← Back
Two family converted from one family
1818 EAST 17 STREET
BROOKLYN · Madison · BIN 3184028
💬 Discuss this project
1925Year Built
3Stories
B3Building Class
R5BZoning
2,698 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: 1818 EAST 17TH STREET · 2,000 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionEquipmentGeneral
Roof47p · 3 filings · 20 docs
Floor 345p · 3 filings · 20 docs
Floor 247p · 3 filings · 20 docs
Floor 142p · 3 filings · 20 docs
Cellar47p · 3 filings · 20 docs
Site & exterior8p · 2 filings · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EMPIRE STATE ELECTRICAL CORP2203/22/2026
RISE DEVELOPMENT PARTNERS807/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/10/2022$810K—— → —$300/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LAURIA ASSOCIATES205/10/2024
YAKER ENGINEERING, P.C.712/18/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BANJI ARCHITECT PC703/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RISE DEVELOPMENT PARTNERSGeneral Contractor1307/08/2026
EMPIRE STATE ELECTL CORPElectrical103/22/2026
RITE WAY HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LAURIA ASSOCIATES7570705/10/2024
Building Lifecycle
All (118)Filed (9)Permit Issued (8)Signed Off (3)Inspection (8)Objection (60)Special Inspection (30)
07/16/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/14/2024
Signed off — Alteration
ALTERATION APPLICATION IN CONJUNCTION WITH B00746691-I1, FILED FOR PROPOSED PARTIAL DEMO, STRUCTURAL AND MINOR FOUNDATION WORK. PROJECT INVOLVES PROPOSED INTERIOR RENOVATION AND 1 STORY VERTICAL ENLARGEMENT FOR AN EXISTING 2 FAMILY DWELLING
B00798739-I1
05/14/2024
Special inspection requirement — Final
EDWARD LAURIA
05/14/2024
Special inspection requirement — Footing and Foundation
EDWARD LAURIA
05/14/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
EDWARD LAURIA
05/14/2024
Special inspection requirement — Structural Steel - High Strength Bolting
EDWARD LAURIA
05/14/2024
Special inspection requirement — Structural Steel - Details
EDWARD LAURIA
05/14/2024
Special inspection requirement — Concrete - Cast-In-Place
EDWARD LAURIA
05/14/2024
Special inspection requirement — Structural Steel - Welding
EDWARD LAURIA
05/14/2024
Special inspection requirement — Underpinning
EDWARD LAURIA
05/14/2024
Special inspection requirement — Structural Cold-Formed Steel
EDWARD LAURIA
05/14/2024
Special inspection requirement — Masonry
EDWARD LAURIA
05/10/2024
Filed — Alteration
ALTERATION APPLICATION IN CONJUNCTION WITH B00746691-I1, FILED FOR PROPOSED PARTIAL DEMO, STRUCTURAL AND MINOR FOUNDATION WORK. PROJECT INVOLVES PROPOSED INTERIOR RENOVATION AND 1 STORY VERTICAL ENLARGEMENT FOR AN EXISTING 2 FAMILY DWELLING
B00798739-P1
04/18/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/11/2024
Special inspection requirement — Insulation placement and R values
EDWARD LAURIA
01/11/2024
Special inspection requirement — Maintenance information
EDWARD LAURIA
01/11/2024
Special inspection requirement — Shutoff dampers
EDWARD LAURIA
01/11/2024
Special inspection requirement — Interior lighting power
EDWARD LAURIA
01/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
EDWARD LAURIA
01/11/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
EDWARD LAURIA
01/11/2024
Special inspection requirement — Mechanical Systems
EDWARD LAURIA
01/11/2024
Special inspection requirement — Fire-Resistance Rated Construction
EDWARD LAURIA
01/11/2024
Special inspection requirement — Final
EDWARD LAURIA
01/11/2024
Special inspection requirement — Energy Code Compliance Inspections
EDWARD LAURIA
01/11/2024
Special inspection requirement — HVAC-R and service water heating equipment
EDWARD LAURIA
01/11/2024
Special inspection requirement — HVAC-R and service water heating system controls
EDWARD LAURIA
01/11/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
EDWARD LAURIA
01/11/2024
Special inspection requirement — Lighting controls
EDWARD LAURIA
12/18/2023
Filed — Alteration CO
Alteration CO application filed for interior renovation and 1 story vertical enlargement for an existing 2 family dwelling in conjunction with plumbing application #B00743913-I1 and mechanical work to be filed under this application.
B00746691-P2
12/08/2023
Signed off — Alteration
This application is being filed for new installation of plumbing fixtures and sprinkler heads as per AC.28-401.3. No change in Use or Occupancy.
B00743913-I1
11/29/2023
Special inspection requirement — Lighting controls
EDWARD LAURIA
11/29/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
EDWARD LAURIA
11/29/2023
Special inspection requirement — Shutoff dampers
EDWARD LAURIA
11/29/2023
Special inspection requirement — HVAC-R and service water heating equipment
EDWARD LAURIA
11/29/2023
Special inspection requirement — HVAC-R and service water heating system controls
EDWARD LAURIA
11/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
EDWARD LAURIA
11/24/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/15/2023
Signed off — Alteration
Application is filed for Temporary 8' High Construction Solid Fence. No change in use, egress occupancy.
B00754997-I1
11/15/2023
Permit issued — General Construction
B00746691-I1-GC
11/13/2023
Permit issued — General Construction
B00746691-I1-MS
10/10/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/25/2023
Objection resolved — Addressed
09/08/2023
Objection resolved — Addressed
08/31/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/17/2023
Objection resolved — Addressed
08/02/2023
Objection raised — Scope
07/27/2023
Objection resolved — Addressed
07/11/2023
Objection resolved — Addressed
07/11/2023
Objection resolved — Addressed
06/27/2023
Objection raised — Other
06/27/2023
Objection raised — Other
06/27/2023
Objection raised — Scope
06/27/2023
Objection raised — Scope
06/26/2023
Objection raised — Scope
06/26/2023
Objection raised — Scope
06/26/2023
Objection raised — Scope
06/21/2023
Filed — Alteration
This application is being filed for new installation of plumbing fixtures and sprinkler heads as per AC.28-401.3. No change in Use or Occupancy.
B00743913-P2
06/21/2023
Filed — Alteration CO
Alteration CO application filed for interior renovation and 1 story vertical enlargement for an existing 2 family dwelling in conjunction with plumbing application #B00743913-I1 and mechanical work to be filed under this application.
B00746691-P1
06/07/2023
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
Latest 60 of 118 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedRISE DEVELOPMENT PARTNERS11/15/2023
DOB NOWGeneral ConstructionSigned-offRISE DEVELOPMENT PARTNERS11/13/2023
DOB NOWGeneral ConstructionSigned-offRISE DEVELOPMENT PARTNERS06/04/2023
DOB NOWPlumbingSigned-offLS PLUMBING CORP03/10/2023
DOB NOWMechanical SystemsPermit IssuedRISE DEVELOPMENT PARTNERS01/04/2023
DOB NOWConstruction FenceSigned-offRISE DEVELOPMENT PARTNERS01/04/2023
DOB NOWMechanical SystemsPermit IssuedRISE DEVELOPMENT PARTNERS12/29/2022
DOB NOWConstruction FenceSigned-offRISE DEVELOPMENT PARTNERS06/22/2022
1 project · most recent 12/18/2023
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/18/2023Permit IssuedRISE DEVELOPMENT PARTNERSHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MLZ-KP09NA 21,000 BTU · Fan Coil Indoor ×12
MLZ-KP12NA 27,400 BTU · Vrf Indoor ×10
MXZ-3C24NAHZ3-U11 54,200 BTU · Condensing Unit ×2
MXZ-2C20NAHZ4-U1 45,500 BTU · Condensing Unit ×1
MXZ-SM36NAMHZ-U1 78,000 BTU · Condensing Unit ×1
MXZ-5C42NA 85,500 BTU · Heat Pump Outdoor ×3
Ventilation
Panasonic FV-0511VKS2 110 CFM · Exhaust Fan ×11
FV-08VKL3 80 CFM · Exhaust Fan ×8
FV-15VKL3 120 CFM · Exhaust Fan ×3
2 projects · most recent 07/07/2023
General Wiring
FiledStatusContractorScope
07/07/2023CompleteEMPIRE STATE ELECTL CORPGeneral Wiring
02/16/2023CompleteEMPIRE STATE ELECTL CORP—
1 project · most recent 12/18/2023
FiledStatusContractorScope
12/18/2023Permit IssuedRISE DEVELOPMENT PARTNERS1 scope_items
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
07/16/2024Pass-Final CND-Occupancy InspectionPassView ↗
04/18/2024Pass-Final CND-Occupancy InspectionPassView ↗
11/24/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/10/2023Fail-Final General Construction Non-Directive 14FailView ↗
06/07/2023Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
06/07/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/11/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/22/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 60
DateRequirementInspectorRole
05/14/2024FinalEDWARD LAURIAprogress
05/14/2024Footing and FoundationEDWARD LAURIAprogress
05/14/2024Structural Stability – Alterations of existing buildingsEDWARD LAURIAspecial
05/14/2024Structural Steel - High Strength BoltingEDWARD LAURIAspecial
05/14/2024Structural Steel - DetailsEDWARD LAURIAspecial
05/14/2024Concrete - Cast-In-PlaceEDWARD LAURIAspecial
05/14/2024Structural Steel - WeldingEDWARD LAURIAspecial
05/14/2024UnderpinningEDWARD LAURIAspecial
05/14/2024Structural Cold-Formed SteelEDWARD LAURIAspecial
05/14/2024MasonryEDWARD LAURIAspecial
01/11/2024Insulation placement and R valuesEDWARD LAURIAenergy_progress
01/11/2024Maintenance informationEDWARD LAURIAenergy_progress
01/11/2024Shutoff dampersEDWARD LAURIAenergy_progress
01/11/2024Interior lighting powerEDWARD LAURIAenergy_progress
01/11/2024Fire-Resistant Penetrations and JointsEDWARD LAURIAspecial
01/11/2024Structural Stability – Alterations of existing buildingsEDWARD LAURIAspecial
01/11/2024Mechanical SystemsEDWARD LAURIAspecial
01/11/2024Fire-Resistance Rated ConstructionEDWARD LAURIAprogress
01/11/2024FinalEDWARD LAURIAprogress
01/11/2024Energy Code Compliance InspectionsEDWARD LAURIAprogress
01/11/2024HVAC-R and service water heating equipmentEDWARD LAURIAenergy_progress
01/11/2024HVAC-R and service water heating system controlsEDWARD LAURIAenergy_progress
01/11/2024HVAC-R and service water piping design and insulationEDWARD LAURIAenergy_progress
01/11/2024Lighting controlsEDWARD LAURIAenergy_progress
11/29/2023Lighting controlsEDWARD LAURIAenergy_progress
Latest 25 of 60.
▾Documents — 81 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/29/2026B00754997-I1Request digital key ↗
08/28/2026B00798739-P1Request digital key ↗
08/26/2026B00746691-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B00746691-I1Open ↗
08/13/2026B00746691-P1Open ↗
08/13/2026B00746691-P2Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026B00746691-P2Open ↗
08/13/2026B00746691-I1Open ↗
08/13/2026B00746691-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00746691-I1Open ↗
▸Seals & Professional Certifications27
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/29/2026B00754997-I1Open ↗
08/29/2026B00743913-P2Open ↗
08/29/2026B00743913-P1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/31/2026B00746691-P1Open ↗
08/28/2026B00798739-I1Open ↗
08/28/2026B00798739-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
08/31/2026B00746691-P1Open ↗
08/31/2026B00746691-P1Open ↗
08/28/2026B00798739-I1Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
07/03/2023340875592Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/03/2023340875592Open ↗
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist3
08/13/2026B00746691-I1Open ↗
08/13/2026B00746691-P1Open ↗
08/13/2026B00746691-P2Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00746691-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00746691-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00746691-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/26/2026B00746691-P2Open ↗
08/26/2026B00746691-I1Open ↗
08/15/2026B00746691-P1Open ↗
Showing 3 of 8 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00746691-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
07/03/2023340875592Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
07/03/2023340875592Open ↗
07/03/2023340875592Open ↗
▸BISEFILING COVER SHEET1
07/03/2023340875592Open ↗
▸Other Documents19
▸DOB NOWSite Survey: Initial5
08/13/2026B00798739-P1Open ↗
08/13/2026B00746691-I1Open ↗
08/13/2026B00746691-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/13/2026B00798739-P1Open ↗
08/13/2026B00746691-P1Open ↗
08/13/2026B00746691-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlot Diagram5
08/13/2026B00746691-P1Open ↗
08/13/2026B00746691-P2Open ↗
08/13/2026B00746691-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification3
08/26/2026B00746691-P2Open ↗
08/26/2026B00746691-I1Open ↗
08/15/2026B00746691-P1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00746691-I1Open ↗