← Back
One story - permanent living quarter
182-06 69 AVENUE
QUEENS · BIN 4153593
💬 Discuss this project
1950Year Built
1.5Stories
A2Building Class
R2AZoning
1,219 sfGross Floor Area
1Units
3 Open Violations 0 unresolved · 3 paperwork only ▸FDNY Report ↗
One story - permanent living quarter · Owner of record: 182-06 69 AVE LLC · 4,000 sf lot · 0.3 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingCivil
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 19 docs
Floor 2Under Construction8p · 1 filing · 19 docs
Floor 1Under Construction8p · 1 filing · 19 docs
CellarUnder Construction8p · 1 filing · 19 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/06/2025$900K—Private party → 182-06 69 AVE LLC$738/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AA BLDG & INSP SVC LLC406/10/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Younes Abouyaala PE103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOHN EVAN CONTRACTING CORGeneral Contractor109/23/2026
ARCO PLBG AND HTG INCPlumbing109/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519202/13/2026
Building Lifecycle
All (9)Filed (4)Permit Issued (2)Violation (3)
09/22/2026
Permit issued — Structural
Q01236720-I1-GC-CX
09/21/2026
Permit issued — Plumbing
Q01236720-S1-PL
06/10/2026
Filed — Alteration
PROPOSED NEW ONE STORY EXTENTION TO EXISTING ONE FAMILY HOUSE CREATING NEW FAMILY ROOM TO FIRST FL AND NEW BALCONY TO SECOND FL.. RESOLVE ECB VIOLATIONS# 34456518L & 35442069Y.
Q01236720-P2
06/02/2026
Filed — Alteration
PROPOSED NEW ONE STORY EXTENTION TO EXISTING ONE FAMILY HOUSE CREATING NEW FAMILY ROOM TO FIRST FL AND NEW BALCONY TO SECOND FL.. RESOLVE ECB VIOLATIONS# 34456518L & 35442069Y.
Q01236720-P1
03/20/2026
Violation issued (ECB, open)
Construction
02/13/2026
Filed — Alteration
PROPOSED NEW ONE STORY EXTENTION TO EXISTING ONE FAMILY HOUSE CREATING NEW FAMILY ROOM TO FIRST FL AND NEW BALCONY TO SECOND FL.. RESOLVE ECB VIOLATIONS# 34456518L & 35442069Y.
Q01236720-S1
07/03/2025
Filed — Alteration
PROPOSED NEW ONE STORY EXTENTION TO EXISTING ONE FAMILY HOUSE CREATING NEW FAMILY ROOM TO FIRST FL AND NEW BALCONY TO SECOND FL.. RESOLVE ECB VIOLATIONS# 34456518L & 35442069Y.
Q01236720-I1
05/19/2021
Violation issued (ECB, open)
Zoning
12/10/2004
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedJOHN EVAN CONTRACTING COR09/22/2026
DOB NOWPlumbingPermit IssuedARCO PLBG AND HTG INC09/21/2026
1 project · most recent 06/10/2026
Wood
FiledStatusContractorScope
06/10/2026Permit IssuedJOHN EVAN CONTRACTING CORWood
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
06/11/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
06/05/2025Concrete - Cast-In-PlaceYounes Abouyaalaspecial
06/05/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
06/05/2025MasonryYounes Abouyaalaspecial
06/05/2025Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
06/05/2025Subgrade InspectionsYounes Abouyaalaspecial
06/05/2025Subsurface Investigations (Borings/Test Pits)—special
06/05/2025Final—progress
06/05/2025Footing and Foundation—progress
06/05/2025Energy Code Compliance Inspections—progress
06/05/2025Fire-Resistance Rated Construction—progress
06/05/2025Structural Wood Frame—progress
06/05/2025Insulation placement and R values—energy_progress
06/05/2025Air barrier - visual inspection—energy_progress
06/05/2025Protection of exposed foundation insulation—energy_progress
06/05/2025Interior lighting power—energy_progress
06/05/2025Fenestration air leakage—energy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/16/2026Q01236720-P1Request digital key ↗
08/16/2026Q01236720-I1Request digital key ↗
08/16/2026Q01236720-P2Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/16/2026Q01236720-I1Open ↗
08/13/2026Q01236720-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/16/2026Q01236720-S1Open ↗
08/16/2026Q01236720-I1Open ↗
08/16/2026Q01236720-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026Q01236720-S1Open ↗
08/24/2026Q01236720-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026Q01236720-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01236720-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01236720-I1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q01236720-I1Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026Q01236720-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01236720-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q01236720-I1Open ↗