← Back
Two family converted from one family
182-29 143 AVENUE
💬 Discuss this project
1935Year Built
2Stories
B3Building Class
R3AZoning
2,364 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Attic5p · 1 filing · 20 docs
Floor 25p · 1 filing · 20 docs
Floor 15p · 1 filing · 20 docs
Cellar13p · 1 filing · 20 docs
Site & exterior75p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BAYVIEW HOMES CORP1903/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/29/2022$1.3M—BAYVIEW HOMES NY CORP → Private party$546/sf building
02/03/2021$440K—— → —$186/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.605/24/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW FAMILY HOMES & BUILDINGGeneral Contractor603/21/2026
ALL PRO PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781505/24/2022
Building Lifecycle
All (56)Filed (6)Permit Issued (3)Signed Off (2)Violation (1)Inspection (6)Objection (8)Special Inspection (30)
11/15/2022
Signed off — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-S1
11/05/2022
Signed off — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-S2
06/01/2022
Special inspection requirement — Fire-Resistance Rated Construction
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Ventilation and air distribution system
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Structural Wood Frame
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — HVAC-R and service water heating equipment
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Subgrade Inspections
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
06/01/2022
Special inspection requirement — Mechanical Systems
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Footing and Foundation
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Duct leakage testing, insulation and design
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Electric vehicle service equipment requirements
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Metering
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Masonry
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Structural Steel - High Strength Bolting
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Heating Systems
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Concrete - Cast-In-Place
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Structural Steel - Details
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Final
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Interior lighting power
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Insulation placement and R values
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Permanent certificate
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Air barrier - visual inspection
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Fenestration air leakage
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — HVAC-R and service water heating system controls
CHRISTIAN LOZADA
06/01/2022
Special inspection requirement — Fenestration areas
CHRISTIAN LOZADA
05/24/2022
Filed — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-P3
05/18/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/12/2022
Filed — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-P2
04/12/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/22/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/22/2021
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/22/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/22/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/03/2021
Permit issued — Plumbing
Q00517874-S1-PL
10/21/2021
Filed — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-P1
07/30/2021
Permit issued — Construction Fence
Q00517874-S2-FN
07/30/2021
Permit issued — Earth Work
Q00517874-I1-GC-CX
07/20/2021
Filed — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-S1
07/12/2021
Filed — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-S2
06/28/2021
Objection raised — Other
06/28/2021
Objection resolved — Addressed
06/28/2021
Objection raised — Scope
06/28/2021
Objection resolved — Addressed
06/28/2021
Objection raised — Admin
06/28/2021
Objection resolved — Addressed
06/28/2021
Objection raised — Scope
06/28/2021
Objection resolved — Addressed
06/21/2021
Filed — Alteration CO
THIS APPLICATION IS FILED FOR PLUMBING AND GAS PIPING WORK IN CONJUNCTIONWITH DOB NOW APPLICATION # Q00517874-I1.
Q00517874-I1
08/19/1995
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offALL PRO PLBG & HTG INC11/03/2021
DOB NOWConstruction FenceSigned-offNEW FAMILY HOMES & BUILDI07/30/2021
DOB NOWEarth WorkPermit IssuedNEW FAMILY HOMES & BUILDI07/30/2021
1 project · most recent 05/24/2022
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/24/2022Permit IssuedNEW FAMILY HOMES & BUILDIAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Fujitsu F03613CSJNAA 36,000 BTU · Condensing Unit ×3
F06013CSJNAA 60,000 BTU · Condensing Unit ×3
Heating
Fujitsu FF100215TS92M 100,000 BTU · Furnace ×1
FF75174CS80M 80,000 BTU · Furnace ×3
FF1002157S92M 100,000 BTU · Furnace ×2
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×15
Delta Breeze SMT150 150 CFM · Exhaust Fan ×6
2 projects · most recent 12/02/2021
General Wiring
FiledStatusContractorScope
12/02/2021CompleteAYYUB ELECTRIC CORPGeneral Wiring
05/16/2019CompleteALL WAYS ELECTRIC CORP.WGeneral Wiring
1 project · most recent 05/24/2022
Steel Wood
FiledStatusContractorScope
05/24/2022Signed-offALL PRO PLBG & HTG INCSteel, Wood
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
05/18/2022Pass-Final CND-Occupancy InspectionPassView ↗
04/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/22/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/22/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/22/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/22/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 94
DateRequirementInspectorRole
06/01/2022MasonryCHRISTIAN LOZADAspecial
06/01/2022Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
06/01/2022Subgrade InspectionsCHRISTIAN LOZADAspecial
06/01/2022Structural Steel - High Strength BoltingCHRISTIAN LOZADAspecial
06/01/2022Heating SystemsCHRISTIAN LOZADAspecial
06/01/2022Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
06/01/2022Structural Stability – Alterations of existing buildingsCHRISTIAN LOZADAspecial
06/01/2022Excavations - Sheeting, Shoring, and BracingCHRISTIAN LOZADAspecial
06/01/2022Concrete - Cast-In-PlaceCHRISTIAN LOZADAspecial
06/01/2022Mechanical SystemsCHRISTIAN LOZADAspecial
06/01/2022Structural Steel - DetailsCHRISTIAN LOZADAspecial
06/01/2022FinalCHRISTIAN LOZADAprogress
06/01/2022Footing and FoundationCHRISTIAN LOZADAprogress
06/01/2022Structural Wood FrameCHRISTIAN LOZADAprogress
06/01/2022Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
06/01/2022Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
06/01/2022Interior lighting powerCHRISTIAN LOZADAenergy_progress
06/01/2022Duct leakage testing, insulation and designCHRISTIAN LOZADAenergy_progress
06/01/2022Insulation placement and R valuesCHRISTIAN LOZADAenergy_progress
06/01/2022Permanent certificateCHRISTIAN LOZADAenergy_progress
06/01/2022Electric vehicle service equipment requirementsCHRISTIAN LOZADAenergy_progress
06/01/2022Fenestration and door U-factor and product ratingsCHRISTIAN LOZADAenergy_progress
06/01/2022Air barrier - visual inspectionCHRISTIAN LOZADAenergy_progress
06/01/2022Fenestration air leakageCHRISTIAN LOZADAenergy_progress
06/01/2022MeteringCHRISTIAN LOZADAenergy_progress
Latest 25 of 94.
▾Documents — 78 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/26/2026Q00517874-S2Request digital key ↗
08/26/2026Q00517874-S1Request digital key ↗
08/26/2026Q00517874-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
08/11/2021440580417Open ↗
01/23/2020440580417Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026Q00517874-I1Open ↗
08/13/2026Q00517874-P1Open ↗
08/13/2026Q00517874-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00517874-I1Open ↗
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature7
09/14/2026Q00517874-I1Open ↗
09/14/2026Q00517874-I1Open ↗
08/28/2026Q00517874-S2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/14/2026Q00517874-I1Open ↗
09/14/2026Q00517874-I1Open ↗
08/24/2026Q00517874-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/26/2026Q00517874-S2Open ↗
08/26/2026Q00517874-S1Open ↗
08/26/2026Q00517874-I1Open ↗
Showing 3 of 6 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
01/23/2020440580417Open ↗
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist4
08/13/2026Q00517874-P2Open ↗
08/13/2026Q00517874-P1Open ↗
08/13/2026Q00517874-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00517874-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00517874-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00517874-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/26/2026Q00517874-S1Open ↗
08/26/2026Q00517874-P1Open ↗
08/26/2026Q00517874-S2Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
02/25/2020440580417Open ↗
02/04/2020440580417Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026Q00517874-S1Open ↗
08/13/2026Q00517874-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
02/25/2020440580417Open ↗
▸Inspections & Test Reports9
▸DOB NOWSOIL REPORT4
08/13/2026Q00517874-P2Open ↗
08/13/2026Q00517874-P1Open ↗
08/13/2026Q00517874-P3Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY3
03/13/2020440580417Open ↗
03/13/2020440580417Open ↗
02/25/2020440580417Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00517874-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00517874-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/11/2021440580417Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
02/25/2020440580417Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
02/25/2020440580417Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
01/23/2020440580417Open ↗
▸Other Documents14
▸DOB NOWPlot Diagram4
08/13/2026Q00517874-I1Open ↗
08/13/2026Q00517874-P1Open ↗
08/13/2026Q00517874-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSURVEY: INITIAL4
08/13/2026Q00517874-P1Open ↗
08/13/2026Q00517874-I1Open ↗
08/13/2026Q00517874-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026Q00517874-I1Open ↗
08/13/2026Q00517874-P2Open ↗
08/13/2026Q00517874-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026Q00517874-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00517874-I1Open ↗