← Back
Miscellaneous two family
1847 HARRISON AVENUE
BRONX · BIN 2008546
💬 Discuss this project
1910Year Built
3Stories
B9Building Class
R7-1Zoning
1,840 sfGross Floor Area
2Units
1 Open Violation ▸
Miscellaneous two family · 2,382 sf lot · 0.77 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 3Under Construction21p · 1 filing · 20 docs
Floor 2Under Construction22p · 1 filing · 20 docs
Floor 1Under Construction21p · 2 filings · 20 docs
BasementUnder Construction23p · 1 filing · 20 docs
1 job · most recent 08/24/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/24/2026Permit IssuedBABA CONSTRUCTION CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin RXS12LVJU 60,000 BTU · Heat Pump Outdoor ×5
2MXS18NMVJUA 54,000 BTU · Heat Pump Outdoor ×3
Ventilation
Nutone QTXEN150 150 CFM · Kitchen Exhaust ×11
AEN110 110 CFM · Exhaust Fan ×8
1 job · most recent 08/24/2026
Sprinkler System
FiledStatusContractorScope
08/24/2026Permit IssuedDOUG'S PLBG & HTG SERV COSprinkler System
1 job · most recent 08/24/2026
Water/Sanitary
FiledStatusContractorScope
08/24/2026Permit IssuedDOUG'S PLBG & HTG SERV COWater/Sanitary
1 job · most recent 06/16/2026
General Wiring
FiledStatusContractorScope
06/16/2026Permit IssuedK.N.C ELECTRIC INCGeneral Wiring
1 job · most recent 08/24/2026
FiledStatusContractorScope
08/24/2026Permit IssuedBABA CONSTRUCTION CORP1 scope_items
1 job · most recent 01/23/2026
Fence
FiledStatusContractorScope
01/23/2026Permit IssuedBABA CONSTRUCTION CORPFence
Building Lifecycle
All (36)Filed (8)Permit Issued (7)Signed Off (1)Violation (13)Inspection (7)
08/24/2026
Filed — Alteration CO
Filing Sprinkler application subsequent to primary approved Job #X01012800-I1
X01012800-P2
08/20/2026
Permit issued — Structural
X01012800-S4-ST
08/06/2026
Signed off — Alteration
Installation of temporary construction fence at proposed 8 family dwelling.
X01350698-I1
08/04/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/04/2026
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
07/28/2026
Permit issued — Mechanical Systems
X01012800-S1-MS
07/14/2026
Filed — Alteration CO
Filing Sprinkler application subsequent to primary approved Job #X01012800-I1
X01012800-S4
07/14/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/14/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/14/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/13/2026
Permit issued — Sprinklers
X01012800-S3-EW-SP
02/12/2026
Permit issued — General Construction
X01012800-I1-GC
01/27/2026
Permit issued — Construction Fence
X01350698-I1-FN
01/23/2026
Filed — Alteration
Installation of temporary construction fence at proposed 8 family dwelling.
X01350698-I1
11/19/2025
Permit issued — Plumbing
X01012800-S2-PL
11/12/2025
Permit issued — General Construction
X01012800-I1-GC
04/22/2025
Filed — Alteration CO
Filing Sprinkler application subsequent to primary approved Job #X01012800-I1
X01012800-P1
02/19/2025
Filed — Alteration CO
Filing Sprinkler application subsequent to primary approved Job #X01012800-I1
X01012800-S3
06/21/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
05/06/2024
Filed — Alteration CO
Filing Sprinkler application subsequent to primary approved Job #X01012800-I1
X01012800-S1
05/03/2024
Filed — Alteration CO
Filing Sprinkler application subsequent to primary approved Job #X01012800-I1
X01012800-S2
02/29/2024
Filed — Alteration CO
Filing Sprinkler application subsequent to primary approved Job #X01012800-I1
X01012800-I1
09/02/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/08/2018
Violation issued (HPD, open)
C
04/04/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/04/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/04/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/04/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/12/2012
Violation issued (ECB, closed)
Unknown
01/12/2012
Violation issued (ECB, closed)
Unknown
01/12/2012
Violation issued (ECB, closed)
Unknown
01/12/2012
Violation issued (ECB, closed)
Construction
01/07/2012
Violation issued (ECB, closed)
Construction
01/07/2012
Violation issued (ECB, closed)
Construction
08/01/2011
Violation issued (ECB, closed)
Construction
08/01/2011
Violation issued (ECB, closed)
Unknown
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BABA CONSTRUCTION508/21/2026
WESTORCHARD MANAGEMENT1107/29/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/30/2025$800K—Private party → 1847 HARRISON AVE REALTY LLC$435/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADB ASSOCIATES608/24/2026
COLOMBO ARCHITECTURAL STUDIO PC101/23/2026
VASILIOS ARTEMIOU PE102/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC DESIGN FILE503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BABA CONSTRUCTION CORPGeneral Contractor508/21/2026
DOUG'S PLBG & HTG SERV COFire Protection107/08/2026
DOUG'S PLBG & HTG SERV COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616508/24/2026
JOSE A SANTOS PE, PC3292107/14/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedBABA CONSTRUCTION CORP08/20/2026
DOB NOWMechanical SystemsPermit IssuedBABA CONSTRUCTION CORP07/28/2026
DOB NOWSprinklersPermit IssuedDOUG'S PLBG & HTG SERV CO03/13/2026
DOB NOWGeneral ConstructionPermit IssuedBABA CONSTRUCTION CORP02/12/2026
DOB NOWConstruction FencePermit IssuedBABA CONSTRUCTION CORP01/27/2026
DOB NOWPlumbingPermit IssuedDOUG'S PLBG & HTG SERV CO11/19/2025
DOB NOWGeneral ConstructionPermit IssuedBABA CONSTRUCTION CORP11/12/2025
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/04/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/04/2026Certified Sprinkler - SP - RoughingCertifiedView ↗
07/14/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/14/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/14/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/21/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/02/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
08/12/2026Post-installed AnchorsSHAHRIAR QUAYYUMspecial
08/12/2026FinalSHAHRIAR QUAYYUMprogress
08/12/2026Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
08/12/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
08/12/2026HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
08/12/2026Permanent certificateSHAHRIAR QUAYYUMenergy_progress
08/12/2026Ventilation and air distribution systemSHAHRIAR QUAYYUMenergy_progress
08/12/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
08/12/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
08/12/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
08/12/2026Heating SystemsSHAHRIAR QUAYYUMspecial
08/12/2026Mechanical SystemsSHAHRIAR QUAYYUMspecial
07/06/2026Structural Stability – Alterations of existing buildingsJose Santosspecial
07/06/2026FinalYahaira Volquez Colomboprogress
04/25/2025Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
04/25/2025HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
04/25/2025HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
04/25/2025Permanent certificateSHAHRIAR QUAYYUMenergy_progress
04/25/2025Maintenance informationSHAHRIAR QUAYYUMenergy_progress
04/25/2025HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
04/25/2025Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
03/28/2025Energy Code Compliance Inspections—progress
03/28/2025Maintenance information—energy_progress
03/28/2025HVAC-R and service water heating system controls—energy_progress
03/28/2025Permanent certificate—energy_progress
Latest 25 of 56.
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/21/2026X01012800-S1Request digital key ↗
08/21/2026X01012800-I1Request digital key ↗
08/21/2026X01012800-P2Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications23
▸DOB NOWProgress Inspector Seal & Signature9
09/23/2026X01012800-P2Open ↗
09/23/2026X01012800-P2Open ↗
08/27/2026X01012800-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/21/2026X01012800-I1Open ↗
08/21/2026X01012800-P2Open ↗
08/21/2026X01012800-S4Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/23/2026X01012800-P2Open ↗
08/30/2026X01012800-S3Open ↗
08/27/2026X01012800-I1Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/21/2026X01012800-I1Open ↗
08/21/2026X01012800-P2Open ↗
08/21/2026X01012800-P1Open ↗
Showing 3 of 7 on file for this type
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/21/2026X01012800-I1Open ↗