← Back
Two family brick
1886 WEST 12 STREET
BROOKLYN · Gravesend (West) · BIN 3177730
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R5BZoning
2,200 sfGross Floor Area
2Units
Two family brick · 2,500 sf lot · 0.88 FAR built · Flood zone X
Locations of Work
Architecture
Floor 12p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.206/08/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H J BUILDING CONSULTING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPLEN CONSTRUCTION INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781206/08/2022
Building Lifecycle
All (22)Filed (2)Permit Issued (1)Signed Off (1)Inspection (2)Special Inspection (16)
07/19/2022
Signed off — Alteration
INTERIOR RENOVATION AT 1ST FLOOR ONLY OF EXISTING 2 STORY BUILDING WITH GENERAL CONSTRUCTION WORK AS PER PLANS FILED HERE WITH. NO CHANGE IN USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
B00717658-I1
07/12/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/14/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/09/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
06/09/2022
Special inspection requirement — Fire-Resistance Rated Construction
CHRISTIAN LOZADA
06/09/2022
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
06/09/2022
Special inspection requirement — Lighting controls
CHRISTIAN LOZADA
06/09/2022
Special inspection requirement — Maintenance information
CHRISTIAN LOZADA
06/09/2022
Special inspection requirement — Permanent certificate
CHRISTIAN LOZADA
06/09/2022
Special inspection requirement — Interior lighting power
CHRISTIAN LOZADA
06/09/2022
Special inspection requirement — Lighting in dwelling units
CHRISTIAN LOZADA
06/08/2022
Filed — Alteration
INTERIOR RENOVATION AT 1ST FLOOR ONLY OF EXISTING 2 STORY BUILDING WITH GENERAL CONSTRUCTION WORK AS PER PLANS FILED HERE WITH. NO CHANGE IN USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
B00717658-P1
06/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
06/08/2022
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
06/08/2022
Special inspection requirement — Fire-Resistance Rated Construction
CHRISTIAN LOZADA
06/08/2022
Special inspection requirement — Interior lighting power
CHRISTIAN LOZADA
06/08/2022
Special inspection requirement — Lighting in dwelling units
CHRISTIAN LOZADA
06/08/2022
Special inspection requirement — Lighting controls
CHRISTIAN LOZADA
06/08/2022
Special inspection requirement — Maintenance information
CHRISTIAN LOZADA
06/08/2022
Special inspection requirement — Permanent certificate
CHRISTIAN LOZADA
04/19/2022
Permit issued — General Construction
B00717658-I1-GC
04/14/2022
Filed — Alteration
INTERIOR RENOVATION AT 1ST FLOOR ONLY OF EXISTING 2 STORY BUILDING WITH GENERAL CONSTRUCTION WORK AS PER PLANS FILED HERE WITH. NO CHANGE IN USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
B00717658-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offSPLEN CONSTRUCTION INC04/19/2022
1 project · most recent 05/13/2026
General Wiring
FiledStatusContractorScope
05/13/2026Permit IssuedKWONG MING ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/12/2022Pass-Final General Construction Non-Directive 14PassView ↗
06/14/2022Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
06/09/2022Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
06/09/2022Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
06/09/2022Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
06/09/2022Lighting controlsCHRISTIAN LOZADAenergy_progress
06/09/2022Maintenance informationCHRISTIAN LOZADAenergy_progress
06/09/2022Permanent certificateCHRISTIAN LOZADAenergy_progress
06/09/2022Interior lighting powerCHRISTIAN LOZADAenergy_progress
06/09/2022Lighting in dwelling unitsCHRISTIAN LOZADAenergy_progress
06/08/2022Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
06/08/2022Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
06/08/2022Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
06/08/2022Interior lighting powerCHRISTIAN LOZADAenergy_progress
06/08/2022Lighting in dwelling unitsCHRISTIAN LOZADAenergy_progress
06/08/2022Lighting controlsCHRISTIAN LOZADAenergy_progress
06/08/2022Maintenance informationCHRISTIAN LOZADAenergy_progress
06/08/2022Permanent certificateCHRISTIAN LOZADAenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/29/2026B00717658-I1Request digital key ↗
08/29/2026B00717658-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00717658-I1Open ↗
08/13/2026B00717658-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/03/2026B00717658-I1Open ↗
09/03/2026B00717658-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/03/2026B00717658-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00717658-I1Open ↗