← Back
Miscellaneous two family
180 RUSSELL STREET
BROOKLYN · Greenpoint · BIN 3066519
💬 Discuss this project
1901Year Built
2Stories
B9Building Class
R6BZoning
1,770 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Miscellaneous two family · 2,000 sf lot · 0.89 FAR built · Flood zone X500
Locations of Work
ArchitectureElectricalPlumbingCivil
Roof2p · 1 filing · 20 docs
Floor 21p · 1 filing · 9 docs
Floor 13p · 2 filings · 20 docs
Cellar1p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/21/2021$1.3M—— → —$723/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAMES SCHAEFER ARCHITECT, P.C408/07/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
COMMERCIAL CAPITAL USA803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ELEPHANTS CUSTOM FURNITURGeneral Contractor1803/21/2026
BT'S PLUMBING AND HEATINGPlumbing507/08/2026
NICE PLUMBING CORPPlumbing307/08/2026
TIMOTHY MCDONALDElectrical203/21/2026
MAC ELECTL CONTR INC 001937General Contractor203/22/2026
BROOKLYN SOLARWORKS LLCGeneral Contractor103/22/2026
STEVEN BURKEElectrical103/21/2026
ARC ELECTRICAL & MECH CONElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ABEJA ENGINEERING PLLC7269208/07/2022
STRUCT. ENGINEERING INTEG4174208/07/2022
JAMES SCHAEFER ARCHITECT,3763208/06/2022
Building Lifecycle
All (97)Filed (4)Permit Issued (8)Signed Off (2)Violation (6)Inspection (5)Objection (42)Special Inspection (30)
01/27/2023
Signed off — Alteration
Filing for renovation of existing 2 family dwelling, including 113.5sf extension at 01 and 02. Including proposed rear steel deck at 01 and new skylight. Plumbing work filed under separate application B00533098-I1.
B00520059-I1
01/26/2023
Permit issued — Foundation
B00520059-I1-EA
01/26/2023
Permit issued — General Construction
B00520059-I1-FO
01/25/2023
Permit issued — General Construction
B00520059-I1-MS
01/25/2023
Permit issued — Mechanical Systems
B00520059-I1-ST
11/28/2022
Signed off — Alteration
Filing in conjunction with GC filing B00520059-I1.Kitchen and bathroom renovations for two family dwelling, including installation of 3 pc bathroom in cellar under restrictive declaration.
B00533098-I1
10/21/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/06/2022
Permit issued — Plumbing
B00533098-I1-PL
08/10/2022
Objection resolved — Addressed
08/10/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
08/10/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOHANN VELEZ
08/10/2022
Special inspection requirement — Masonry
JOHANN VELEZ
08/10/2022
Special inspection requirement — Concrete - Cast-In-Place
Chris Yiu
08/10/2022
Special inspection requirement — Mechanical Systems
JOHANN VELEZ
08/10/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chris Yiu
08/10/2022
Special inspection requirement — Structural Wood Frame
Chris Yiu
08/10/2022
Special inspection requirement — Preliminary
JOHANN VELEZ
08/10/2022
Special inspection requirement — Footing and Foundation
Chris Yiu
08/10/2022
Special inspection requirement — Fire-Resistance Rated Construction
JOHANN VELEZ
08/10/2022
Special inspection requirement — Energy Code Compliance Inspections
JOHANN VELEZ
08/10/2022
Special inspection requirement — Final
JOHANN VELEZ
08/10/2022
Special inspection requirement — Lighting controls
JOHANN VELEZ
08/10/2022
Special inspection requirement — Fenestration air leakage
JOHANN VELEZ
08/10/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
JOHANN VELEZ
08/10/2022
Special inspection requirement — Fenestration areas
JOHANN VELEZ
08/10/2022
Special inspection requirement — Interior lighting power
JOHANN VELEZ
08/10/2022
Special inspection requirement — Lighting in dwelling units
JOHANN VELEZ
08/09/2022
Objection raised — Scope
08/07/2022
Filed — Alteration
Filing for renovation of existing 2 family dwelling, including 113.5sf extension at 01 and 02. Including proposed rear steel deck at 01 and new skylight. Plumbing work filed under separate application B00533098-I1.
B00520059-P1
08/06/2022
Filed — Alteration
Filing in conjunction with GC filing B00520059-I1.Kitchen and bathroom renovations for two family dwelling, including installation of 3 pc bathroom in cellar under restrictive declaration.
B00533098-P1
08/06/2022
Special inspection requirement — Lighting controls
JOHANN VELEZ
08/06/2022
Special inspection requirement — Fenestration air leakage
JOHANN VELEZ
08/06/2022
Special inspection requirement — Interior lighting power
JOHANN VELEZ
08/06/2022
Special inspection requirement — Fenestration areas
JOHANN VELEZ
08/06/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
JOHANN VELEZ
08/06/2022
Special inspection requirement — Lighting in dwelling units
JOHANN VELEZ
07/25/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/25/2022
Special inspection requirement — Energy Code Compliance Inspections
JOHANN VELEZ
07/25/2022
Special inspection requirement — Final
JOHANN VELEZ
07/25/2022
Special inspection requirement — Fire-Resistance Rated Construction
JOHANN VELEZ
07/25/2022
Special inspection requirement — Footing and Foundation
Chris Yiu
07/25/2022
Special inspection requirement — Preliminary
JOHANN VELEZ
07/25/2022
Special inspection requirement — Structural Wood Frame
Chris Yiu
07/20/2022
Permit issued — Foundation
B00520059-I1-GC
07/13/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/13/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/13/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/20/2022
Violation issued (ECB, closed)
Unknown
04/15/2022
Violation issued (ECB, closed)
Construction
04/15/2022
Violation issued (ECB, closed)
Site Safety
04/15/2022
Violation issued (ECB, closed)
Construction
04/15/2022
Violation issued (ECB, closed)
Construction
04/15/2022
Violation issued (ECB, closed)
Construction
11/26/2021
Permit issued — General Construction
B00520059-I1-GC
10/18/2021
Permit issued — Plumbing
B00533098-I1-PL
07/07/2021
Objection raised — Other
07/07/2021
Objection resolved — Addressed
07/07/2021
Objection raised — Other
07/07/2021
Objection resolved — Addressed
07/07/2021
Objection raised — Other
Latest 60 of 97 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationSigned-offELEPHANTS CUSTOM FURNITUR01/26/2023
DOB NOWGeneral ConstructionSigned-offELEPHANTS CUSTOM FURNITUR01/26/2023
DOB NOWGeneral ConstructionSigned-offELEPHANTS CUSTOM FURNITUR01/25/2023
DOB NOWMechanical SystemsSigned-offELEPHANTS CUSTOM FURNITUR01/25/2023
DOB NOWPlumbingSigned-offNICE PLUMBING CORP10/06/2022
DOB NOWFoundationSigned-offELEPHANTS CUSTOM FURNITUR07/20/2022
DOB NOWGeneral ConstructionSigned-offELEPHANTS CUSTOM FURNITUR11/26/2021
DOB NOWPlumbingSigned-offBT'S PLUMBING AND HEATING10/18/2021
BISOTISSUEDBROOKLYN SOLARWORKS LLC11/18/2021
2 projects · most recent 12/08/2022
General Wiring
FiledStatusContractorScope
12/08/2022CompleteMAC ELECT'L CONTR. INC.General Wiring
07/15/2022CompleteBROOKYLN SOLARWORKS, LLC—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/21/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/25/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/13/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/13/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/13/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
08/10/2022Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
08/10/2022Fire-Resistant Penetrations and JointsJOHANN VELEZspecial
08/10/2022MasonryJOHANN VELEZspecial
08/10/2022Concrete - Cast-In-PlaceChris Yiuspecial
08/10/2022Mechanical SystemsJOHANN VELEZspecial
08/10/2022Structural Stability – Alterations of existing buildingsChris Yiuspecial
08/10/2022Structural Wood FrameChris Yiuprogress
08/10/2022PreliminaryJOHANN VELEZprogress
08/10/2022Footing and FoundationChris Yiuprogress
08/10/2022Fire-Resistance Rated ConstructionJOHANN VELEZprogress
08/10/2022Energy Code Compliance InspectionsJOHANN VELEZprogress
08/10/2022FinalJOHANN VELEZprogress
08/10/2022Lighting controlsJOHANN VELEZenergy_progress
08/10/2022Fenestration air leakageJOHANN VELEZenergy_progress
08/10/2022Fenestration and door U-factor and product ratingsJOHANN VELEZenergy_progress
08/10/2022Fenestration areasJOHANN VELEZenergy_progress
08/10/2022Interior lighting powerJOHANN VELEZenergy_progress
08/10/2022Lighting in dwelling unitsJOHANN VELEZenergy_progress
08/06/2022Lighting controlsJOHANN VELEZenergy_progress
08/06/2022Fenestration air leakageJOHANN VELEZenergy_progress
08/06/2022Interior lighting powerJOHANN VELEZenergy_progress
08/06/2022Fenestration areasJOHANN VELEZenergy_progress
08/06/2022Fenestration and door U-factor and product ratingsJOHANN VELEZenergy_progress
08/06/2022Lighting in dwelling unitsJOHANN VELEZenergy_progress
07/25/2022Energy Code Compliance InspectionsJOHANN VELEZprogress
Latest 25 of 36.
▾Documents — 71 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/01/2026B00533098-I1Request digital key ↗
09/01/2026B00533098-P1Request digital key ↗
08/14/2026B00520059-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
11/10/2022340828527Open ↗
11/17/2021340828527Open ↗
▸BISWORK PERMIT APPLICATION1
11/18/2021340828527Open ↗
▸Zoning, Tax Lot & Property Records8
▸DOB NOWRestrictive Declaration/Easement 14
08/14/2026B00520059-I1Open ↗
08/13/2026B00533098-I1Open ↗
08/13/2026B00533098-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram2
08/14/2026B00520059-I1Open ↗
08/13/2026B00520059-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/14/2026B00520059-I1Open ↗
08/13/2026B00520059-P1Open ↗
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature8
08/24/2026B00520059-I1Open ↗
08/24/2026B00520059-I1Open ↗
08/24/2026B00520059-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/24/2026B00520059-I1Open ↗
08/24/2026B00520059-I1Open ↗
08/24/2026B00520059-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00533098-I1Open ↗
09/01/2026B00533098-P1Open ↗
09/01/2026B00520059-I1Open ↗
Showing 3 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/17/2021340828527Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
11/18/2021340828527Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/01/2026B00533098-P1Open ↗
09/01/2026B00533098-I1Open ↗
08/14/2026B00520059-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/17/2021340828527Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/02/2022340828527Open ↗
11/17/2021340828527Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00533098-I1Open ↗
08/13/2026B00520059-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/02/2022340828527Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
12/05/2022340828527Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
11/17/2021340828527Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/02/2022340828527Open ↗
11/17/2021340828527Open ↗
▸DOB NOWSOIL REPORT2
08/14/2026B00520059-I1Open ↗
08/13/2026B00520059-P1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00520059-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00520059-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/05/2022340828527Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
12/05/2022340828527Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT2
12/02/2022340828527Open ↗
11/17/2021340828527Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026B00520059-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026B00520059-I1Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
11/22/2022340828527Open ↗
11/17/2021340828527Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/17/2021340828527Open ↗
▸Other Documents7
▸DOB NOWPlot Diagram2
08/14/2026B00520059-I1Open ↗
08/13/2026B00520059-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/14/2026B00520059-I1Open ↗
08/13/2026B00520059-P1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B00520059-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00520059-I1Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026B00520059-I1Open ↗