressed
03/30/2026
Permit issued — Construction Fence
M01379457-I1-FN
03/27/2026
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. FENCE SHALL COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M01379457-I1
03/25/2026
Objection raised — Other
03/25/2026
Objection raised — Other
03/20/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/17/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/16/2026
Objection resolved — Addressed
03/13/2026
Permit issued — Supported Scaffold
M01362610-I1-SF
03/13/2026
Objection raised — Other
03/13/2026
Objection resolved — Addressed
03/13/2026
Objection resolved — Addressed
Latest 60 of 133 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedTURNER CONSTRUCTION COMPANY09/03/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedNEW YORK BOOM TRUCKS INC08/20/2026
DOB NOWEarth WorkPermit IssuedCONSIGLI CONSTRUCTION CO08/14/2026
DOB NOWSupport of ExcavationPermit IssuedCONSIGLI CONSTRUCTION CO08/13/2026
DOB NOWFoundationPermit IssuedCONSIGLI CONSTRUCTION CO06/22/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATFORM SOLUTIONS, INC06/12/2026
DOB NOWStandpipePermit IssuedRAEL AUTOMATIC SPR.CO INC05/22/2026
DOB NOWPlumbingPermit IssuedALLIANCE PLUMBING CORP05/21/2026
DOB NOWPlumbingPermit IssuedALLIANCE PLUMBING CORP05/21/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATFORM SOLUTIONS, INC05/20/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATFORM SOLUTIONS, INC05/19/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATFORM SOLUTIONS, INC05/18/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATFORM SOLUTIONS, INC05/12/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATFORM SOLUTIONS, INC05/08/2026
DOB NOWSupported ScaffoldPermit IssuedPLATFORM SOLUTIONS, INC05/08/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATFORM SOLUTIONS, INC05/08/2026
DOB NOWStructuralPermit IssuedTURNER CONSTRUCTION COMPANY04/27/2026
DOB NOWStructuralPermit IssuedTURNER CONSTRUCTION COMPANY04/23/2026
DOB NOWGeneral ConstructionPermit IssuedTURNER CONSTRUCTION COMPANY04/21/2026
DOB NOWFoundationPermit IssuedTURNER CONSTRUCTION COMPANY04/21/2026
DOB NOWSprinklersPermit IssuedRAEL AUTOMATIC SPR.CO INC04/17/2026
DOB NOWSprinklersPermit IssuedRAEL AUTOMATIC SPR.CO INC04/17/2026
DOB NOWConstruction FencePermit IssuedPLATFORM SOLUTIONS, INC03/30/2026
DOB NOWSupported ScaffoldPermit IssuedCIVETTA COUSINS JV, L.L.C03/13/2026
DOB NOWEarth WorkPermit IssuedCONSIGLI CONSTRUCTION CO07/22/2025
DOB NOWSupport of ExcavationPermit IssuedCONSIGLI CONSTRUCTION CO07/21/2025
DOB NOWFoundationPermit IssuedCONSIGLI CONSTRUCTION CO07/21/2025
1 project · most recent 01/14/2026
Air Conditioning Systems Generators Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/14/2026Permit IssuedTURNER CONSTRUCTION COMPAAir Conditioning Systems, Generators, Heating and Air Conditioning Systems, Heating Systems
Cooling
Liebert DME044C, PW011UC, CW051UC, PW029UC 42,000 BTU · Crac Unit ×35
Aaon RNA-026, RN-010, RNA-016 270,500 BTU · Rooftop Unit ×4
Trane 1 148,300 BTU · Ahu ×3
Colmac A+V123S-46-434-510.0C-2-EC-BPC-SD 5,387,000 BTU ×2
Heat / Cool
Trane 1 3,313,300 BTU · Ahu ×12
Iec CUSTOM 1,670 CFM · Fan Coil Indoor ×7
Multistack (10)MSH030KNA 4,290,000 BTU · Chiller ×3
Heating
Berko RH-47 33,800 BTU · Unit Heater ×10
HUHAA348 & CUH900 10,200 BTU · Unit Heater ×8
Iec CPY-8, HPY20 480 CFM · Fan Coil Indoor ×8
HDY30 3,500 CFM · Fan Coil Indoor ×2
Ventilation
__Junk__ EXHUST & SUPPLY DUCT AND FAN 1 BTU · Exhaust Fan ×1
Generators
__Junk__ 1 1 kW · Generator ×4
1 project · most recent 01/14/2026
Sprinkler System
FiledStatusContractorScope
01/14/2026Permit IssuedRAEL AUTOMATIC SPR.CO INCSprinkler System
1 project · most recent 01/14/2026
Medical Gas Storm Water/Sanitary
FiledStatusContractorScope
01/14/2026Permit IssuedCARDOZA PLUMBING CORPMedical Gas, Storm, Water/Sanitary
9 projects · most recent 09/01/2026
General Wiring
FiledStatusContractorScope
09/01/2026Permit IssuedJAM ELECTRICAL CORPGeneral Wiring
09/01/2026Permit IssuedJAM ELECTRICAL CORPGeneral Wiring
09/01/2026Permit IssuedJAM ELECTRICAL CORPGeneral Wiring
04/27/2026Permit IssuedALLRAN ELECTRIC OF NY LLC—
04/27/2026Permit IssuedALLRAN ELECTRIC OF NY LLC—
04/27/2026Permit IssuedALLRAN ELECTRIC OF NY LLC—
04/27/2026Permit IssuedALLRAN ELECTRIC OF NY LLC—
04/13/2026Permit IssuedALLRAN ELECTRIC OF NY LLC—
03/17/2026Permit IssuedALLRAN ELECTRIC OF NY LLC—
1 project · most recent 01/14/2026
FiledStatusContractorScope
01/14/2026Permit IssuedTURNER CONSTRUCTION COMPA5 scope_items
3 projects · most recent 06/30/2026
Scaffold Fence
FiledStatusContractorScope
06/30/2026Permit IssuedPLATFORM SOLUTIONS, INCScaffold
05/28/2026Permit IssuedPLATFORM SOLUTIONS, INCFence
03/10/2026Permit IssuedCIVETTA COUSINS JV, L.L.CScaffold
▾Field Inspections (DOB CAP) — 15
DateTypeResultReport
08/12/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
07/27/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/27/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/26/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/12/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/12/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/12/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/20/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/06/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/20/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/17/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/14/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/10/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/31/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/07/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
04/21/2026Standpipe SystemsYoung Suhspecial
02/04/2026Duct leakage testing, insulation and designYoung Suhenergy_progress
02/04/2026Fire-Resistant Penetrations and JointsYoung Suhspecial
01/29/2026FinalYoung Suhprogress
01/29/2026Subsurface Investigations (Borings/Test Pits)Alan Poeppelspecial
01/29/2026MasonryYoung Suhspecial
01/29/2026Construction Operations Influencing Adjacent StructuresYoung Suhspecial
01/29/2026Prestressed Rock and Soil AnchorsMarc Gallagherspecial
01/29/2026Post-installed AnchorsYoung Suhspecial
01/29/2026Subgrade InspectionsMarc Gallagherspecial
01/29/2026Footing and FoundationYoung Suhprogress
01/29/2026Subsurface Conditions – Fill Placement & In-Place DensityYoung Suhspecial
01/29/2026Concrete - Cast-In-PlaceYoung Suhspecial
01/12/2026Subgrade InspectionsMarc Gallagherspecial
01/11/2026Construction Operations Influencing Adjacent StructuresYoung Suhspecial
01/11/2026Subsurface Investigations (Borings/Test Pits)Arthur Alzamoraspecial
01/11/2026MasonryYoung Suhspecial
01/06/2026MasonryYoung Suhspecial
01/06/2026Construction Operations Influencing Adjacent StructuresYoung Suhspecial
01/06/2026Post-installed AnchorsYoung Suhspecial
01/06/2026Concrete - Cast-In-PlaceYoung Suhspecial
12/22/2025Smoke Control Systems TestingYoung Suhspecial
12/22/2025High-Pressure Steam Piping (Welding)Young Suhspecial
12/22/2025Heating SystemsYoung Suhspecial
12/22/2025Exhaust and Vent Systems in Plenums and DuctsYoung Suhspecial
Latest 25 of 56.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
NYP Cancer CenterMedical / Healthcare—
Project M01398797 Alteration · Permit Entire · 05/07/2026
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 182 on file (BIS + DOB NOW)
▸Plans & Drawings31
▸DOB NOWPlans/Sketch31
08/20/2026M01036737-S6Request digital key ↗
08/20/2026M01036737-S5Request digital key ↗
08/20/2026M01036737-Z8Request digital key ↗
Showing 3 of 31 on file for this type
▸Applications & Permits5
▸DOB NOWDEP Stormwater Construction Permit5
08/20/2026M01036737-S1Open ↗
08/13/2026M01036737-S6Open ↗
08/13/2026M01036737-P1Open ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records19
▸DOB NOWRestrictive Declaration/Easement 114
08/20/2026M01036737-S1Open ↗
08/13/2026M01036737-P1Open ↗
08/13/2026M01036737-Z1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram2
08/20/2026M01036737-I1Open ↗
08/13/2026M01036737-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/20/2026M01036737-I1Open ↗
08/13/2026M01036737-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026M01036737-I1Open ↗
▸Seals & Professional Certifications54
▸DOB NOWDPL-1: Design Professional Seal & Signature31
08/20/2026M01036737-S1Open ↗
08/18/2026M01439333-I1Open ↗
08/17/2026M01390678-I1Open ↗
Showing 3 of 31 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature17
09/23/2026M01036737-Z7Open ↗
09/01/2026M01036737-Z5Open ↗
09/01/2026M01390678-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026M01036737-Z5Open ↗
09/01/2026M01036737-Z5Open ↗
08/28/2026M01036737-S6Open ↗
Showing 3 of 6 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026M01036737-I1Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/20/2026M01036737-I1—
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026M01036737-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026M01036737-I1Open ↗
▸Environmental & Asbestos16
▸DOB NOWOER: Notice to Proceed16
08/20/2026M01036737-S5Open ↗
08/20/2026M01036737-S1Open ↗
08/20/2026M01036737-S1Open ↗
Showing 3 of 16 on file for this type
▸Inspections & Test Reports7
▸DOB NOWSOIL REPORT4
08/20/2026M01036737-S1Open ↗
08/13/2026M01036737-P1Open ↗
08/13/2026M01036737-S5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram3
08/13/2026M01036737-S5Open ↗
08/13/2026M01036737-Z3Open ↗
08/13/2026M01036737-S1Open ↗
▸Approvals, Objections & Sign-offs30
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter30
08/20/2026M01036737-S1Open ↗
08/18/2026M01439333-I1Open ↗
08/17/2026M01390678-I1Open ↗
Showing 3 of 30 on file for this type
▸Other Documents16
▸DOB NOWStructural Peer Review Report4
08/20/2026M01036737-S1Open ↗
08/13/2026M01036737-S5Open ↗
08/13/2026M01036737-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWGeotechnical Peer Review Report (BC 1818)3
08/20/2026M01036737-S1Open ↗
08/13/2026M01036737-P1Open ↗
08/13/2026M01036737-Z4Open ↗
▸DOB NOWWind Tunnel Test Report3
08/20/2026M01036737-S1Open ↗
08/13/2026M01036737-P1Open ↗
08/13/2026M01036737-Z4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/20/2026M01036737-I1Open ↗
08/13/2026M01036737-I1Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026M01036737-S6Open ↗
08/13/2026M01036737-S5Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026M01036737-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026M01036737-I1Open ↗