| Owner | Filings | Most Recent |
|---|---|---|
| 19 SOUTH ELLIOTT PLACE | 29 | 07/08/2026 |
| 19 S ELLIOTT PL., LLC | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/04/2022 | $3.5M | — | — → — | $970/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| CELMER ARCHITECTURE PLLC | 10 | 01/15/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| COMMERCIAL CAPITAL USA | 20 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| KAPLAN HOME IMPROVEMENT C | General Contractor | 15 | 07/08/2026 |
| ORBIT SPRINKLER CORP | Fire Protection | 1 | 07/08/2026 |
| ORBIT PLBG & HTG INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SD TESTING & INSPECTION S | 7010 | 10 | 01/15/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | KAPLAN HOME IMPROVEMENT C | 03/28/2024 |
| DOB NOW | Mechanical Systems | Signed-off | KAPLAN HOME IMPROVEMENT C | 03/28/2024 |
| DOB NOW | Structural | Signed-off | KAPLAN HOME IMPROVEMENT C | 03/28/2024 |
| DOB NOW | Structural | Signed-off | KAPLAN HOME IMPROVEMENT C | 11/08/2023 |
| DOB NOW | Mechanical Systems | Signed-off | KAPLAN HOME IMPROVEMENT C | 11/08/2023 |
| DOB NOW | General Construction | Permit Issued | KAPLAN HOME IMPROVEMENT C | 11/08/2023 |
| DOB NOW | Plumbing | Signed-off | ORBIT SPRINKLER CORP | 10/31/2023 |
| DOB NOW | General Construction | Permit Issued | KAPLAN HOME IMPROVEMENT C | 04/18/2023 |
| DOB NOW | Structural | Signed-off | KAPLAN HOME IMPROVEMENT C | 04/18/2023 |
| DOB NOW | Mechanical Systems | Signed-off | KAPLAN HOME IMPROVEMENT C | 04/18/2023 |
| DOB NOW | Plumbing | Signed-off | ORBIT PLBG & HTG INC | 04/18/2023 |
| BIS | PL | ISSUED | JOHN HLAD PLUMBING & HEATING | 06/28/1994 |
| BIS | — | ISSUED | DORF CONSTRUCTION CORP. | 05/31/1994 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/15/2025 | Permit Issued | KAPLAN HOME IMPROVEMENT C | Associated Ducts and Piping, Heating and Air Conditioning Systems, Others, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-SM48NAMHZ 48,000 BTU · Rooftop Unit ×3 Ventilation Greenheck SP-A110 75 CFM · Exhaust Fan ×6 CUBE-100HP-4 250 CFM · Kitchen Exhaust ×2 SP-A90 100 CFM · Exhaust Fan ×2 Ducts & Piping Anemostat S15H0 100 CFM · Ductwork ×1 Other Qmark sed2024 2 kW · Electric Heater ×6 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/19/2023 | Complete | FSM ELECTRICAL CORPORATIO | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/11/2025 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 12/13/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/10/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 09/06/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 12/11/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/02/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/09/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/07/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/23/2025 | Fire-Resistant Penetrations and Joints | XIUCHENG LI | special |
| 01/23/2025 | Energy Code Compliance Inspections | XIUCHENG LI | progress |
| 01/23/2025 | HVAC-R and service water piping design and insulation | XIUCHENG LI | energy_progress |
| 01/23/2025 | Post-installed Anchors | XIUCHENG LI | special |
| 01/23/2025 | Sprinkler Systems | XIUCHENG LI | special |
| 01/13/2025 | Sprinkler Systems | XIUCHENG LI | special |
| 01/13/2025 | Post-installed Anchors | XIUCHENG LI | special |
| 01/13/2025 | Fire-Resistant Penetrations and Joints | XIUCHENG LI | special |
| 01/13/2025 | HVAC-R and service water piping design and insulation | XIUCHENG LI | energy_progress |
| 01/13/2025 | Energy Code Compliance Inspections | XIUCHENG LI | progress |
| 10/30/2024 | HVAC-R and service water piping design and insulation | XIUCHENG LI | energy_progress |
| 10/30/2024 | HVAC-R and service water heating equipment | XIUCHENG LI | energy_progress |
| 10/30/2024 | Ventilation and air distribution system | XIUCHENG LI | energy_progress |
| 10/30/2024 | Permanent certificate | XIUCHENG LI | energy_progress |
| 10/30/2024 | Structural Stability – Alterations of existing buildings | XIUCHENG LI | special |
| 10/30/2024 | Fire-Resistant Penetrations and Joints | XIUCHENG LI | special |
| 10/30/2024 | Mechanical Systems | XIUCHENG LI | special |
| 10/30/2024 | Final | XIUCHENG LI | progress |
| 10/30/2024 | Energy Code Compliance Inspections | XIUCHENG LI | progress |
| 10/30/2024 | Permanent certificate | XIUCHENG LI | energy_progress |
| 10/30/2024 | Maintenance information | XIUCHENG LI | energy_progress |
| 10/30/2024 | Ventilation and air distribution system | XIUCHENG LI | energy_progress |
| 10/30/2024 | HVAC-R and service water heating equipment | XIUCHENG LI | energy_progress |
| 10/30/2024 | HVAC-R and service water heating system controls | XIUCHENG LI | energy_progress |
| 10/30/2024 | Duct leakage testing, insulation and design | XIUCHENG LI | energy_progress |