← Back
Primarily 3 family with 1 store or office
1843 EASTERN PARKWAY
BROOKLYN · BIN 3038625
💬 Discuss this project
1898Year Built
3Stories
S3Building Class
R6Zoning
3,882 sfGross Floor Area
4Units
Rent Stabilized76 Open Violations 74 unresolved · 2 paperwork only ▸FDNY Report ↗
Primarily 3 family with 1 store or office · 1,760 sf lot · 2.21 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionOther
Permit Issued — active, not yet Signed-off
RoofUnder Construction31p · 2 filings · 20 docs
Floor 3Under Construction32p · 2 filings · 20 docs
Floor 2Under Construction30p · 2 filings · 20 docs
Floor 1Under Construction43p · 3 filings · 20 docs
CellarUnder Construction49p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KURT2309/15/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/03/2021$1.4M—— → —$361/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
.1109/09/2026
ANDREW FREDMAN ARCHITECT LLC604/09/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONVERSANO ASSOCIATES, INC.2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CONSTRUCTION XPERT INCGeneral Contractor707/08/2026
VILLAGE P & H NY INCPlumbing207/08/2026
VILLAGE P & H NY INCFire Protection106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP CONCRETE TESTING AND I62521209/09/2026
Building Lifecycle
All (197)Filed (17)Permit Issued (8)Violation (60)Inspection (5)Objection (77)Special Inspection (30)
09/09/2026
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH.
B00795719-P4
08/14/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/13/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/28/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
INDARDEO PARBHUNATH
07/28/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
INDARDEO PARBHUNATH
07/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
INDARDEO PARBHUNATH
07/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
INDARDEO PARBHUNATH
07/28/2026
Special inspection requirement — Energy Code Compliance Inspections
INDARDEO PARBHUNATH
07/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
07/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/06/2026
Permit issued — Plumbing
B00795719-I1-PL
06/09/2026
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH.
B00795719-P3
05/26/2026
Special inspection requirement — Heating Systems
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — Mechanical Systems
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — Final
NAVEEN KUMAR
05/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — Duct leakage testing, insulation and design
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — Energy Code Compliance Inspections
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — Shutoff dampers
INDARDEO PARBHUNATH
05/26/2026
Special inspection requirement — Maintenance information
INDARDEO PARBHUNATH
05/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
05/07/2026
Special inspection requirement — Sprinkler Systems
INDARDEO PARBHUNATH
04/28/2026
Special inspection requirement — Concrete - Cast-In-Place
INDARDEO PARBHUNATH
04/28/2026
Special inspection requirement — Post-installed Anchors
INDARDEO PARBHUNATH
04/28/2026
Special inspection requirement — Structural Steel - High Strength Bolting
INDARDEO PARBHUNATH
04/28/2026
Special inspection requirement — Structural Steel - Details
INDARDEO PARBHUNATH
04/28/2026
Special inspection requirement — Final
NAVEEN KUMAR
04/28/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
INDARDEO PARBHUNATH
04/28/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
INDARDEO PARBHUNATH
04/28/2026
Special inspection requirement — Structural Cold-Formed Steel
INDARDEO PARBHUNATH
04/17/2026
Permit issued — Mechanical Systems
B00776580-S2-MS
04/09/2026
Filed — Alteration
SPRINKLER SYSTEMS AS PER PLANS, FILED IN CONJUNCTION WITH ALT1 B00776580-I1.
B00795763-P2
04/09/2026
Filed — Alteration CO
MECHANICAL WORK AS PER PLANS FILED HEREWITH.
B00776580-P6
04/09/2026
Objection resolved — Resolved
04/09/2026
Objection resolved — Resolved
04/09/2026
Objection resolved — Resolved
04/08/2026
Objection raised — Admin
04/01/2026
Objection raised — Plumbing
04/01/2026
Objection raised — Plumbing
04/01/2026
Objection raised — Scope
03/21/2026
Filed — Alteration
PLUMBING WORK AS PER PLANS FILED HEREWITH.
B00795719-P2
03/21/2026
Filed — Alteration CO
MECHANICAL WORK AS PER PLANS FILED HEREWITH.
B00776580-P5
03/19/2026
Filed — Alteration CO
MECHANICAL WORK AS PER PLANS FILED HEREWITH.
B00776580-P4
03/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
03/10/2026
Special inspection requirement — Sprinkler Systems
INDARDEO PARBHUNATH
02/17/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
INDARDEO PARBHUNATH
09/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/05/2025
Permit issued — Plumbing
B00795719-I1-PL
05/02/2025
Permit issued — Sprinklers
B00795763-I1-EW-SP
04/24/2025
Permit issued — Structural
B00776580-S1-ST
04/18/2025
Permit issued — General Construction
B00776580-I1-GC
11/21/2024
Permit issued — Mechanical Systems
B00776580-S2-MS
10/30/2024
Permit issued — General Construction
B00776580-I1-GC
09/05/2024
Objection resolved — Addressed
09/05/2024
Objection resolved — Addressed
08/27/2024
Objection raised — Other
Latest 60 of 197 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedVILLAGE P & H NY INC07/06/2026
DOB NOWMechanical SystemsPermit IssuedCONSTRUCTION XPERT INC04/17/2026
DOB NOWPlumbingPermit IssuedVILLAGE P & H NY INC05/05/2025
DOB NOWSprinklersPermit IssuedVILLAGE P & H NY INC05/02/2025
DOB NOWStructuralPermit IssuedCONSTRUCTION XPERT INC04/24/2025
DOB NOWGeneral ConstructionPermit IssuedCONSTRUCTION XPERT INC04/18/2025
DOB NOWMechanical SystemsPermit IssuedCONSTRUCTION XPERT INC11/21/2024
DOB NOWGeneral ConstructionPermit IssuedCONSTRUCTION XPERT INC10/30/2024
BISOTISSUEDJ & M BLDG & REMOLDING INC08/22/1997
1 job · most recent 04/09/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/09/2026Permit IssuedCONSTRUCTION XPERT INCHeating and Air Conditioning Systems
Heat / Cool
York ARUM036GSS5 36,000 BTU · Vrf Outdoor ×2
ARUM048GSS5 48,000 BTU · Vrf Outdoor ×2
Daikin 4MXLH36WVJU9 34,400 BTU · Condensing Unit ×2
1 job · most recent 04/09/2026
FiledStatusContractorScope
04/09/2026Permit IssuedPARAMOUNT SERVICES, LLC126 heads
1 job · most recent 09/09/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/09/2026Permit IssuedPARAMOUNT SERVICES, LLCGas, Storm, Water/Sanitary
1 job · most recent 11/21/2025
General Wiring
FiledStatusContractorScope
11/21/2025Permit IssuedBLU ELECTRICAL SVS INCGeneral Wiring
1 job · most recent 04/09/2026
Steel Concrete
FiledStatusContractorScope
04/09/2026Permit IssuedCONSTRUCTION XPERT INCSteel, Concrete
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/14/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/13/2026Pass-Final CND-Occupancy InspectionPassView ↗
07/17/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/10/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 83
DateRequirementInspectorRole
07/28/2026HVAC-R and service water piping design and insulationINDARDEO PARBHUNATHenergy_progress
07/28/2026HVAC-R and service water heating equipmentINDARDEO PARBHUNATHenergy_progress
07/28/2026HVAC-R and service water heating system controlsINDARDEO PARBHUNATHenergy_progress
07/28/2026Energy Code Compliance InspectionsINDARDEO PARBHUNATHprogress
07/28/2026Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
07/28/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationINDARDEO PARBHUNATHspecial
05/26/2026Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
05/26/2026Heating SystemsINDARDEO PARBHUNATHspecial
05/26/2026Shutoff dampersINDARDEO PARBHUNATHenergy_progress
05/26/2026HVAC-R and service water piping design and insulationINDARDEO PARBHUNATHenergy_progress
05/26/2026Duct leakage testing, insulation and designINDARDEO PARBHUNATHenergy_progress
05/26/2026Maintenance informationINDARDEO PARBHUNATHenergy_progress
05/26/2026Energy Code Compliance InspectionsINDARDEO PARBHUNATHprogress
05/26/2026FinalNAVEEN KUMARprogress
05/26/2026Mechanical SystemsINDARDEO PARBHUNATHspecial
05/26/2026HVAC-R and service water heating equipmentINDARDEO PARBHUNATHenergy_progress
05/26/2026HVAC-R and service water heating system controlsINDARDEO PARBHUNATHenergy_progress
05/07/2026Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
05/07/2026Sprinkler SystemsINDARDEO PARBHUNATHspecial
04/28/2026Concrete - Cast-In-PlaceINDARDEO PARBHUNATHspecial
04/28/2026Post-installed AnchorsINDARDEO PARBHUNATHspecial
04/28/2026Structural Steel - High Strength BoltingINDARDEO PARBHUNATHspecial
04/28/2026Structural Steel - DetailsINDARDEO PARBHUNATHspecial
04/28/2026Structural Stability – Alterations of existing buildingsINDARDEO PARBHUNATHspecial
04/28/2026FinalNAVEEN KUMARprogress
Latest 25 of 83.
▾Documents — 131 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
08/24/2026B00795763-P1Request digital key ↗
08/24/2026B00795763-P2Request digital key ↗
08/17/2026B00795719-P4Request digital key ↗
Showing 3 of 17 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B00776580-P1Open ↗
08/13/2026B00776580-P4Open ↗
08/13/2026B00776580-I1Open ↗
▸Seals & Professional Certifications75
▸DOB NOWProgress Inspector Seal & Signature30
09/23/2026B00795719-P4Open ↗
09/23/2026B00795719-P4Open ↗
09/23/2026B00795719-P4Open ↗
Showing 3 of 30 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature28
09/23/2026B00795719-P4Open ↗
09/23/2026B00795719-P4Open ↗
08/29/2026B00776580-P6Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/24/2026B00795763-I1Open ↗
08/24/2026B00795763-P1Open ↗
08/17/2026B00795719-P3Open ↗
Showing 3 of 17 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026B00776580-P1Open ↗
08/13/2026B00776580-P4Open ↗
08/13/2026B00776580-I1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026B00776580-P1Open ↗
08/13/2026B00776580-P4Open ↗
08/13/2026B00776580-I1Open ↗
▸Environmental & Asbestos17
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
08/24/2026B00795763-P1Open ↗
08/17/2026B00795719-P3Open ↗
08/17/2026B00795719-P4Open ↗
Showing 3 of 17 on file for this type
▸Other Documents13
▸DOB NOWProperty Ownership Certification3
08/17/2026B00776580-P4Open ↗
08/17/2026B00776580-P1Open ↗
08/15/2026B00776580-I1Open ↗
▸DOB NOWSite Survey: Initial3
08/13/2026B00776580-I1Open ↗
08/13/2026B00776580-P1Open ↗
08/13/2026B00776580-P4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026B00776580-P4Open ↗
08/13/2026B00776580-P1Open ↗
08/13/2026B00776580-I1Open ↗
▸DOB NOWPlot Diagram3
08/13/2026B00776580-I1Open ↗
08/13/2026B00776580-P1Open ↗
08/13/2026B00776580-P4Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00776580-I1Open ↗