| Owner | Filings | Most Recent |
|---|---|---|
| 1872 EAST TREMONT | 8 | 03/22/2026 |
| Gopuff | 5 | 07/08/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| ARCTONE GROUP INC. - ARCHITECTS | 2 | 02/10/2026 |
| VALENTINO POMPEO ARCHITECT, P.C. | 2 | 02/12/2025 |
| LEVIN ENGINEERING PLLC | 9 | 07/25/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| LEVIN ENGINEERING PLLC | 18 | 03/21/2026 |
| ARCTONE GROUP INC ARCHITECTS | 1 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| COCHRANE PLBG & HTG | Plumbing | 4 | 07/08/2026 |
| TONY'S CONTRACTING | General Contractor | 3 | 03/21/2026 |
| ORBIT PLBG & HTG INC | Plumbing | 3 | 07/08/2026 |
| UNIVERSAL FIRE SPR LLC | Fire Protection | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| C.M. TESTING LABORATORY, | 1352 | 11 | 02/12/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | ORBIT PLBG & HTG INC | 05/16/2025 |
| DOB NOW | General Construction | Signed-off | TONY'SCONTRACTINGALP LLC | 04/23/2025 |
| DOB NOW | Plumbing | Permit Issued | COCHRANE PLBG & HTG | 02/21/2022 |
| DOB NOW | Plumbing | Permit Issued | COCHRANE PLBG & HTG | 02/08/2022 |
| DOB NOW | Plumbing | Permit Issued | COCHRANE PLBG & HTG | 11/04/2021 |
| DOB NOW | Plumbing | Permit Issued | COCHRANE PLBG & HTG | 05/05/2021 |
| DOB NOW | Sprinklers | Permit Issued | UNIVERSAL FIRE SPR LLC | 05/05/2021 |
| BIS | — | ISSUED | FREEDOM GS INC | 01/17/2022 |
| BIS | — | ISSUED | FREEDOM GS INC | 07/21/2021 |
| BIS | — | ISSUED | FREEDOM GS INC | 12/22/2020 |
| BIS | — | ISSUED | GOLDHAMMER WITTENSTEIN GOOD | 05/30/1990 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/25/2022 | — | — | Air Conditioning Systems | Cooling Trane PUMY-P36NKMU3 3 tons · Vrf Outdoor ×2 YSC120H3RHA-K7 10 tons · Condensing Unit ×2 YSD150G3RHC-K7 13 tons · Chiller ×2 YSD240G3RHC-K7 20 tons · Rooftop Unit ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/04/2021 | Permit Issued | UNIVERSAL FIRE SPR LLC | 116 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/25/2022 | Permit Issued | COCHRANE PLBG & HTG | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/02/2025 | Complete | TITANIUM ELECTRICAL CORP | General Wiring |
| 01/30/2023 | Complete | IZZO ELECTRIC INC. | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/08/2025 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 06/24/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 05/30/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 02/14/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/24/2021 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/18/2021 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/10/2021 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 08/20/2021 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 06/18/2021 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/08/2026 | Public Assembly Emergency Lighting | Olusoji Ojeyemi | progress |
| 01/27/2025 | Fire-Resistant Penetrations and Joints | JOHN SEMIOLI | special |
| 01/27/2025 | Energy Code Compliance Inspections | JOHN SEMIOLI | progress |
| 01/27/2025 | Maintenance information | JOHN SEMIOLI | energy_progress |
| 01/27/2025 | HVAC-R and service water heating system controls | JOHN SEMIOLI | energy_progress |
| 01/27/2025 | HVAC-R and service water piping design and insulation | JOHN SEMIOLI | energy_progress |
| 01/27/2025 | Fire-Resistant Penetrations and Joints | JOHN SEMIOLI | special |
| 01/27/2025 | HVAC-R and service water heating equipment | JOHN SEMIOLI | energy_progress |
| 07/26/2022 | Fire-Resistant Penetrations and Joints | JOHN SEMIOLI | special |
| 07/26/2022 | HVAC and service water heating system controls | JOHN SEMIOLI | energy_progress |
| 07/26/2022 | Maintenance information | JOHN SEMIOLI | energy_progress |
| 07/26/2022 | HVAC and service water heating equipment | JOHN SEMIOLI | energy_progress |
| 07/26/2022 | Post-installed Anchors | JOHN SEMIOLI | special |
| 03/04/2022 | HVAC insulation and sealing | JOHN SEMIOLI | energy_progress |
| 03/04/2022 | Mechanical Systems | JOHN SEMIOLI | special |
| 03/04/2022 | Final | JOHN SEMIOLI | progress |
| 03/04/2022 | HVAC and service water heating system controls | JOHN SEMIOLI | energy_progress |
| 03/04/2022 | HVAC and service water heating equipment | JOHN SEMIOLI | energy_progress |
| 03/04/2022 | Shutoff dampers | JOHN SEMIOLI | energy_progress |
| 03/04/2022 | Maintenance information | JOHN SEMIOLI | energy_progress |
| 03/03/2022 | HVAC and service water heating system controls | JOHN SEMIOLI | energy_progress |
| 03/03/2022 | Maintenance information | JOHN SEMIOLI | energy_progress |
| 03/03/2022 | Fire-Resistant Penetrations and Joints | JOHN SEMIOLI | special |
| 03/03/2022 | Post-installed Anchors | JOHN SEMIOLI | special |
| 03/03/2022 | HVAC and service water heating equipment | JOHN SEMIOLI | energy_progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| goBRANDS | Retail | Floor 1 | Project X01168717 |