HPD07/27/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/27/2026§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH AND EAST WALL AT PUBLIC HALL, 1st STORY
HPD07/27/2026§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE
HPD07/27/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SLOPED WOOD FLOORING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/27/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT SOUTH AND EAST WALL AT PUBLIC HALL, 1st STORY
HPD07/27/2026§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRING AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 5F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD07/27/2026§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
ECB11/21/2025OBSERVED IN BASEMENT TWO NEWLY INSTALLED GAS-FIRED HOT WATER HEATERS, ALL MANUFACTURED IN 2023, CONNECTED TO EXISTING WATER PIPING AND GAS PIPING. ALL WORK WAS PERFORMED WITHOUT PERMITS ON FILE WITH THE DEPARTM$1K due
HPD09/23/2025§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME IN THE ENTRANCE LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH''
HPD03/22/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING FRONT TO THE WEST WALL IN THE FOYER LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''187 REAR''
HPD01/02/2024§ 53,187,231 M/D LAW & DEPT RULES & REG. PROVIDE MEANS OF EGRESS FROM YARD TO STREET BY FIREPROOF PASSAGEWAY FOR WHICH APPLICATION MUST BE FILED FOR APPROVAL,OR BY UNLOCKED DOOR OR GATE IN FENCE TO ADJOINING PREMISES WITH CONSENT OF ADJACENT OWNER.
HPD01/02/2024§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CINDER BLOCK WALL ERECTED AT EAST AT SOUTH YARD
HPD01/02/2024§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION TWO CLASS A APARTMENT COMBINE INTO TO ONE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD01/02/2024§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WIRE MESH UNDER SKYLIGHT, ROOF
HPD01/02/2024§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CLOSET ERECTED UNDER STAIRCASE AT PUBLIC HALL, 1st STORY
HPD04/25/2023§ 27-2005 ADM CODE PROVIDE WIRE MESH UNDER SKYLIGHT AT BULKHEAD , ROOF , 5th STORY
HPD11/19/2020§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WIRE MESH SCREEN PROTECTOR AT SKYLIGHT AT PUBLIC HALL, 5th STORY
HPD07/29/1985§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION MASONRY BLOCK EXTENSION ERECTED AT REAR OF BLDG YARD.
HPD03/08/1978§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION MASONRY ENCLOSURE ERECTED FRONT YARD AT WEST.
ECB03/14/2013SEC. FGC E.2.3, 27-905 & P115.6. GAS METERS INSTALLED IN AN IMPROPER LOCATION. OBSERVED GAS METERS AND GAS PIPING INSTALLED IN PUBLIC HALLWAYS OF A CLASS A MULTIPLE DWELLINGG. *PHOTO TAKEN*REMEDY:OBTAIN PERMITNothing owed — awaiting certificate of correction
Walk-up apt, over six families with stores · Owner of record: BSD HESTER LLC · 2,500 sf lot · 3.65 FAR built · Flood zone X