← Back
Two stories - detached, small or mid-size
188-12 NASHVILLE BOULEVARD
QUEENS · St. Albans · BIN 4273974
💬 Discuss this project
1915Year Built
2Stories
A1Building Class
R2Zoning
1,184 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,000 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MASADA REALTY103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/21/2015$391K—BARCA DEVELOPMENT LLC → Private party$330/sf building
09/08/2014$216K—Private party → BARCA DEVELOPMENT LLC$182/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC205/28/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854205/28/2025
Building Lifecycle
All (11)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Special Inspection (5)
09/18/2025
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01176884-I1
05/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/29/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/29/2025
Special inspection requirement — Final
TOM PETERSEN
05/29/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
05/28/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01176884-P1
02/10/2025
Permit issued — Solar
Q01176884-I1-SL
02/05/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01176884-I1
10/03/2001
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
10/03/2001
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP02/10/2025
BISPLISSUEDWAGNER ZIV PLUMBING & HEATING06/17/2003
BISOTISSUEDO.M.L BUILDERS CO06/12/2003
2 projects · most recent 05/22/2025
FiledStatusContractorScope
05/22/2025CompleteBERGER QUALITY ELEC'L CON1 meters, 1 new_meters
02/04/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/29/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/29/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/29/2025Energy Code Compliance InspectionsTOM PETERSENprogress
05/29/2025FinalTOM PETERSENprogress
05/29/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01176884-I1Request digital key ↗
08/21/2026Q01176884-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026Q01176884-I1Open ↗
08/24/2026Q01176884-I1Open ↗
08/24/2026Q01176884-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01176884-I1Open ↗
08/21/2026Q01176884-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026Q01176884-I1Open ↗
08/24/2026Q01176884-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01176884-P1Open ↗
08/21/2026Q01176884-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01176884-I1Open ↗