← Back
Primarily 1 family with 1 store or office
189 BROAD STREET
STATEN ISLAND · BIN 5014047
💬 Discuss this project
1931Year Built
2Stories
S1Building Class
R3-2Zoning
2,244 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Primarily 1 family with 1 store or office · Owner of record: BLOCK 541 LLC · 2,500 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 18p · 1 filing · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYCF1 PROPERTY1207/08/2026
NY COMMUNITY FINANCIAL503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEON SKVIRSKY PE203/07/2023
BICALURO ASSOCIATES PC112/22/2022
MATTHEW OSCAR ARCHITECT309/02/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILDING BROTHERS403/21/2026
CLARKE CONSTRUCTION CONSULTANTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KNOCKOUT CONSTRUCTION INC.General Contractor203/21/2026
PAUL SIGNS INCGeneral Contractor203/21/2026
RIGGING NYC CONTRACTORSElectrical103/21/2026
SCHULMAN, MElectrical103/21/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
EMPIRE STATE ELECTL CORPElectrical103/22/2026
PAUL SIGNSScaffold107/08/2026
MORRIS, DAVIDElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ROBERT PAPAZIAN ARCHITECT3491103/07/2023
WAVIC ENGINEERING PLLC1733112/22/2022
Building Lifecycle
All (39)Filed (6)Permit Issued (4)Signed Off (1)Violation (1)Inspection (3)Objection (12)Special Inspection (12)
11/26/2025
Violation issued (HPD, closed)
I
07/21/2023
Signed off — Alteration
INSTALL EXTERIOR ILLUMINATED WALL SIGN (CHECKS CASHED)
S00811766-I1
06/28/2023
Permit issued — General Construction
S00811785-I1-GC
04/12/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/14/2023
Objection raised — Scope
03/14/2023
Objection resolved — Addressed
03/08/2023
Permit issued — Sign
S00811766-I1-SG
03/07/2023
Filed — Alteration
INSTALL EXTERIOR ILLUMINATED WALL SIGN (CHECKS CASHED)
S00811766-I1
03/07/2023
Filed — Alteration
INSTALL STOREFRONT AWNING AS PER PLAN. NO TEXT OR COPY. NO CHANGE IN USE, EGRESS OR OCCUPANCY
S00811785-I1
01/12/2023
Special inspection requirement — Final
LEON SKVIRSKY
01/12/2023
Special inspection requirement — Tenant Protection Plan Compliance
Robert Papazian
01/12/2023
Special inspection requirement — Final
LEON SKVIRSKY
01/09/2023
Objection raised — Scope
01/09/2023
Objection resolved — Addressed
01/09/2023
Objection raised — Scope
01/09/2023
Objection resolved — Addressed
01/09/2023
Objection raised — Fire_Protection
01/09/2023
Objection resolved — Addressed
01/09/2023
Objection raised — Scope
01/09/2023
Objection resolved — Addressed
01/09/2023
Objection raised — Inspections
01/09/2023
Objection resolved — Addressed
12/22/2022
Filed — Alteration
PLUMBING FIXTURES IN EXISTING COMMERCIAL SPACE. NO CHANGET TO USE, OCCUPANCY OR EGRESS.
S00771078-S3
12/22/2022
Special inspection requirement — Mechanical Systems
DARIUSZ LUCZAK
12/22/2022
Special inspection requirement — Final
DARIUSZ LUCZAK
12/22/2022
Special inspection requirement — Energy Code Compliance Inspections
DARIUSZ LUCZAK
12/22/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Gheorghe Nicolescu
12/22/2022
Special inspection requirement — HVAC-R and service water heating equipment
Gheorghe Nicolescu
12/22/2022
Special inspection requirement — Maintenance information
Gheorghe Nicolescu
12/22/2022
Special inspection requirement — HVAC-R and service water heating system controls
Gheorghe Nicolescu
12/22/2022
Special inspection requirement — Permanent certificate
Gheorghe Nicolescu
12/07/2022
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/01/2022
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/30/2022
Permit issued — Plumbing
S00771078-S1-PL
09/12/2022
Permit issued — General Construction
S00771078-I1-GC
09/02/2022
Filed — Alteration
PLUMBING FIXTURES IN EXISTING COMMERCIAL SPACE. NO CHANGET TO USE, OCCUPANCY OR EGRESS.
S00771078-S1
09/02/2022
Filed — Alteration
PLUMBING FIXTURES IN EXISTING COMMERCIAL SPACE. NO CHANGET TO USE, OCCUPANCY OR EGRESS.
S00771078-S2
09/01/2022
Filed — Alteration
PLUMBING FIXTURES IN EXISTING COMMERCIAL SPACE. NO CHANGET TO USE, OCCUPANCY OR EGRESS.
S00771078-I1
07/07/2022
Special inspection requirement — Final
MATTHEW OSCAR
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedPAUL SIGNS INC06/28/2023
DOB NOWSignSigned-offPAUL SIGNS, INC03/08/2023
DOB NOWPlumbingPermit IssuedINFINITI ESC PLUMBING COR11/30/2022
DOB NOWGeneral ConstructionPermit IssuedKNOCKOUT CONSTRUCTION INC.09/12/2022
1 project · most recent 12/22/2022
Associated Ducts and Piping Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
12/22/2022Permit IssuedKNOCKOUT CONSTRUCTION INCAssociated Ducts and Piping, Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PKA-A24KA7 24,000 BTU · Split System ×1
PLA-A24EA7 24,000 BTU · Vrf Indoor ×1
1 project · most recent 12/22/2022
Water/Sanitary
FiledStatusContractorScope
12/22/2022Permit IssuedINFINITI ESC PLUMBING CORWater/Sanitary
3 projects · most recent 10/09/2024
General Wiring Lighting
FiledStatusContractorScope
10/09/2024Permit IssuedTWIN ELECTRICAL LLC3 meters, 1 new_meters
03/10/2023CompleteEMPIRE STATE ELECTL CORP—
12/01/2022Permit IssuedG.E.O. ELECTRIC CORPGeneral Wiring, Lighting
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
04/12/2023Pass-Final CND-Occupancy InspectionPassView ↗
12/07/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/01/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
01/12/2023FinalLEON SKVIRSKYprogress
01/12/2023Tenant Protection Plan ComplianceRobert Papazianspecial
01/12/2023FinalLEON SKVIRSKYprogress
12/22/2022Mechanical SystemsDARIUSZ LUCZAKspecial
12/22/2022FinalDARIUSZ LUCZAKprogress
12/22/2022Energy Code Compliance InspectionsDARIUSZ LUCZAKprogress
12/22/2022HVAC-R and service water piping design and insulationGheorghe Nicolescuenergy_progress
12/22/2022HVAC-R and service water heating equipmentGheorghe Nicolescuenergy_progress
12/22/2022Maintenance informationGheorghe Nicolescuenergy_progress
12/22/2022HVAC-R and service water heating system controlsGheorghe Nicolescuenergy_progress
12/22/2022Permanent certificateGheorghe Nicolescuenergy_progress
07/07/2022FinalMATTHEW OSCARprogress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/24/2026S00771078-S2Request digital key ↗
08/24/2026S00771078-S1Request digital key ↗
08/24/2026S00771078-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
06/16/2008510044809Open ↗
▸BISWORK PERMIT APPLICATION1
07/16/2008510044809Open ↗
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026S00811766-I1Open ↗
08/13/2026S00771078-S2Open ↗
08/13/2026S00811785-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026S00811785-I1Open ↗
08/29/2026S00771078-I1Open ↗
08/26/2026S00771078-S3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026S00811785-I1Open ↗
08/26/2026S00771078-S3Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
06/16/2008510044809Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026S00771078-I1Open ↗
08/13/2026S00771078-S3Open ↗
08/13/2026S00771078-S1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
06/16/2008510044809Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
06/16/2008510044809Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
07/16/2008510044809Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
06/16/2008510044809Open ↗