← Back
Two stories - detached, small or mid-size
18-13 MENAHAN STREET
QUEENS · Ridgewood · BIN 4082040
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R6BZoning
1,675 sfGross Floor Area
1Units
0 Open Violations
Two stories - detached, small or mid-size · 2,500 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction63p · 1 filing · 20 docs
PenthouseUnder Construction70p · 1 filing · 20 docs
Floor 4Under Construction63p · 1 filing · 20 docs
Floor 3Under Construction66p · 1 filing · 20 docs
Floor 2Under Construction63p · 1 filing · 20 docs
Floor 1Under Construction61p · 1 filing · 20 docs
CellarUnder Construction67p · 1 filing · 20 docs
Site & exteriorUnder Construction68p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SAFELINE GROUP207/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MCHENERY TESTING LAB206/10/2026
KMA DESIGNS LLC112/30/2025
SHARON ENGINEERING, P.C811/11/2025
MELAMED ARCHITECT PC105/12/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING1403/21/2026
YK EXPEDITING403/21/2026
KMA DESIGNS LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B36 SERVICES INCGeneral Contractor707/08/2026
SAFELINE GROUP INCGeneral Contractor207/08/2026
FORSURE ELECTRIC NY INCElectrical103/22/2026
QUALITY PIPING, INCFire Protection107/08/2026
NESS MECHANICAL P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519111/11/2025
SHAHRISH SHUVO ENGINEERIN8524806/10/2025
Building Lifecycle
All (143)Filed (12)Permit Issued (12)Violation (1)Inspection (8)Objection (80)Special Inspection (30)
08/06/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
08/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/03/2026
Permit issued — Sidewalk Shed
Q01223124-S9-SH
06/11/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/11/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/10/2026
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
Q01414736-I1
06/10/2026
Permit issued — Supported Scaffold
Q01414736-I1-SF
05/26/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/08/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/06/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/04/2026
Filed — New Building
Proposed underpinning of the adjacent structure at 1815 Menahan Street for a new 4-story with penthouse multi family residential building as per plan, filed in conjunction with NB # Q01223124-I1.
Q01223124-S9
05/04/2026
Permit issued — Sidewalk Shed
Q01223124-S9-SH
05/04/2026
Permit issued — Sprinklers
Q01223124-S7-EW-SP
05/04/2026
Permit issued — Plumbing
Q01223124-S6-PL
05/01/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/27/2026
Permit issued — Foundation
Q01223124-S4-FO
03/25/2026
Permit issued — Foundation
Q01223124-S2-FO
03/24/2026
Permit issued — General Construction
Q01223124-I1-GC
03/23/2026
Permit issued — Construction Fence
Q01223124-S8-FN
03/20/2026
Permit issued — Mechanical Systems
Q01223124-S5-MS
03/20/2026
Permit issued — Structural
Q01223124-S1-ST
03/20/2026
Permit issued — Support of Excavation
Q01223124-S3-SE
12/30/2025
Filed — New Building
Proposed underpinning of the adjacent structure at 1815 Menahan Street for a new 4-story with penthouse multi family residential building as per plan, filed in conjunction with NB # Q01223124-I1.
Q01223124-S8
12/19/2025
Objection resolved — Addressed
12/18/2025
Special inspection requirement — Final
Shahrish Shuvo
12/18/2025
Special inspection requirement — Shutoff dampers
Shahrish Shuvo
12/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
Shahrish Shuvo
12/18/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Shahrish Shuvo
12/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
Shahrish Shuvo
12/18/2025
Special inspection requirement — Mechanical Systems
Shahrish Shuvo
12/18/2025
Special inspection requirement — Maintenance information
Shahrish Shuvo
12/17/2025
Special inspection requirement — Permanent certificate
Shahrish Shuvo
12/16/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/17/2025
Objection raised — Energy
11/14/2025
Objection raised — Energy
11/11/2025
Filed — New Building
Proposed underpinning of the adjacent structure at 1815 Menahan Street for a new 4-story with penthouse multi family residential building as per plan, filed in conjunction with NB # Q01223124-I1.
Q01223124-P1
11/10/2025
Objection resolved — Addressed
11/04/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Shahrish Shuvo
10/16/2025
Special inspection requirement — Seismic Resistance of Plumbing, Mechanical, Fuel Gas, and Electrical Components
Shahrish Shuvo
10/13/2025
Objection resolved — Addressed
10/13/2025
Objection resolved — Addressed
10/13/2025
Objection resolved — Addressed
10/09/2025
Objection resolved — Addressed
10/09/2025
Objection resolved — Addressed
09/23/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/15/2025
Objection resolved — Addressed
Latest 60 of 143 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedKTC DESIGN GROUP INC08/03/2026
DOB NOWSupported ScaffoldPermit IssuedSAFELINE GROUP INC06/10/2026
DOB NOWSidewalk ShedPermit IssuedSAFELINE GROUP INC05/04/2026
DOB NOWSprinklersPermit IssuedQUALITY PIPING, INC05/04/2026
DOB NOWPlumbingPermit IssuedNESS MECHANICAL P & H INC05/04/2026
DOB NOWFoundationPermit IssuedB36 SERVICES INC03/27/2026
DOB NOWFoundationPermit IssuedB36 SERVICES INC03/25/2026
DOB NOWGeneral ConstructionPermit IssuedB36 SERVICES INC03/24/2026
DOB NOWConstruction FencePermit IssuedB36 SERVICES INC03/23/2026
DOB NOWMechanical SystemsPermit IssuedB36 SERVICES INC03/20/2026
DOB NOWStructuralPermit IssuedB36 SERVICES INC03/20/2026
DOB NOWSupport of ExcavationPermit IssuedB36 SERVICES INC03/20/2026
1 project · most recent 05/04/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/04/2026Permit IssuedSAFELINE GROUP INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NAM2 41,000 BTU · Condensing Unit ×8
MXZ-SM60NAM2 66,000 BTU · Condensing Unit ×4
Ventilation
Greenheck USF-04-B6 200 CFM · Exhaust Fan ×2
1 project · most recent 05/04/2026
Sprinkler System
FiledStatusContractorScope
05/04/2026Permit IssuedQUALITY PIPING, INCSprinkler System
1 project · most recent 05/04/2026
Storm Water/Sanitary
FiledStatusContractorScope
05/04/2026Permit IssuedNESS MECHANICAL P & H INCStorm, Water/Sanitary
2 projects · most recent 05/01/2026
General Wiring
FiledStatusContractorScope
05/01/2026Permit IssuedRICHARD NEU—
12/19/2025Permit IssuedFORSURE ELECTRIC NY INCGeneral Wiring
1 project · most recent 05/04/2026
Steel Concrete
FiledStatusContractorScope
05/04/2026Permit IssuedSAFELINE GROUP INCSteel, Concrete
2 projects · most recent 06/10/2026
Scaffold Fence
FiledStatusContractorScope
06/10/2026Permit IssuedSAFELINE GROUP INCScaffold
05/04/2026Permit IssuedSAFELINE GROUP INCFence
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
08/06/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/11/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/11/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/26/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/08/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/06/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/01/2026Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 50
DateRequirementInspectorRole
12/18/2025FinalShahrish Shuvoprogress
12/18/2025Shutoff dampersShahrish Shuvoenergy_progress
12/18/2025HVAC-R and service water heating system controlsShahrish Shuvoenergy_progress
12/18/2025HVAC-R and service water piping design and insulationShahrish Shuvoenergy_progress
12/18/2025HVAC-R and service water heating equipmentShahrish Shuvoenergy_progress
12/18/2025Mechanical SystemsShahrish Shuvospecial
12/18/2025Maintenance informationShahrish Shuvoenergy_progress
12/17/2025Permanent certificateShahrish Shuvoenergy_progress
11/04/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationShahrish Shuvospecial
10/16/2025Seismic Resistance of Plumbing, Mechanical, Fuel Gas, and Electrical ComponentsShahrish Shuvospecial
09/15/2025PreliminaryShahrish Shuvoprogress
09/15/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationShahrish Shuvospecial
08/29/2025MeteringShahrish Shuvoenergy_progress
08/29/2025Lighting in dwelling unitsShahrish Shuvoenergy_progress
08/29/2025Exterior lighting powerShahrish Shuvoenergy_progress
05/22/2025Seismic Isolation SystemsShahrish Shuvospecial
05/22/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
05/22/2025Post-installed AnchorsShahrish Shuvospecial
05/22/2025Energy Code Compliance InspectionsShahrish Shuvoprogress
05/22/2025Maintenance informationShahrish Shuvoenergy_progress
05/22/2025HVAC-R and service water heating equipmentShahrish Shuvoenergy_progress
05/22/2025HVAC-R and service water piping design and insulationShahrish Shuvoenergy_progress
05/22/2025HVAC-R and service water heating system controlsShahrish Shuvoenergy_progress
05/22/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
05/22/2025Post-installed AnchorsShahrish Shuvospecial
Latest 25 of 50.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/17/2026Q01223124-S1Request digital key ↗
08/17/2026Q01223124-S9Request digital key ↗
08/17/2026Q01223124-S8Request digital key ↗
Showing 3 of 12 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01223124-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01223124-I1Open ↗
▸Seals & Professional Certifications29
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/17/2026Q01223124-S9Open ↗
08/17/2026Q01223124-S5Open ↗
08/16/2026Q01414736-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026Q01223124-S6Open ↗
09/01/2026Q01223124-S6Open ↗
08/28/2026Q01223124-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026Q01223124-S6Open ↗
08/28/2026Q01223124-S2Open ↗
08/28/2026Q01223124-S2Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
02/26/2026440825305Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/26/2026440825305Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q01223124-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01223124-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q01223124-I1Open ↗
▸Inspections & Test Reports5
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q01223124-S4Open ↗
08/13/2026Q01223124-S2Open ↗
▸DOB NOWSOIL REPORT2
08/13/2026Q01223124-S2Open ↗
08/13/2026Q01223124-S4Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/26/2026440825305Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01223124-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01223124-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01223124-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01223124-S3Open ↗