ECB08/11/2026OBS. FACADE WORK IN PROGRESS AT 25 STORY BLDG. UPON REQUEST, COMPETENT PERSON FAILED TO PROVIDE REQ'D DRAWINGS/CD5, PERIODIC INSP. LOGS, 6-MO SWS INSP. LETTER, PRE/POST-INSTALL. & INSTALLATION INSP. REPORTS FOR
ECB08/11/20263314.4.3.1.1 OBS. PARAPET CLAMPS IN USE AT NEIGHBORING ROOF BETWEEN EXP. 1 & 4 AS RIGGING SUPPORT. UPON REQUEST, COMPETENT PERSON FAILED TO PROVIDE RDP/PE LETTER/REPORT VERIFYING PARAPET CAPACITY AND APPROVAL
ECB08/11/20263314.4.5.4 OBS. WORKER PERFORMING WORK FROM SUSPENDED SCAFFOLD W/O REQ'D 16-HR SUSPENDED SCAFFOLD USER TRAINING/CARD. UPON REQUEST, WORKER FAILED TO PROVIDE CERT./ID, LEFT SCAFFOLD TO RETRIEVE CARD & COULD NOT
ECB08/11/20263301.1.3 OBS. SUPPORTED & SUSPENDED SCAFFOLD SYSTEMS IN USE. UPON REQUEST, CONTRACTOR FAILED TO PROVIDE MFR. SPECS FOR 1,200-LB MONORAIL/COUNTERWEIGHT SYSTEM AND SUSPENDED SCAFFOLD MOTORS/PLATFORMS. REQ'D MANUF
ECB08/11/2026OBS. SUSPENDED SCAFFOLD IN USE AT EXP. 1 W/O DIRECT SUPERVISION OF A LICENSED RIGGER OR DESIGNATED RIGGING FOREMAN. UPON REQUEST, WORKERS WERE UNABLE TO PROVIDE/IDENTIFY A RIGGING FOREMAN ON SITE WHILE SCAFFOLD
HPD11/07/2025§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING AND THE SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, NORTH WALL, WEST WALL AND EAST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2005 HMC: REFIT WINDOW FRAME OF 2ND WINDOW FROM NORTH AT EAST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT THE NORTH WALL AND EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2005 HMC: REFIT DOOR FRAME TO DOOR LEADING TO TERRACE AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT THE SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE FEET AT THE NORTH WALL, SOUTH WALL, WEST WALL AND EAST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/07/2025§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, NORTH WALL, AND EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD03/19/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD06/12/2024§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AND ASSEMBLY IN THE ENTRANCE LOCATED AT APT 25B, 26th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD02/28/2024§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, WEST WALL AND EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB08/22/2023AT THE TIME OF INSPECTION, I OBSERVED THAT TIE-BACK LINES WERE CONNECTED TO ANGLE PLATES SECURED TO THE FLOOR OF THE ROOF; UPON REQUEST FOR THE REQUIRED PULL TEST DOCUMENTS, NONE WAS PROVIDED: STOP ALL USE OF O$1K due
ECB08/22/2023AT THE TIME OF INSPECTION, I OBSERVED THAT THERE WAS NO DOB LICENSED RIGGER FOREMAN ON SITE WHILE A SUSPENDED SCAFFOLD WAS ACTIVELY IN USE; UPON REQUEST TO IDENTIFY THE DESIGNATED RIGGER FOREMAN NONE WAS AVAILA$625 due
ECB02/24/2023NOTE:OBSERVED 23 STORY BUILDING WITH SIDEWALK SHED AT EXP #1 DETERIORATED MUDSILLS 1 STEEL BEAM BENT APROX 2 INCHES CREATING HAZARD FOR PUBLIC WITH ITS STRUCTURAL INTEGRITY.REMEDY:REPLACE & SECURE MUDSILLS & ST$1K due
ECB02/08/2023OBSERVED WORKER ON ROOF WITH NO / MISSING GUARDRAILS, OBSERVED PARAPET REMOVED AT EXPOSURE # 3 WITH NETTING PLACED ACROSS ROOF WITHOUT SUFFICIENT GUARDRAILS, I ALSO OBSERVED NETTING ACROSS ROOF AT EXP.#1 WHICH$5K due
ECB02/08/2023UPON REACHING THE SIDEWALK SHED DECK, I OBSERVED MASONRY DEBRIS APPROX. 10 FT X 10FT X 3FT HIGH STORED ON SHED, I ALSO OBSERVED MATERIAL AND EQUIPMENT INCLUDING APPROX. 30 50LB COUNTERWEIGHTS. I ALSO OBSERVED T$2K due
DOB02/01/2023CYCLE 9B UNSAFE REPORT FILED
HPD04/28/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR AT EXTERIOR WALL LOCATED AT SOUTH EAST SECTION OF BUILDING AT , 25th STORY
HPD04/28/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WATERPROOF FLASHING AT BASE OF WEST WALL IN THE TERRACE LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
DOB02/16/2022FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD02/01/2022§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DEFECTIVE VINYL FLOOR TILES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
DOB11/03/2021FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES NOTE: AT ROOF PARPET WALL HAS VERTICAL CRACK AT VARIOUS LOCATION.ALSO ALL EXPOSURE BRICK WORK HAS NOT BEEN DONE YET,PROTECTION IS NOT ADEQUATE REMEDY:MAINTAIN EXTERIOR FACADE REPAIR DEFECTED FACADE.MAKE FACADE SAFE
HPD09/23/2021§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTER JOINTS AT EAST FACADE , 25th STORY
HPD09/23/2021§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT DEFECTIVE BRICK AND MORTER JOINTS AT EAST FACADE , 25th STORY
HPD09/23/2021§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT CEMENT FLOOR TILES IN THE TERRACE LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD09/23/2021§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD06/10/2021§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 6;( NO TAMPER PROOF SCREWS) IN THE ENTIRE APARTMENT LOCATED AT APT 18B, 18th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/31/2018§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25B, 25th STORY, APARTMENT AT EAST
DOB01/08/2018EXP 2 BRICK MASONRY WALL HAS SIGNIFICANT CRACKS AT 1STFL.WALL IS NON LOAD BEARING W/RESPECT TO BLDG BUT DOES SERVE AS FIRE PARTITION BET ITSELF&ADJ BLDG.WALL WILL BE DEMO PURSUANT TO DOB ORDER#111317FEU10801 AD AFTER BLDG WILL NO LONGER BE CODE COMPLIANT.REMEDY:OWN CONSTRUCT NEW EXP 2 WALL.WRK BE PERFORM UND PERM BY DOB REG CONT'R
DOB12/15/2017V-DOB VIOLATION - ACTIVE
DOB11/09/2017FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. NOTED: BUILDING HAS BEEN RENDERED NON-COMPLIANT DUE TO COMPROMISE CONDITION OF 300 E 96TH STREET
DOB08/17/2012FILE UNSAFE REPORT CYCLE 7
DOB11/30/2007V-DOB VIOLATION - ACTIVE
DOB08/09/2007V-DOB VIOLATION - ACTIVE
ECB06/30/20263307.6.5.1 OBS @EXPOSURE 3 OVERHEAD PROTECTION WORK AREA INCOMPLETE& NOT MAINTAINED IN SAFE CONDITION JUNIOR BEAMS NOT INSTALLED& SECURE PROPERLY CROSS BRACES ARE MISSING&HAVE MULTIPLE LOCATIONS PLANKS ARE UNINHearing held — result not yet published$5K proposed
ECB06/30/2026OBSERVED AT EXPOSURES,2, 3 AND 4 INADEQUATE HOUSEKEEPING CONSISTING OF PLYWOOD, STYROFOAM, GARBAGE BAGS NOT PLACED IN APPROVED CONTAINERS, AND SCATTERED DEBRIS THROUGHOUT THE WORK AREA. MATERIALS WERE NOT PROPEHearing held — result not yet published$2K proposed
ECB06/30/20263301.7 OBSERVED ACTIVE CONSTRUCTION AT A 25-STORY ALTERATION PROJECT WITH WORK IN PROGRESS ON THE 10TH AND 22ND-25TH FLOORS. UPON REQUEST, THE COMPETENT PERSON AND SPECIAL RIGGER FAILED TO PRODUCE APPROVED CONSHearing held — result not yet published$5K proposed
ECB06/30/2026OBSERVED AT EXPOSURE 3 THAT THE REQUIRED CONTROLLED ACCESS ZONE (CAZ), AS INDICATED ON THE APPROVED SITE SAFETY PLAN UNDER JOB NO. 140243626, WAS NOT ESTABLISHED. OVERHEAD PROTECTION WAS USED TO STORE GARBAGE,Hearing held — result not yet published$625 proposed
ECB06/30/20263314.4.5.4 OBSERVED WORKER LUIS A. MOROCHO PERFORMING FACADE WORK FROM A SUSPENDED SCAFFOLD WITHOUT EVIDENCE OF COMPLETING THE REQUIRED NYC DOB-APPROVED 16-HOUR SUSPENDED SCAFFOLD USER TRAINING COURSE. WORKER WHearing held — result not yet published$5K proposed
ECB04/30/2026SIDEWALK SHED NON-CONFORMING TO APPROVED CONSTRUCTION DOCUMENTS: ENTIRE BAY MISSING; POSTS MISALIGNED/UNEVEN; HEADER BEAMS BENT/DAMAGED; STORAGE ON SHED NOT PER PLANS; STEEL MEMBERS DETERIORATED; WOOD PLANKS ROHearing held — result not yet published$625 proposed
ECB04/30/2026MIS VIO 3314.10 THROUGH 3314.10.14 OBSERVED RIGGING UTILIZING ROPES AND CABLES TIED WITH KNOTS/SPLICES IN LIEU OF PROPER TERMINATIONS. NO THIMBLES, CLIPS, OR RATED HARDWARE PROVIDED. CONDITION COMPROMISES LOADHearing held — result not yet published$5K proposed
ECB11/15/2021SEC. BC 3309.1 FAILURE TO PROVIDE ADEQUATE ROOF PROTECTION AT ADJOINING PROPERTY. NOTE: AT THE TIME OF INSPECTION,OBSERVED AT EXP#2,NORTH ELEVATION INADEQUATE ROOF PROTECTION ON ALONG ROOF ON THE NORTH SIDE OFNothing owed — awaiting certificate of correction