← Back
Miscellaneous warehouse
Brinks Building
184-45 147 AVENUE · BIN 4286095
💬 Discuss this project
1989Year Built
1Stories
E9Building Class
R3-2Zoning
29,393 sfGross Floor Area
1Units
LL97 Covered0 Open ViolationsFDNY Report ↗
Miscellaneous warehouse · Owner of record: WF INDUSTRIAL III LLC · 52,553 sf lot · 0.56 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralMechanicalPlumbingCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction10p · 2 filings · 16 docs
Floor 1Under Construction23p · 5 filings · 20 docs
MezzanineUnder Construction25p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WILDFLOWER LTD707/08/2026
BRINKS2207/08/2026
WF INDUSTRIAL III LLC103/22/2026
REDFERN ASSOC203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/30/2019$5.5M—Private party → WF INDUSTRIAL III LLC$187/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GILSANZ MURRAY STEFICEK LLP303/06/2026
TULLER/MCNEALUS/FELD410/23/2023
JACK GREEN ASSOCIATES310/23/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL BUILDING CONSULTANTS703/21/2026
SOL BUILDING CONSULTING SERVICES303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J.V.S. SPRINT ENTERPRISESGeneral Contractor907/08/2026
KULKA, LLCGeneral Contractor107/08/2026
PARK EAST CONSTRUCTIONGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
C.M. TESTING LABORATORY,1352203/06/2026
GILSANZ MURRAY STEFICEK240212/15/2023
JACK GREEN ASSOCIATES422410/23/2023
Building Lifecycle
All (54)Filed (10)Permit Issued (7)Signed Off (1)Violation (4)Inspection (7)Special Inspection (25)
03/23/2026
Permit issued — Foundation
Q01361997-I1-FO
03/20/2026
Permit issued — Structural
Q01361997-S1-ST
03/06/2026
Filed — Alteration
FOUNDATION WORK FOR SLAB ON GRADE REPLACEMENT AND NEW PILES AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01361997-I1
03/06/2026
Filed — Alteration
FOUNDATION WORK FOR SLAB ON GRADE REPLACEMENT AND NEW PILES AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01361997-S1
02/25/2026
Special inspection requirement — Concrete - Cast-In-Place
JOHN SEMIOLI
02/25/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOHN SEMIOLI
02/25/2026
Special inspection requirement — Subgrade Inspections
JOHN SEMIOLI
02/25/2026
Special inspection requirement — Post-installed Anchors
JOHN SEMIOLI
02/19/2026
Special inspection requirement — Final
JOHN SEMIOLI
08/15/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/04/2024
Permit issued — Structural
Q00954371-I1-ST
11/15/2024
Permit issued — Mechanical Systems
Q00948747-I1-MS
11/07/2024
Permit issued — General Construction
Q00948738-I1-GC
10/10/2024
Violation issued (FDNY_ORDER, closed)
12/15/2023
Filed — Alteration
STRUCTURAL FRAMING FOR GROUND FLOOR AND NEW OPENING FOR NEW DOOR AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q00954371-I1
10/27/2023
Special inspection requirement — Masonry
Philip Murray
10/27/2023
Special inspection requirement — Structural Steel - Details
Philip Murray
10/27/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Philip Murray
10/27/2023
Special inspection requirement — Post-installed Anchors
Philip Murray
10/27/2023
Special inspection requirement — Sprayed fire-resistant materials
Philip Murray
10/27/2023
Special inspection requirement — Structural Steel - High Strength Bolting
Philip Murray
10/27/2023
Special inspection requirement — Structural Steel - Welding
Philip Murray
10/27/2023
Special inspection requirement — Final
Philip Murray
10/23/2023
Filed — Alteration
Q00948747-I1
10/23/2023
Filed — Alteration
SPRINKLER SYSTEM MODIFICATION FOR JFK FACILITY AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q00948772-I1
10/23/2023
Filed — Alteration
PLUMBING MODIFICATIONS FOR JFK FACILITY AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q00948763-I1
10/23/2023
Filed — Alteration
INTERIOR AND EXTERIOR RENOVATIONS FOR JFK FACILITY AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q00948738-I1
10/16/2023
Special inspection requirement — Sprinkler Systems
JACK GREEN
10/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACK GREEN
10/16/2023
Special inspection requirement — Energy Code Compliance Inspections
JACK GREEN
10/16/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
JACK GREEN
10/16/2023
Special inspection requirement — HVAC-R and service water heating equipment
JACK GREEN
10/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACK GREEN
10/16/2023
Special inspection requirement — Masonry
Philip Murray
10/16/2023
Special inspection requirement — Energy Code Compliance Inspections
JACK GREEN
10/16/2023
Special inspection requirement — Final
andrew tuller
10/16/2023
Special inspection requirement — Interior lighting power
JACK GREEN
10/16/2023
Special inspection requirement — Lighting controls
JACK GREEN
05/17/2023
Signed off — Alteration CO
Revised plans for the original scope of work referenced on Q00672630-I1
Q00672630-S1
04/28/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/16/2023
Filed — Alteration CO
Revised plans for the original scope of work referenced on Q00672630-I1
Q00672630-P1
02/16/2023
Special inspection requirement — Final
02/10/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/07/2023
Permit issued — General Construction
Q00672630-S1-GC
01/20/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/23/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/13/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/12/2022
Filed — Alteration CO
Revised plans for the original scope of work referenced on Q00672630-I1
Q00672630-S1
12/01/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/19/2022
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
03/31/2022
Permit issued — General Construction
Q00672630-I1-GC
02/17/2022
Filed — Alteration CO
Revised plans for the original scope of work referenced on Q00672630-I1
Q00672630-I1
12/01/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedJ.V.S. SPRINT ENTERPRISES03/23/2026
DOB NOWStructuralPermit IssuedJ.V.S. SPRINT ENTERPRISES03/20/2026
DOB NOWStructuralPermit IssuedJ.V.S. SPRINT ENTERPRISES12/04/2024
DOB NOWMechanical SystemsPermit IssuedJ.V.S. SPRINT ENTERPRISES11/15/2024
DOB NOWGeneral ConstructionPermit IssuedJ.V.S. SPRINT ENTERPRISES11/07/2024
DOB NOWGeneral ConstructionSigned-offPARK EAST CONSTRUCTION02/07/2023
DOB NOWGeneral ConstructionPermit IssuedKULKA, LLC03/31/2022
BISOTISSUEDUGE USA INC06/25/2020
BISPLISSUEDSIGNORE & SONS PLBG CORP01/17/2018
BISSPISSUEDPAT SEMENTA P&H CO INC08/23/2017
BISSPISSUEDPAT SEMENTA P&H CO INC07/24/2017
BISOTISSUEDJ.V.S. SPRINT ENTERPRISES01/04/2017
BISMHISSUEDJ.V.S. SPRINT ENTERPRISES01/04/2017
BISMHISSUEDALAMA SERVICE INC08/18/2016
BISPLISSUEDSIGNORE & SONS PLBG CORP03/16/2016
BISMHISSUEDJ.V.S. SPRINT ENTERPRISES03/02/2016
BISOTISSUEDJ.V.S. SPRINT ENTERPRISES03/02/2016
BISEQISSUEDJ.V.S. SPRINT ENTERPRISES03/02/2016
BISEQISSUEDJOHN P. PICONE INC04/03/1996
BIS—ISSUEDJOHN P. PICONE INC04/03/1996
1 project · most recent 10/23/2023
FiledStatusContractorScope
10/23/2023——201 heads
1 project · most recent 10/23/2023
Water/Sanitary
FiledStatusContractorScope
10/23/2023——Water/Sanitary
1 project · most recent 11/19/2020
FiledStatusContractorScope
11/19/2020CompleteSUPREME ELECTRIC CORP2 meters, 1 new_meters
2 projects · most recent 03/06/2026
Concrete Steel Masonry
FiledStatusContractorScope
03/06/2026Permit IssuedJ.V.S. SPRINT ENTERPRISESConcrete
12/15/2023Permit IssuedJ.V.S. SPRINT ENTERPRISESSteel, Masonry
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/15/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/28/2023Pass-Final CND-Occupancy InspectionPassView ↗
02/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/20/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/23/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/13/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/19/2022Fail-Final CND-Occupancy InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
02/25/2026Concrete - Cast-In-PlaceJOHN SEMIOLIspecial
02/25/2026Structural Stability – Alterations of existing buildingsJOHN SEMIOLIspecial
02/25/2026Subgrade InspectionsJOHN SEMIOLIspecial
02/25/2026Post-installed AnchorsJOHN SEMIOLIspecial
02/19/2026FinalJOHN SEMIOLIprogress
10/27/2023MasonryPhilip Murrayspecial
10/27/2023Structural Steel - DetailsPhilip Murrayspecial
10/27/2023Structural Stability – Alterations of existing buildingsPhilip Murrayspecial
10/27/2023Post-installed AnchorsPhilip Murrayspecial
10/27/2023Sprayed fire-resistant materialsPhilip Murrayspecial
10/27/2023Structural Steel - High Strength BoltingPhilip Murrayspecial
10/27/2023Structural Steel - WeldingPhilip Murrayspecial
10/27/2023FinalPhilip Murrayprogress
10/16/2023Sprinkler SystemsJACK GREENspecial
10/16/2023Fire-Resistant Penetrations and JointsJACK GREENspecial
10/16/2023Energy Code Compliance InspectionsJACK GREENprogress
10/16/2023HVAC-R and service water piping design and insulationJACK GREENenergy_progress
10/16/2023HVAC-R and service water heating equipmentJACK GREENenergy_progress
10/16/2023Fire-Resistant Penetrations and JointsJACK GREENspecial
10/16/2023MasonryPhilip Murrayspecial
10/16/2023Energy Code Compliance InspectionsJACK GREENprogress
10/16/2023Finalandrew tullerprogress
10/16/2023Interior lighting powerJACK GREENenergy_progress
10/16/2023Lighting controlsJACK GREENenergy_progress
02/16/2023Final—progress
▾Documents — 240 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/25/2026Q00672630-S1Request digital key ↗
08/25/2026Q00672630-P1Request digital key ↗
08/25/2026Q00672630-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits34
▸BISPLAN / WORK APPROVAL APPLICATION22
09/09/2022421353822Open ↗
09/09/2022421255126Open ↗
12/10/2019440577314Open ↗
Showing 3 of 22 on file for this type
▸BISWORK PERMIT APPLICATION11
06/25/2020440577314Open ↗
01/22/2018421353831Open ↗
08/24/2017421353822Open ↗
Showing 3 of 11 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
08/03/2018421255135Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00672630-I1Open ↗
▸Seals & Professional Certifications61
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION25
07/16/2018421255135Open ↗
06/19/2018421255135Open ↗
06/19/2018421353831Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/01/2026Q00954371-I1Open ↗
09/01/2026Q00954371-I1Open ↗
09/01/2026Q00954371-I1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/23/2026Q00948763-I1Open ↗
08/23/2026Q00948747-I1Open ↗
08/23/2026Q00948772-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026Q00954371-I1Open ↗
08/29/2026Q00948763-I1Open ↗
08/29/2026Q00948763-I1Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
12/10/2019440577314Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/01/2016421245129Open ↗
▸BISProfessional and Owner Certification (POC3)1
07/01/2016421245129Open ↗
▸Trade Schedules & Equipment22
▸BISEQUIPMENT USE PERMITS8
01/10/2019421353831Open ↗
08/06/2018421255135Open ↗
08/06/2018421255135Open ↗
Showing 3 of 8 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT7
01/08/2019421353831Open ↗
12/14/2018421353831Open ↗
08/03/2018421255135Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
08/02/2016421353822Open ↗
08/02/2016421353831Open ↗
01/22/2016421255126Open ↗
Showing 3 of 6 on file for this type
▸BISSPRINKLER/STANDPIPE ELECTRICAL LETTER1
07/20/2022421255126Open ↗
▸Safety & Tenant Protection5
▸BISTenant Protection Plan and Notes3
08/02/2016421353831Open ↗
08/02/2016421353822Open ↗
12/10/2019440577314Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00672630-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00672630-I1Open ↗
▸Environmental & Asbestos14
▸BISASBESTOS: CERTIFICATION (DEP ACP5)7
01/23/2020440577314Open ↗
08/02/2016421353831Open ↗
08/02/2016421353822Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/23/2026Q00948763-I1Open ↗
08/23/2026Q00948747-I1Open ↗
08/23/2026Q00948772-I1Open ↗
Showing 3 of 7 on file for this type
▸Energy Compliance20
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS12
07/16/2018421255135Open ↗
06/19/2018421353831Open ↗
06/19/2018421255135Open ↗
Showing 3 of 12 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS5
12/16/2020440577314Open ↗
07/16/2018421255135Open ↗
06/19/2018421353831Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/16/2020440577314Open ↗
12/10/2019440577314Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
12/16/2020440577314Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/16/2020440577314Open ↗
12/10/2019440577314Open ↗
▸BISHYDRO FLOW TEST LETTER2
08/02/2016421353822Open ↗
06/20/2016421255126Open ↗
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
01/08/2019421353831Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01361997-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01361997-I1Open ↗
▸Approvals, Objections & Sign-offs14
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
07/21/2022421255126Open ↗
07/21/2022421353822Open ↗
01/08/2019421353831Open ↗
Showing 3 of 9 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
12/16/2020440577314Open ↗
01/23/2020440577314Open ↗
08/24/2017421353822Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
01/22/2016421255135Open ↗
09/09/2015421210674Open ↗
▸Cost, Insurance & Ownership19
▸BISCOST AFFIDAVIT17
12/16/2020440577314Open ↗
06/19/2018421353831Open ↗
06/19/2018421353831Open ↗
Showing 3 of 17 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
07/06/2022421353822Open ↗
07/06/2022421255126Open ↗
▸Filing & Intake Forms31
▸BISADDITIONAL INFORMATION12
10/14/2020440577314Open ↗
01/23/2020440577314Open ↗
11/10/2018421353831Open ↗
Showing 3 of 12 on file for this type
▸BISEFILING COVER SHEET10
08/02/2016421353822Open ↗
08/02/2016421353831Open ↗
08/02/2016421353831Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM8
09/11/2018421353831Open ↗
08/03/2018421255135Open ↗
07/16/2018421255135Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
12/10/2019440577314Open ↗
▸Other Documents2
▸BISSP/SD DEVICE CERT : LTR-LIC ELECT1
07/20/2022421255126Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q00672630-I1Open ↗