← Back
Miscellaneous hospital / health care facility
185-17 HILLSIDE AVENUE
QUEENS · Jamaica Estates-Holliswood · BIN 4213293
💬 Discuss this project
1950Year Built
1Stories
I9Building Class
R7AZoning
1,680 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Miscellaneous hospital / health care facility · Owner of record: 185 HILLSIDE HOUSING DEVELOPEMENT FUND CORPORATION · 16,000 sf lot · 0.11 FAR built · Flood zone X
Locations of Work
StructuralMechanicalFire Protection
Roof3p · 2 filings · 20 docs
Floor 91p · 1 filing · 20 docs
Floor 81p · 1 filing · 20 docs
Floor 71p · 1 filing · 20 docs
Floor 61p · 1 filing · 20 docs
Floor 5
Floor 4
Floor 3
Floor 2
Floor 12p · 1 filing · 20 docs
Cellar1p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/27/2025$7.0M—Private party → 185 HILLSIDE HOUSING DEVELOPMENT FUND CORPORATION$4,196/sf building
03/25/2014$3.2M—Private party → 18517 HILLSIDE LLC$1,905/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DAVID KOYSMAN204/07/2026
MONICA LOPEZ ARCHITECT, LLC502/09/2026
FADY HABEEL101/30/2026
H & O ENGINEERING, DPC308/14/2025
CITYSCAPE ENGINEERING, PLLC406/16/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CORE CONSULTANTS NYC1003/21/2026
EXPEDITE DEM603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MC SUPERSTRUCTURE INCGeneral Contractor104/09/2026
VOLK INDUSTRIAL SERVICESGeneral Contractor104/09/2026
Building Lifecycle
All (72)Filed (15)Permit Issued (2)Violation (1)Objection (24)Special Inspection (30)
05/11/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
04/13/2026
Objection resolved — Resolved
04/07/2026
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-P2
04/07/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
03/25/2026
Special inspection requirement — Metering
03/16/2026
Objection resolved — Addressed
03/10/2026
Special inspection requirement — Lighting controls
03/10/2026
Special inspection requirement — Interior lighting power
03/10/2026
Special inspection requirement — Lighting in dwelling units
03/10/2026
Special inspection requirement — Exterior lighting power
03/10/2026
Special inspection requirement — Electrical motors and elevators
02/24/2026
Special inspection requirement — Maintenance information
02/09/2026
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-P1
02/02/2026
Permit issued — Sidewalk Shed
Q01349996-I1-SH
02/02/2026
Objection resolved — Resolved
02/02/2026
Objection resolved — Addressed
01/30/2026
Filed — Alteration
Q01349996-I1
01/29/2026
Objection resolved — Resolved
01/29/2026
Objection resolved — Addressed
01/29/2026
Objection resolved — Addressed
01/29/2026
Objection resolved — Resolved
09/02/2025
Objection raised — Admin
08/15/2025
Permit issued — Construction Fence
Q01242004-S2-FN
08/14/2025
Filed — Full Demolition
mechanical means will assist with full demolition.
Q01242004-S2
08/14/2025
Filed — Full Demolition
mechanical means will assist with full demolition.
Q01242004-S1
08/13/2025
Special inspection requirement — Maintenance information
08/13/2025
Special inspection requirement — Air barrier — testing
08/13/2025
Special inspection requirement — Vestibules
08/13/2025
Special inspection requirement — Protection of exposed foundation insulation
08/13/2025
Special inspection requirement — Air barrier continuity plan testing
08/12/2025
Filed — Full Demolition
mechanical means will assist with full demolition.
Q01242004-I1
07/08/2025
Objection resolved — Addressed
07/08/2025
Objection resolved — Addressed
07/08/2025
Objection resolved — Addressed
07/08/2025
Objection resolved — Resolved
07/02/2025
Objection raised — Structural
07/02/2025
Objection raised — Structural
07/02/2025
Objection raised — Mechanical
07/02/2025
Objection raised — Other
07/02/2025
Objection raised — Other
07/02/2025
Objection raised — Other
07/02/2025
Objection raised — Zoning
07/02/2025
Objection raised — Admin
07/02/2025
Objection raised — Other
07/02/2025
Objection raised — Admin
07/02/2025
Objection raised — Structural
06/24/2025
Special inspection requirement — Maintenance information
06/17/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S5
06/16/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S3
06/16/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S2
06/16/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S6
06/16/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S7
06/16/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S4
06/16/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S9
06/16/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-S1
06/11/2025
Filed — New Building
FOUNDATION/EARTHWORK IN CONJUNCTION WITH NEW BUILDING JOB NUMBER #Q01226562-I1
Q01226562-I1
06/10/2025
Special inspection requirement — Heating Systems
06/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/10/2025
Special inspection requirement — Post-installed Anchors
06/10/2025
Special inspection requirement — Energy Code Compliance Inspections
Latest 60 of 72 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedMC SUPERSTRUCTURE INC02/02/2026
DOB NOWConstruction FencePermit IssuedVOLK INDUSTRIAL SERVICES08/15/2025
BISMHISSUEDPEROTTO ASSOC.10/06/1993
1 project · most recent 04/07/2026
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/07/2026——Air Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Lg ARNU053SJS4 6,100 BTU · Vrf Indoor ×1
ARNU363M2A4 40,600 BTU · Vrf Indoor ×1
ARNU483NKA4 54,000 BTU · Vrf Indoor ×1
ARUM096BTE5 108,000 BTU · Vrf Outdoor ×1
KUSAP241A 24,000 BTU · Vrf Outdoor ×1
Heat / Cool
Ice Air 8RSXC09-DH 8,000 BTU · Heat Pump Outdoor ×349
Heating
Qmark CU945 500 CFM · Electric Heater ×1
HBB1000 3,413 BTU · Electric Heater ×1
HBB750 2,560 BTU · Electric Heater ×1
IUH-520 270 CFM · Electric Heater ×1
Ventilation
Captiveaire CAS-HVACI-E.152-13-5T-DOAS 678 CFM · Rooftop Unit ×1
2 projects · most recent 05/03/2026
FiledStatusContractorScope
05/03/2026Permit IssuedNASH ELECTRIC SERVICES IN—
02/02/2026CompleteNASH ELECTRIC SERVICES IN—
1 project · most recent 04/07/2026
Steel Concrete Masonry
FiledStatusContractorScope
04/07/2026——Steel, Concrete, Masonry
▾Special Inspection Requirements (DOB NOW) — 60
DateRequirementInspectorRole
05/11/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
04/07/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
03/25/2026Metering—energy_progress
03/10/2026Lighting controls—energy_progress
03/10/2026Interior lighting power—energy_progress
03/10/2026Lighting in dwelling units—energy_progress
03/10/2026Exterior lighting power—energy_progress
03/10/2026Electrical motors and elevators—energy_progress
02/24/2026Maintenance information—energy_progress
08/13/2025Maintenance information—energy_progress
08/13/2025Air barrier — testing —energy_progress
08/13/2025Vestibules—energy_progress
08/13/2025Protection of exposed foundation insulation—energy_progress
08/13/2025Air barrier continuity plan testing—energy_progress
06/24/2025Maintenance information—energy_progress
06/10/2025Heating Systems—special
06/10/2025Fire-Resistant Penetrations and Joints—special
06/10/2025Post-installed Anchors—special
06/10/2025Energy Code Compliance Inspections—progress
06/10/2025HVAC-R and service water piping design and insulation—energy_progress
06/10/2025HVAC-R and service water heating equipment—energy_progress
06/10/2025HVAC-R and service water heating system controls—energy_progress
06/10/2025Fenestration air leakage—energy_progress
06/10/2025Air barrier - visual inspection—energy_progress
06/10/2025Fenestration and door U-factor and product ratings—energy_progress
Latest 25 of 60.
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/20/2026Q01226562-P2Request digital key ↗
08/20/2026Q01226562-S7Request digital key ↗
08/20/2026Q01226562-S6Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits3
▸BISBPP-5 - Authorization to the Department of Transportation2
02/10/2026440823753Open ↗
02/03/2026440823753Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
07/17/2025440823753Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01226562-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026Q01226562-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01226562-I1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/20/2026Q01226562-S7Open ↗
08/20/2026Q01226562-S6Open ↗
08/20/2026Q01226562-S5Open ↗
Showing 3 of 15 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
07/17/2025440823753Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/17/2025440823753Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
11/05/2025440823753Open ↗
07/29/2025440823753Open ↗
▸BISSTREET TREES SITE PLAN1
02/02/2026440823753Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01226562-I1Open ↗
▸Environmental & Asbestos2
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
02/02/2026440823753Open ↗
▸DOB NOWOER: Notice to Proceed1
08/13/2026Q01226562-I1Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
07/17/2025440823753Open ↗
▸Other Documents6
▸DOB NOWProperty Ownership Certification2
08/20/2026Q01226562-I1Open ↗
08/13/2026Q01242004-I1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
11/05/2025440823753Open ↗
▸DOB NOWStructure Photographs1
08/13/2026Q01242004-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01226562-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01226562-I1Open ↗