← Back
Two family frame
1855 73 STREET
BROOKLYN · BIN 3158550
💬 Discuss this project
1925Year Built
2Stories
B2Building Class
R5Zoning
2,432 sfGross Floor Area
2Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Two family frame · 2,325 sf lot · 1.05 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction4p · 1 filing · 15 docs
Floor 1Under Construction4p · 1 filing · 15 docs
CellarUnder Construction4p · 1 filing · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/11/2025$1.6M—Private party → JK 1855 INC$678/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A PLUS DESIGN INC304/17/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A PLUS DESIGN INC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor104/09/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A PLUS DESIGN INC6615304/17/2026
Building Lifecycle
All (18)Filed (3)Permit Issued (2)Violation (5)Inspection (8)
05/05/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/05/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/01/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/17/2026
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 26587/1924)
B01339570-P1
04/15/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
02/18/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
02/18/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/18/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/18/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/10/2026
Permit issued — Plumbing
B01339570-S1-PL
01/09/2026
Permit issued — General Construction
B01339570-I1-GC
01/06/2026
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 26587/1924)
B01339570-S1
01/06/2026
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 26587/1924)
B01339570-I1
11/24/2025
Violation issued (HPD, open)
I
11/08/2019
Violation issued (HPD, closed)
I
08/23/2018
Violation issued (ECB, closed)
Construction
06/24/2018
Violation issued (HPD, open)
B
06/24/2018
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCATMAN PLUMBING INC02/10/2026
DOB NOWGeneral ConstructionPermit IssuedKALE CONSTRUCTION INC01/09/2026
1 project · most recent 04/17/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/17/2026Permit IssuedCATMAN PLUMBING INCGas, Water/Sanitary
1 project · most recent 02/10/2026
General Wiring
FiledStatusContractorScope
02/10/2026Permit IssuedW 8 ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
05/05/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/05/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/01/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/15/2026Pass-Final PL - UndergroundPassView ↗
02/18/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
02/18/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/18/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/18/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
01/06/2026Fire-Resistant Penetrations and JointsHONGTENG CHENspecial
01/06/2026FinalHONGTENG CHENprogress
01/06/2026Energy Code Compliance InspectionsHONGTENG CHENprogress
01/06/2026Fire-Resistance Rated ConstructionHONGTENG CHENprogress
01/06/2026Interior lighting powerHONGTENG CHENenergy_progress
01/06/2026Air barrier - visual inspectionHONGTENG CHENenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026B01339570-S1Request digital key ↗
08/17/2026B01339570-I1Request digital key ↗
08/17/2026B01339570-P1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature5
08/25/2026B01339570-I1Open ↗
08/25/2026B01339570-I1Open ↗
08/25/2026B01339570-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026B01339570-I1Open ↗
08/17/2026B01339570-S1Open ↗
08/17/2026B01339570-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B01339570-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026B01339570-P1Open ↗
08/17/2026B01339570-I1Open ↗
08/17/2026B01339570-S1Open ↗