← Back
Two family brick
1842 TOMLINSON AVENUE
BRONX · Morris Park · BIN 2045710
💬 Discuss this project
1940Year Built
1Stories
B1Building Class
R4Zoning
1,446 sfGross Floor Area
2Units
Two family brick · 2,200 sf lot · 0.66 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21 filing · 12 docs
Floor 1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/16/2021$635K—Private party → Private party$439/sf building
07/30/2014$410K—TOMLINSON REALTY, LLC → Private party$284/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KUSHNER STUDIOS204/13/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KUSHNER STUDIOS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LIO LIBRA CONTRACTING INCGeneral Contractor107/08/2026
A P PLUMBING&HEATING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CROSSCHECK INSPECTION SER544204/13/2021
Building Lifecycle
All (10)Filed (2)Permit Issued (2)Special Inspection (6)
06/29/2021
Permit issued — Plumbing
X00499188-S1-PL
05/28/2021
Permit issued — General Construction
X00499188-I1-GC
04/13/2021
Filed — Alteration
MINOR RENOVATION OF AN EXISTING RESIDENTIAL KITCHEN INCLUDING THE REMOVAL OF NON-LOAD BEARING WALLS AND THE INSTALLATION OF NEW CABINETS AND COUNTERTOPS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00499188-S1
04/13/2021
Filed — Alteration
MINOR RENOVATION OF AN EXISTING RESIDENTIAL KITCHEN INCLUDING THE REMOVAL OF NON-LOAD BEARING WALLS AND THE INSTALLATION OF NEW CABINETS AND COUNTERTOPS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00499188-I1
04/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
04/13/2021
Special inspection requirement — Energy Code Compliance Inspections
EUGENE BIFULCO
04/13/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
EUGENE BIFULCO
04/06/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
04/06/2021
Special inspection requirement — Final
EUGENE BIFULCO
04/06/2021
Special inspection requirement — Lighting in dwelling units
EUGENE BIFULCO
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedA P PLUMBING&HEATING INC06/29/2021
DOB NOWGeneral ConstructionSigned-offLIO LIBRA CONTRACTING INC05/28/2021
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
04/13/2021Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
04/13/2021Energy Code Compliance InspectionsEUGENE BIFULCOprogress
04/13/2021HVAC-R and service water piping design and insulationEUGENE BIFULCOenergy_progress
04/06/2021Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
04/06/2021FinalEUGENE BIFULCOprogress
04/06/2021Lighting in dwelling unitsEUGENE BIFULCOenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026X00499188-S1Request digital key ↗
08/25/2026X00499188-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
08/26/2026X00499188-I1Open ↗
08/26/2026X00499188-I1Open ↗
08/24/2026X00499188-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026X00499188-S1Open ↗
08/25/2026X00499188-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026X00499188-I1Open ↗
08/24/2026X00499188-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026X00499188-S1Open ↗
08/25/2026X00499188-I1Open ↗