| Owner | Filings | Most Recent |
|---|---|---|
| YONALOVE CONSULTING SERVICES | 4 | 07/08/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| BOHN ARCHITECTURE AND DESIGN | 8 | 06/25/2026 |
| LEVIN ENGINEERING PLLC | 4 | 04/30/2026 |
| ADVANCED ENGINEERING & INSPECT. PLL | 1 | 10/11/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| LEVIN ENGINEERING PLLC | 4 | 03/21/2026 |
| 4444 PPPP CORP | 12 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| M.N.C. GENERAL CONTR CORP | General Contractor | 10 | 07/08/2026 |
| NESS MECHANICAL P & H INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| CITY-WIDE TESTING INC | 416 | 8 | 04/29/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | M.N.C. GENERAL CONTR CORP | 05/27/2026 |
| DOB NOW | Construction Fence | Permit Issued | M.N.C. GENERAL CONTR CORP | 05/27/2026 |
| DOB NOW | General Construction | Permit Issued | M.N.C. GENERAL CONTR CORP | 05/22/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | MNC GENERAL CONTR CORP | 02/23/2026 |
| DOB NOW | Plumbing | Permit Issued | NESS MECHANICAL P & H INC | 01/29/2026 |
| DOB NOW | Foundation | Signed-off | MNC GENERAL CONTR CORP | 06/18/2025 |
| DOB NOW | Support of Excavation | Signed-off | MNC GENERAL CONTR CORP | 06/05/2025 |
| DOB NOW | Structural | Signed-off | MNC GENERAL CONTR CORP | 06/05/2025 |
| DOB NOW | General Construction | Permit Issued | MNC GENERAL CONTR CORP | 05/28/2025 |
| DOB NOW | Construction Fence | Permit Issued | MNC GENERAL CONTR CORP | 05/20/2025 |
| BIS | — | ISSUED | NESPO DEVELOPERS LLC | 08/30/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/30/2026 | — | — | Generators | Generators Cummins C45N6 45 kW · Generator ×1 |
| 04/28/2025 | Permit Issued | MNC GENERAL CONTR CORP | Air Conditioning Systems | Cooling Daikin RXTA48TBVJUA 4 tons · Heat Pump Outdoor ×4 RXTA36AAVJUA 3 tons · Heat Pump Outdoor ×2 RXTA48AAVJUA 4 tons · Heat Pump Outdoor ×2 RXTA60AAVJUA 5 tons · Heat Pump Outdoor ×2 RXTAQ48TBVJUA 4 tons · Vrf Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/11/2024 | — | — | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/30/2026 | — | — | Gas |
| 04/29/2026 | Permit Issued | NESS MECHANICAL P & H INC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/02/2026 | Permit Issued | STAT ELECTRIC & MAINTENAN | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/07/2025 | Permit Issued | MNC GENERAL CONTR CORP | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/26/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/15/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/08/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/19/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/19/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 02/19/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/24/2026 | Final | — | progress |
| 04/24/2026 | Mechanical Systems | — | special |
| 04/24/2026 | Emergency and Standby Power Systems (Generator) | — | special |
| 04/16/2026 | Masonry | ELIAS RASABI | special |
| 04/16/2026 | Post-installed Anchors | ELIAS RASABI | special |
| 04/16/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | ELIAS RASABI | special |
| 04/16/2026 | Energy Code Compliance Inspections | ELIAS RASABI | progress |
| 04/16/2026 | Fire-Resistance Rated Construction | ELIAS RASABI | progress |
| 04/16/2026 | Preliminary | ELIAS RASABI | progress |
| 04/16/2026 | Permanent certificate | ELIAS RASABI | energy_progress |
| 04/16/2026 | Air barrier — testing | ELIAS RASABI | energy_progress |
| 04/16/2026 | Fenestration and door U-factor and product ratings | ELIAS RASABI | energy_progress |
| 04/16/2026 | Concrete - Cast-In-Place | ELIAS RASABI | special |
| 04/16/2026 | Air barrier - visual inspection | ELIAS RASABI | energy_progress |
| 04/16/2026 | Maintenance information | ELIAS RASABI | energy_progress |
| 04/16/2026 | Interior lighting power | ELIAS RASABI | energy_progress |
| 04/16/2026 | Fenestration areas | ELIAS RASABI | energy_progress |
| 04/16/2026 | Fenestration air leakage | ELIAS RASABI | energy_progress |
| 04/16/2026 | Metering | ELIAS RASABI | energy_progress |
| 04/16/2026 | Protection of exposed foundation insulation | ELIAS RASABI | energy_progress |
| 04/16/2026 | Insulation placement and R values | ELIAS RASABI | energy_progress |
| 04/16/2026 | Electric vehicle service equipment requirements | ELIAS RASABI | energy_progress |
| 04/16/2026 | Exterior Insulation and Finish Systems (EIFS) | ELIAS RASABI | special |
| 04/16/2026 | Fire-Resistant Penetrations and Joints | ELIAS RASABI | special |
| 05/16/2025 | Final | ELIAS RASABI | progress |