← Back
Three families
1849 EAST 13 STREET
BROOKLYN · Gravesend (East)-Homecrest · BIN 3183964
💬 Discuss this project
1970Year Built
3Stories
C0Building Class
R5BZoning
2,920 sfGross Floor Area
3Units
7 Open Violations 6 unresolved · 1 paperwork only ▸
Three families · 2,000 sf lot · 1.46 FAR built · Flood zone X
Locations of Work
Architecture
Site & exterior1p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/01/2024$1.5M—— → —$514/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AHT ENGINEERING PLLC105/26/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AHT ENGINEERING PLLC8836105/26/2026
Building Lifecycle
All (17)Filed (1)Permit Issued (1)Signed Off (1)Violation (7)Objection (2)Special Inspection (5)
08/25/2026
Signed off — Alteration
INSTALLATION OF NEW WINDOWS & BRICKWORK ALONG FRONT FACADE. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01404856-I1
08/24/2026
Permit issued — General Construction
B01404856-I1-GC
06/23/2026
Objection resolved — Resolved
06/18/2026
Objection raised — Other
05/26/2026
Filed — Alteration
INSTALLATION OF NEW WINDOWS & BRICKWORK ALONG FRONT FACADE. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01404856-I1
05/26/2026
Special inspection requirement — Masonry
ABRAHAM TAWIL
05/19/2026
Special inspection requirement — Final
ABRAHAM TAWIL
05/19/2026
Special inspection requirement — Fenestration areas
ABRAHAM TAWIL
05/19/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
ABRAHAM TAWIL
05/19/2026
Special inspection requirement — Fenestration air leakage
ABRAHAM TAWIL
05/11/2026
Violation issued (ECB, open)
Construction
03/14/2026
Violation issued (HPD, open)
B
03/14/2026
Violation issued (HPD, open)
B
03/14/2026
Violation issued (HPD, open)
B
03/06/2026
Violation issued (HPD, open)
B
03/06/2026
Violation issued (HPD, open)
B
03/06/2026
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNot Applicable08/24/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/26/2026MasonryABRAHAM TAWILspecial
05/19/2026FinalABRAHAM TAWILprogress
05/19/2026Fenestration areasABRAHAM TAWILenergy_progress
05/19/2026Fenestration and door U-factor and product ratingsABRAHAM TAWILenergy_progress
05/19/2026Fenestration air leakageABRAHAM TAWILenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B01404856-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026B01404856-I1Open ↗
08/29/2026B01404856-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026B01404856-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026B01404856-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026B01404856-I1Open ↗