← Back
One family attached or semi-detached
1837 EAST 38 STREET
BROOKLYN · Marine Park-Mill Basin-Bergen Beach · BIN 3239290
💬 Discuss this project
1930Year Built
2Stories
A5Building Class
R3-2Zoning
1,440 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 2,400 sf lot · 0.6 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbing
Cellar7p · 2 filings · 15 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M JUST ARCHITECTURE PC310/26/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JUST ARCHITECTURE603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BIG APPLE SEWER & DRAIN IPlumbing607/08/2026
NEGLIACCIO.IMPROVEMENTSGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HANSEN ENGINEERING PC8174110/11/2021
Building Lifecycle
All (27)Filed (3)Permit Issued (2)Signed Off (2)Violation (6)Inspection (4)Objection (4)Special Inspection (6)
06/28/2022
Signed off — Alteration
B00601086-I1
06/28/2022
Signed off — Alteration
Legalize (1) shower, (1) toilet, & (1) sink at cellar. Cap & Remove (1) gas range at cellar. This application is being filed to correct the following ECB Violations: 35535284J, 39043593H, & 39043592X
B00608965-I1
06/14/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/14/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/13/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/13/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/27/2022
Permit issued — General Construction
B00601086-I1-GC
12/07/2021
Permit issued — Plumbing
B00608965-I1-PL
10/27/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ryan Hansen
10/27/2021
Special inspection requirement — Energy Code Compliance Inspections
Ryan Hansen
10/27/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Ryan Hansen
10/26/2021
Filed — Alteration
Legalize (1) shower, (1) toilet, & (1) sink at cellar. Cap & Remove (1) gas range at cellar. This application is being filed to correct the following ECB Violations: 35535284J, 39043593H, & 39043592X
B00608965-P1
10/26/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/26/2021
Special inspection requirement — Energy Code Compliance Inspections
10/26/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
10/13/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/13/2021
Objection raised — Other
10/13/2021
Objection resolved — Addressed
10/13/2021
Objection raised — Scope
10/13/2021
Objection resolved — Addressed
10/11/2021
Filed — Alteration
B00601086-I1
10/11/2021
Filed — Alteration
Legalize (1) shower, (1) toilet, & (1) sink at cellar. Cap & Remove (1) gas range at cellar. This application is being filed to correct the following ECB Violations: 35535284J, 39043593H, & 39043592X
B00608965-I1
09/29/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/17/2021
Violation issued (ECB, closed)
Construction
06/28/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/2021
Violation issued (ECB, closed)
Construction
06/28/2021
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNEGLIACCIO.IMPROVEMENTS04/27/2022
DOB NOWPlumbingSigned-offBIG APPLE SEWER & DRAIN I12/07/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/14/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/14/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/13/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/13/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
10/27/2021Fire-Resistant Penetrations and JointsRyan Hansenspecial
10/27/2021Energy Code Compliance InspectionsRyan Hansenprogress
10/27/2021HVAC-R and service water piping design and insulationRyan Hansenenergy_progress
10/26/2021Fire-Resistant Penetrations and Joints—special
10/26/2021Energy Code Compliance Inspections—progress
10/26/2021HVAC-R and service water piping design and insulation—energy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/01/2026B00601086-I1Request digital key ↗
09/01/2026B00608965-P1Request digital key ↗
08/14/2026B00608965-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWRestrictive Declaration1
08/14/2026B00608965-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/01/2026B00601086-I1Open ↗
09/01/2026B00608965-I1Open ↗
09/01/2026B00608965-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026B00608965-I1Open ↗
08/24/2026B00608965-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026B00608965-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/01/2026B00601086-I1Open ↗
09/01/2026B00608965-P1Open ↗
08/14/2026B00608965-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/14/2026B00608965-I1Open ↗
08/13/2026B00601086-I1Open ↗