← Back
Multi-story retail building (2+)
1803 KINGS HIGHWAY
BROOKLYN · BIN 3182498
💬 Discuss this project
1925Year Built
2Stories
K2Building Class
R7AZoning
1,900 sfGross Floor Area
2Units
3 Open Violations 0 unresolved · 3 paperwork only ▸FDNY Report ↗
Multi-story retail building (2+) · Owner of record: HW 1-10 TRUST · 1,143 sf lot · 1.66 FAR built · Flood zone X
Locations of Work
Civil
Roof1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HW 1-10 TRUST303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LUGADI LLC104/06/2026
SERDAR CEYLAN ARCHITECT, PC107/31/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MCDONALD TIMOTHYElectrical103/21/2026
TIMOTHY MCDONALDElectrical103/21/2026
MKNK WASTE REMOVAL INCGeneral Contractor106/28/2026
Building Lifecycle
All (21)Filed (2)Permit Issued (1)Violation (3)Objection (12)Special Inspection (3)
06/10/2026
Permit issued — General Construction
B01262355-I1-GC
05/01/2026
Objection raised — Structural
05/01/2026
Objection raised — Zoning
05/01/2026
Objection raised — Structural
05/01/2026
Objection raised — Structural
05/01/2026
Objection raised — Inspections
05/01/2026
Objection raised — Structural
05/01/2026
Objection raised — Structural
05/01/2026
Objection raised — Scope
04/06/2026
Filed — Alteration
Job filling for the pasageway (5'-0"W x 6'-9"H) between 1801 and 1803 Kings Higway
B01382902-I1
04/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
04/03/2026
Special inspection requirement — Final
08/05/2025
Objection resolved — Addressed
08/05/2025
Objection resolved — Addressed
08/04/2025
Objection raised — Scope
08/04/2025
Objection raised — Structural
07/31/2025
Filed — Alteration
INSTALLATION OF AWNING ON THE 1ST FLOOR OF TWO STORY EXISTING COMMERCIAL BUILDING AS PER PLANS SUBMITTED. ALSO FILED AGAINTS THE AWNING VIOLATION: #39144655R.
B01262355-I1
07/28/2025
Special inspection requirement — Final
SERDAR CEYLAN
04/11/2025
Violation issued (ECB, open)
Construction
04/11/2025
Violation issued (ECB, open)
Unknown
04/11/2025
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMKNK WASTE REMOVAL INC06/10/2026
BISPLISSUEDDUMONT PLBG & HTG CORP08/28/2019
BISPLISSUEDPETER MICELI PLUMBING12/01/2017
BISOTISSUEDOZ BOSPH CONSTRUCTION COR11/28/2017
2 projects · most recent 04/10/2026
General Wiring
FiledStatusContractorScope
04/10/2026Permit IssuedGEMINI ELECTRIC CO., INC.General Wiring
11/24/2025CancelledGEMINI ELECTRIC CO., INC.General Wiring
1 project · most recent 04/06/2026
FiledStatusContractorScope
04/06/2026——2 scope_items
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
04/03/2026Structural Stability – Alterations of existing buildings—special
04/03/2026Final—progress
07/28/2025FinalSERDAR CEYLANprogress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026B01262355-I1Request digital key ↗
08/14/2026B01382902-I1Request digital key ↗
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION4
11/15/2019321677565Open ↗
01/17/2019321677565Open ↗
01/16/2019321677565Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
09/13/2019321677565Open ↗
12/04/2017321677565Open ↗
11/29/2017321677565Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
12/27/2018321677565Open ↗
▸Seals & Professional Certifications9
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
11/18/2019321677565Open ↗
11/18/2019321677565Open ↗
11/18/2019321677565Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026B01262355-I1Open ↗
08/17/2026B01382902-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
11/29/2017321677565Open ↗
▸BISProfessional and Owner Certification (POC3)1
11/29/2017321677565Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/25/2026B01262355-I1Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
01/17/2019321677565Open ↗
01/16/2019321677565Open ↗
11/29/2017321677565Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
09/13/2019321677565Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
11/29/2017321677565Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026B01262355-I1Open ↗
08/14/2026B01382902-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/29/2017321677565Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
11/18/2019321677565Open ↗
11/18/2019321677565Open ↗
11/29/2017321677565Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/18/2019321677565Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/18/2019321677565Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/18/2019321677565Open ↗
11/29/2017321677565Open ↗
▸Filing & Intake Forms4
▸BISBOROUGH INTAKE FORM2
11/18/2019321677565Open ↗
01/17/2019321677565Open ↗
▸BISADDITIONAL INFORMATION1
11/08/2019321677565Open ↗
▸BISEFILING COVER SHEET1
11/29/2017321677565Open ↗