← Back
Two family converted from one family
187-16 MANGIN AVENUE
QUEENS · St. Albans · BIN 4221671
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R2Zoning
1,388 sfGross Floor Area
2Units
21 Open Violations 17 unresolved · 4 paperwork only ▸FDNY Report ↗
Two family converted from one family · Owner of record: 121-03 SUTPHIN LLC · 3,000 sf lot · 0.46 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 1Under Construction1p · 1 filing · 9 docs
CellarUnder Construction1p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CIRCLE GROUP COMPANY507/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/17/2024$440K—Private party → 121-03 SUTPHIN LLC$317/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BCD CONSULTANT204/11/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SEVA PROPERTY DEVLOPMENTGeneral Contractor107/08/2026
Building Lifecycle
All (41)Filed (2)Permit Issued (1)Violation (30)Objection (6)Special Inspection (2)
05/03/2026
Objection raised — Zoning
05/03/2026
Objection resolved — Resolved
04/11/2026
Filed — Alteration
To legalize the plumbing fixtures in cellar and to remove gas range and gas line to the gas range from cellar in order to comply with violation # 335197833Y, 34594291L and other violations related to these violations.
Q01279966-S2
04/06/2026
Special inspection requirement — Energy Code Compliance Inspections
umer shah
03/11/2026
Permit issued — General Construction
Q01279966-I1-GC
12/15/2025
Objection resolved — Addressed
12/15/2025
Objection resolved — Addressed
12/09/2025
Objection raised — Scope
12/09/2025
Objection raised — Cost
11/03/2025
Filed — Alteration
To legalize the plumbing fixtures in cellar and to remove gas range and gas line to the gas range from cellar in order to comply with violation # 335197833Y, 34594291L and other violations related to these violations.
Q01279966-I1
09/30/2025
Special inspection requirement — Energy Code Compliance Inspections
INDARDEO PARBHUNATH
03/27/2017
Violation issued (ECB, closed)
Construction
03/26/2017
Violation issued (ECB, closed)
Construction
03/20/2017
Violation issued (ECB, closed)
Construction
01/24/2017
Violation issued (ECB, closed)
Construction
12/09/2016
Violation issued (ECB, closed)
Construction
11/02/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/16/2016
Violation issued (ECB, closed)
Construction
08/08/2016
Violation issued (ECB, open)
Construction
08/08/2016
Violation issued (ECB, open)
Quality of Life
03/30/2012
Violation issued (HPD, open)
B
03/30/2012
Violation issued (HPD, closed)
C
03/30/2012
Violation issued (HPD, open)
B
03/30/2012
Violation issued (HPD, open)
B
03/30/2012
Violation issued (HPD, open)
B
03/30/2012
Violation issued (HPD, open)
B
03/30/2012
Violation issued (HPD, open)
B
03/06/2012
Violation issued (HPD, closed)
C
11/07/2009
Violation issued (HPD, open)
B
11/07/2009
Violation issued (HPD, open)
B
11/07/2009
Violation issued (HPD, open)
B
11/07/2009
Violation issued (HPD, open)
C
11/07/2009
Violation issued (HPD, open)
B
11/07/2009
Violation issued (HPD, open)
B
11/07/2009
Violation issued (HPD, open)
B
11/07/2009
Violation issued (HPD, open)
B
07/16/2008
Violation issued (ECB, closed)
Construction
02/04/2008
Violation issued (ECB, open)
Unknown
10/03/2007
Violation issued (ECB, open)
Quality of Life
06/01/2001
Violation issued (HPD, open)
C
06/01/2001
Violation issued (HPD, open)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedSEVA PROPERTY DEVLOPMENT03/11/2026
1 project · most recent 04/11/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/11/2026——Gas, Water/Sanitary
1 project · most recent 03/21/2026
General Wiring
FiledStatusContractorScope
03/21/2026Permit IssuedDNR ELECTRIC INCORPORATEGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
04/06/2026Energy Code Compliance Inspectionsumer shahprogress
09/30/2025Energy Code Compliance InspectionsINDARDEO PARBHUNATHprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01279966-S2Request digital key ↗
08/17/2026Q01279966-I1Request digital key ↗
08/17/2026Q01279966-S1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026Q01279966-S2Open ↗
08/17/2026Q01279966-S1Open ↗
08/17/2026Q01279966-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026Q01279966-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026Q01279966-S1Open ↗
08/17/2026Q01279966-S2Open ↗
08/17/2026Q01279966-I1Open ↗