← Back
Two family frame
182-37 89 AVENUE
QUEENS · Jamaica · BIN 4212423
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R4-1Zoning
2,060 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 2,442 sf lot · 0.84 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Cellar2p · 1 filing · 5 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/10/2019$875K—Private party → Private party$425/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHRAF CORP104/15/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SHEIKH EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOHNNY'S P&H CONTRAC INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASHRAF CORPORATION1973104/15/2021
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Violation (3)Inspection (1)Special Inspection (1)
08/25/2021
Signed off — Alteration
Q00492449-I1
06/18/2021
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/12/2021
Permit issued — Plumbing
Q00492449-I1-PL
04/15/2021
Filed — Alteration
Q00492449-I1
03/24/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
AKM HOQUE
07/30/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/12/2011
Violation issued (ECB, closed)
Unknown
11/26/2011
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOHNNY NANHU05/12/2021
BISOTISSUEDDNS FINE BUILDERS INC10/22/2020
BISOTISSUEDDNS FINE BUILDERS INC09/29/2020
BISOTISSUEDM&M CONTRACTORS GROUP INC03/06/2020
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
06/18/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
03/24/2021Fire-Resistant Penetrations and JointsAKM HOQUEspecial
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/27/2026Q00492449-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
06/10/2021421944294Open ↗
06/07/2021421944294Open ↗
03/17/2020421944294Open ↗
▸BISWORK PERMIT APPLICATION2
10/19/2020421944294Open ↗
03/14/2020421944294Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWRestrictive Declaration/Easement 11
08/13/2026Q00492449-I1Open ↗
▸Seals & Professional Certifications5
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
03/07/2020421944294Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/07/2020421944294Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/07/2020421944294Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00492449-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q00492449-I1Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
03/07/2020421944294Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/07/2020421944294Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00492449-I1Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
03/07/2020421944294Open ↗
03/07/2020421944294Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/16/2021421944294Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/16/2021421944294Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
06/16/2021421944294Open ↗
06/16/2021421944294Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION2
10/19/2020421944294Open ↗
03/11/2020421944294Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
06/16/2021421944294Open ↗
03/07/2020421944294Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
06/10/2021421944294Open ↗
03/14/2020421944294Open ↗
▸BISEFILING COVER SHEET1
03/07/2020421944294Open ↗
▸BISBOROUGH INTAKE FORM1
10/19/2020421944294Open ↗