← Back
One story - permanent living quarter
182-17 69 AVENUE
QUEENS · BIN 4153175
💬 Discuss this project
1945Year Built
1.5Stories
A2Building Class
R2AZoning
1,398 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · 4,000 sf lot · 0.35 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KING DAVID ARCHITECTURE PC109/11/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KING DAVID ARCHITECTURE203/21/2026
Building Lifecycle
All (14)Filed (1)Violation (1)Objection (12)
04/24/2026
Objection resolved — Addressed
04/07/2026
Objection resolved — Addressed
04/07/2026
Objection resolved — Addressed
04/07/2026
Objection resolved — Open
04/03/2026
Objection resolved — Addressed
01/13/2026
Objection resolved — Resolved
10/17/2025
Objection raised — Admin
10/17/2025
Objection raised — Structural
10/17/2025
Objection raised — Structural
10/17/2025
Objection raised — Zoning
10/17/2025
Objection raised — Structural
10/17/2025
Objection raised — Scope
09/11/2025
Filed — Alteration CO
INTERIOR RENOVATION OF AN EXISTING 1 FAMILY 1 1/2 STORY FRAME BUILDING W/ ATTIC & CELLAR. PROPOSED TO CONVERT ATTIC INTO 2ND FL, EXISTING WALLS AT ATTIC TO BE FULL HEIGHT. PROPOSED 2 STORY FRONT EXTENSION.
Q01273594-I1
01/22/2009
Violation issued (ECB, closed)
Unknown
Nothing on file for this building.
1 project · most recent 09/11/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/11/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-FS09NA 9,000 BTU · Heat Pump Outdoor ×4
MSZ-FS12NA 12,000 BTU · Heat Pump Outdoor ×2
MSZ-FS18NA 18,000 BTU · Heat Pump Outdoor ×1
MXZ-4C36NAHZ 36,000 BTU · Condensing Unit ×1
MXZ-5C42NA3 42,000 BTU · Condensing Unit ×1
Ventilation
Panasonic RG-T810LA 80 CFM · Exhaust Fan ×5
FV-15VQ5 150 CFM · Exhaust Fan ×1
Nothing on file for this building.
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026Q01273594-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
03/23/2009410238639Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/19/2026Q01273594-I1Open ↗
08/13/2026Q01273594-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/19/2026Q01273594-I1Open ↗
▸Seals & Professional Certifications2
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
03/23/2009410238639Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01273594-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/19/2026Q01273594-I1Open ↗
08/13/2026Q01273594-I1Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
03/23/2009410238639Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01273594-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
03/23/2009410238639Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
03/23/2009410238639Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
03/23/2009410238639Open ↗
▸Other Documents4
▸DOB NOWPlot Diagram1
08/13/2026Q01273594-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01273594-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01273594-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01273594-I1Open ↗