← Back
One story - permanent living quarter
183-41 ELMIRA AVENUE
QUEENS · St. Albans · BIN 4220452
💬 Discuss this project
1945Year Built
1.5Stories
A2Building Class
R2Zoning
1,260 sfGross Floor Area
1Units
One story - permanent living quarter · 4,000 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
Architecture
Cellar1p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASKON ARCHITECTS, P.C.104/02/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CA CONSTRUCTION INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASKON ARCHITECT, P.C.3596104/02/2022
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
09/12/2022
Signed off — Alteration
FILING FOR REAR CONCRETE STEP TO CELLAR
Q00708030-I1
05/19/2022
Permit issued — General Construction
Q00708030-I1-GC
04/02/2022
Filed — Alteration
FILING FOR REAR CONCRETE STEP TO CELLAR
Q00708030-I1
04/02/2022
Special inspection requirement — Concrete - Cast-In-Place
Akeeb Shekoni
04/02/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
04/02/2022
Special inspection requirement — Energy Code Compliance Inspections
Akeeb Shekoni
04/02/2022
Special inspection requirement — Fire-Resistance Rated Construction
Akeeb Shekoni
03/28/2022
Special inspection requirement — Final
HANSA PERSAUD
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offCA CONSTRUCTION05/19/2022
BISOTISSUEDKAMTECH RESTORATION CORP04/08/2021
1 project · most recent 04/07/2021
FiledStatusContractorScope
04/07/2021CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/02/2022Concrete - Cast-In-PlaceAkeeb Shekonispecial
04/02/2022Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
04/02/2022Energy Code Compliance InspectionsAkeeb Shekoniprogress
04/02/2022Fire-Resistance Rated ConstructionAkeeb Shekoniprogress
03/28/2022FinalHANSA PERSAUDprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/26/2026Q00708030-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
04/02/2021440671042Open ↗
▸BISWORK PERMIT APPLICATION1
04/08/2021440671042Open ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
08/22/2026Q00708030-I1Open ↗
08/22/2026Q00708030-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
04/02/2021440671042Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/26/2026Q00708030-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026Q00708030-I1Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
04/08/2021440671042Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/02/2021440671042Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/26/2026Q00708030-I1Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
06/11/2021440671042Open ↗
04/07/2021440671042Open ↗
04/02/2021440671042Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
04/02/2021440671042Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
06/11/2021440671042Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/11/2021440671042Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
06/11/2021440671042Open ↗
04/07/2021440671042Open ↗
04/02/2021440671042Open ↗
▸Approvals, Objections & Sign-offs2
▸BISFINAL ELECTRICAL SIGNOFF1
06/11/2021440671042Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/11/2021440671042Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
06/11/2021440671042Open ↗
04/02/2021440671042Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
04/02/2021440671042Open ↗
▸Other Documents1
▸BISTax Abatement Miscellaneous1
06/11/2021440671042Open ↗