← Back
BuildNYC
Large suburban residence
184-38 MIDLAND PARKWAY
QUEENS · BIN 4156070
💬 Discuss this project
1935Year Built
2.5Stories
A3Building Class
R1-2Zoning
3,431 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Large suburban residence · 6,600 sf lot · 0.52 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipment
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofNew two-story building construction with cellar and attic4p · 2 filings · 20 docs
AtticNew two-story building construction with cellar and attic13p · 2 filings · 20 docs
Floor 2Unit 2M, Unit PH013p · 3 filings · 20 docs
Floor 1New two-story building construction with cellar and attic13p · 3 filings · 20 docs
CellarNew two-story building construction with cellar and attic13p · 3 filings · 20 docs
Site & exteriorInstallation and removal of fences19p · 2 filings · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/23/2021$1.4M—Private party → Private party$402/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AA Building & Inspection Service610/24/2023
Alpha Engineering104/18/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Dmconsulting68601203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Remax ConstructionGeneral Contractor603/21/2026
Remax ConstructionScaffold407/08/2026
Gregg NY PlumbingPlumbing207/08/2026
RCM GroupGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP Concrete Testing and I6252610/24/2023
Building Lifecycle
12/18/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/15/2023
Signed off — Alteration
HEREWITH FILING ALTERATION IN CONJUNCTION WITH ALT # Q00626073-I1FOR PLUMBING WORK IN CELLAR, FIRST, AND SECOND AS PER PLANS FILED.
Q00724081-I1
11/08/2023
Permit expired, never signed off — Mechanical Systems
The city's record still shows this permit as issued, with no sign-off on its filing
Q00626073-I1-GC-CX
10/31/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
10/31/2023
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
75 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offGregg NY Plumbing10/10/2023
DOB NOWConstruction FenceSigned-offRemax Construction06/15/2023
DOB NOWMechanical SystemsPermit IssuedRCM Group11/30/2022
DOB NOWPlumbingSigned-offGregg NY Plumbing06/21/2022
DOB NOWFoundationSigned-offRemax Construction06/17/2022
DOB NOWGeneral ConstructionPermit IssuedRemax Construction06/03/2022
DOB NOWConstruction FenceSigned-offRemax Construction05/19/2022
1 project · most recent 01/23/2023
Heating Systems Ventilation Systems
FiledStatusContractorScope
01/23/2023Permit IssuedRCM GroupHeating Systems, Ventilation Systems
3 projects · most recent 01/09/2024
General Wiring
FiledStatusContractorScope
01/09/2024CompleteKings Electric—
10/25/2023CompleteKings ElectricGeneral Wiring
06/23/2022CompleteKings Electric—
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
12/18/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/16/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/03/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/03/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/03/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/03/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 90
DateRequirementInspectorRole
10/31/2023Maintenance informationYounes Abouyaalaenergy_progress
10/31/2023Energy Code Compliance InspectionsYounes Abouyaalaprogress
10/31/2023Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
10/24/2023Maintenance informationYounes Abouyaalaenergy_progress
10/24/2023Energy Code Compliance InspectionsYounes Abouyaalaprogress
10/24/2023Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
01/26/2023Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
01/26/2023Mechanical SystemsINDARDEO PARBHUNATHspecial
01/26/2023Energy Code Compliance InspectionsYounes Abouyaalaprogress
01/26/2023Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
01/26/2023FinalNAVEEN KUMARprogress
01/26/2023Insulation placement and R valuesYounes Abouyaalaenergy_progress
01/26/2023HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
01/26/2023Fenestration areasYounes Abouyaalaenergy_progress
01/26/2023Interior lighting powerYounes Abouyaalaenergy_progress
01/26/2023Maintenance informationYounes Abouyaalaenergy_progress
01/26/2023Shutoff dampersYounes Abouyaalaenergy_progress
01/26/2023Subsurface Investigations (Borings/Test Pits)FAHAD FATEHspecial
01/26/2023Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
01/26/2023Exterior lighting powerYounes Abouyaalaenergy_progress
01/26/2023FireplacesYounes Abouyaalaenergy_progress
01/26/2023Protection of exposed foundation insulationYounes Abouyaalaenergy_progress
01/26/2023Duct leakage testing, insulation and designYounes Abouyaalaenergy_progress
01/26/2023Permanent certificateYounes Abouyaalaenergy_progress
01/26/2023Air barrier - visual inspectionYounes Abouyaalaenergy_progress
Latest 25 of 90.
74 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account