← Back
Two family brick
19 WEST 87 STREET
MANHATTAN · Upper West Side (Central) · BIN 1031461
💬 Discuss this project
1892Year Built
4Stories
B1Building Class
R7-2Zoning
6,074 sfGross Floor Area
2Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Two family brick · Owner of record: MAY 19 LLC · 2,013 sf lot · 3.02 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipmentGeneral
Roof29p · 3 filings · 20 docs
Floor 432p · 3 filings · 20 docs
Floor 334p · 4 filings · 20 docs
Floor 229p · 3 filings · 20 docs
Floor 134p · 4 filings · 20 docs
Cellar53p · 4 filings · 20 docs
Sub-Basement49p · 4 filings · 20 docs
Site & exterior9p · 2 filings · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PLATINUM SERVICES NY407/08/2026
PAUL WEISS ASSOCIATES303/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/15/2023$8.0M—Private party → MAY 19 LLC$1,317/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J CALLAHAN CONSULTING1603/21/2026
GREEN STUDIO203/21/2026
MUNICIPAL BUILDING CONSULTANTS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CONSTRUCTOMICS LLCGeneral Contractor707/08/2026
CANIDO BASONAS CONST SVCGeneral Contractor303/21/2026
AQUA PLUMBING & HTNG CORPPlumbing207/08/2026
PLATINUM SERVICES NY LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D'ANTONIO CONSULTING ENGI931908/25/2026
JSPECS,INC9429102/13/2024
THE BROOKLYN STUDIO OF AR2684102/02/2024
Building Lifecycle
All (61)Filed (11)Permit Issued (10)Signed Off (4)Violation (6)Inspection (4)Objection (10)Special Inspection (16)
08/25/2026
Filed — Alteration
This Alteration is being filed for the plumbing work at the subject premises. There are no change in use, egress or occupancy.
M00969512-P4
08/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
01/15/2026
Signed off — Alteration
M00969135-I1
12/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
12/01/2025
Filed — Alteration
This Alteration is being filed for the plumbing work at the subject premises. There are no change in use, egress or occupancy.
M00969512-P3
12/01/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
11/20/2025
Signed off — Alteration
This Alteration is being filed for the mechanical work at the subject premises as per plans submitted herewith. There are no change in use, egress or occupancy.
M00969499-I1
11/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
11/20/2025
Special inspection requirement — Mechanical Systems
GAETANO D'ANTONIO
11/20/2025
Special inspection requirement — Final
GAETANO D'ANTONIO
11/05/2025
Filed — Alteration
This Alteration is being filed for the plumbing work at the subject premises. There are no change in use, egress or occupancy.
M00969512-P2
11/05/2025
Filed — Alteration
This Alteration is being filed for the mechanical work at the subject premises as per plans submitted herewith. There are no change in use, egress or occupancy.
M00969499-P1
10/30/2025
Special inspection requirement — Mechanical Systems
GAETANO D'ANTONIO
10/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
10/30/2025
Special inspection requirement — Final
GAETANO D'ANTONIO
10/03/2025
Permit issued — General Construction
M00969135-I1-GC
09/15/2025
Signed off — Alteration
The Alteration is being filed for the structural modifications for dumbwaiter & enlarged roof hatch. There are no change in use, egress or occupancy.
M00969529-I1
08/19/2025
Permit issued — Plumbing
M00969512-I1-PL
05/05/2025
Permit issued — Mechanical Systems
M00969499-I1-MS
05/05/2025
Permit issued — General Construction
M00969135-I1-GC
03/11/2025
Filed — Alteration
This Alteration is being filed for the plumbing work at the subject premises. There are no change in use, egress or occupancy.
M00969512-P1
03/04/2025
Signed off — Alteration
M01062607-I1
02/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
01/15/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/06/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/06/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/23/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/10/2024
Permit issued — Supported Scaffold
M01072064-I1-SF
07/09/2024
Filed — Alteration
M01072064-I1
06/24/2024
Permit issued — Sidewalk Shed
M01062607-I1-SH
06/20/2024
Filed — Alteration
M01062607-I1
05/17/2024
Permit issued — Plumbing
M00969512-I1-PL
05/10/2024
Permit issued — Structural
M00969529-I1-ST
04/08/2024
Objection resolved — Addressed
04/04/2024
Permit issued — General Construction
M00969135-I1-GC
04/04/2024
Permit issued — Mechanical Systems
M00969499-I1-MS
03/26/2024
Objection resolved — Addressed
03/26/2024
Objection resolved — Addressed
03/05/2024
Objection raised — Scope
02/23/2024
Objection raised — Scope
02/23/2024
Objection raised — Scope
02/23/2024
Objection raised — Scope
02/23/2024
Objection resolved — Addressed
02/23/2024
Objection raised — Scope
02/23/2024
Objection resolved — Addressed
02/22/2024
Filed — Alteration
This Alteration is being filed for the mechanical work at the subject premises as per plans submitted herewith. There are no change in use, egress or occupancy.
M00969499-I1
02/13/2024
Filed — Alteration
The Alteration is being filed for the structural modifications for dumbwaiter & enlarged roof hatch. There are no change in use, egress or occupancy.
M00969529-I1
02/13/2024
Filed — Alteration
This Alteration is being filed for the plumbing work at the subject premises. There are no change in use, egress or occupancy.
M00969512-I1
02/13/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Jeffrey Stones
02/13/2024
Special inspection requirement — Structural Steel - Details
Jeffrey Stones
02/13/2024
Special inspection requirement — Structural Steel - Welding
Jeffrey Stones
02/02/2024
Filed — Alteration
M00969135-I1
02/02/2024
Special inspection requirement — Wood – Seismic Resistance
Jeffrey Stones
11/30/2023
Special inspection requirement — Final
Jeffrey Stones
11/30/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jeffrey Stones
12/04/2007
Violation issued (ECB, closed)
Construction
12/29/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/26/2000
Violation issued (HPD, open)
B
10/26/2000
Violation issued (HPD, open)
B
10/26/2000
Violation issued (HPD, open)
C
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offCONSTRUCTOMICS LLC10/03/2025
DOB NOWPlumbingSigned-offAQUA PLUMBING & HTNG CORP08/19/2025
DOB NOWMechanical SystemsSigned-offCONSTRUCTOMICS LLC05/05/2025
DOB NOWGeneral ConstructionSigned-offCONSTRUCTOMICS LLC05/05/2025
DOB NOWSupported ScaffoldPermit IssuedCANIDO BASONAS CONST SVC07/10/2024
DOB NOWSidewalk ShedSigned-offPLATINUM SERVICES NY LLC06/24/2024
DOB NOWPlumbingSigned-offAQUA PLUMBING & HTNG CORP05/17/2024
DOB NOWStructuralSigned-offCONSTRUCTOMICS LLC05/10/2024
DOB NOWGeneral ConstructionSigned-offCONSTRUCTOMICS LLC04/04/2024
DOB NOWMechanical SystemsSigned-offCONSTRUCTOMICS LLC04/04/2024
BISPLISSUEDN.PAGANO P&H CONTR LTD05/10/2018
BIS—ISSUEDSMI CONSTRUCTION MANGEMENT04/26/2018
BISOTISSUEDSMI CONSTRUCTION MANGEMENT04/26/2018
BISOTISSUEDSMI CONSTRUCTION MANGEMENT03/15/2018
BIS—ISSUEDSMI CONSTRUCTION MANGEMENT01/30/2018
BISOTISSUEDSMI CONSTRUCTION MANGEMENT10/16/2012
BIS—ISSUEDOLIVER COPE ARCHITECT02/11/2008
BISOTISSUEDSMI CONSTRUCTION MANGEMENT05/29/2007
BIS—ISSUEDSMI CONSTRUCTION MANGEMENT05/17/2001
BISPLISSUEDBENT MECHANICAL CORP06/19/2000
BIS—ISSUEDSMI CONSTRUCTION MANGEMENT05/08/2000
1 project · most recent 08/25/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/25/2026Signed-offAQUA PLUMBING & HTNG CORPGas, Storm, Water/Sanitary
4 projects · most recent 03/24/2026
General Wiring
FiledStatusContractorScope
03/24/2026Permit IssuedSOLAS ELECTRICAL CONTRACTGeneral Wiring
08/29/2024Permit IssuedSUPREME ELECTRIC CORPGeneral Wiring
06/17/2024CompleteILLUMINOUS ELECTRIC CORP.—
03/02/2018CompleteJOSEPH SGROI & SONS, INC.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
01/15/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/06/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/06/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/23/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
08/24/2026Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
12/08/2025Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
12/01/2025Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
11/20/2025Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
11/20/2025Mechanical SystemsGAETANO D'ANTONIOspecial
11/20/2025FinalGAETANO D'ANTONIOprogress
10/30/2025Mechanical SystemsGAETANO D'ANTONIOspecial
10/30/2025Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
10/30/2025FinalGAETANO D'ANTONIOprogress
02/25/2025Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
02/13/2024Structural Steel - High Strength BoltingJeffrey Stonesspecial
02/13/2024Structural Steel - DetailsJeffrey Stonesspecial
02/13/2024Structural Steel - WeldingJeffrey Stonesspecial
02/02/2024Wood – Seismic ResistanceJeffrey Stonesspecial
11/30/2023FinalJeffrey Stonesprogress
11/30/2023Structural Stability – Alterations of existing buildingsJeffrey Stonesspecial
▾Documents — 141 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/28/2026M00969135-I1Request digital key ↗
08/27/2026M00969499-P1Request digital key ↗
08/27/2026M00969499-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits25
▸DOB NOWLPC Approval/Permit9
09/10/2026M00969512-P4Open ↗
08/20/2026M00969512-P2Open ↗
08/20/2026M00969512-P1Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION7
05/11/2018123184918Open ↗
04/27/2018123184918Open ↗
04/27/2018123184909Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION7
04/25/2018123184918Open ↗
10/06/2017123184918Open ↗
10/05/2017123184909Open ↗
Showing 3 of 7 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
09/10/2019123184918Open ↗
03/04/2008110063314Open ↗
▸Seals & Professional Certifications34
▸DOB NOWDPL-1: Design Professional Seal & Signature11
09/10/2026M00969512-P4Open ↗
08/27/2026M00969499-P1Open ↗
08/27/2026M00969499-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/23/2026M00969512-P4Open ↗
08/28/2026M00969512-P3Open ↗
08/28/2026M00969499-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
03/17/2020123184918Open ↗
03/17/2020123184918Open ↗
03/14/2018123184909Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026M00969499-P1Open ↗
08/23/2026M00969499-I1Open ↗
08/23/2026M00969529-I1Open ↗
▸BISPC FULL REPORT1
01/16/2008110063314Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
01/16/2008110063314Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
01/22/2008110063314Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
04/25/2018123184918Open ↗
10/06/2017123184918Open ↗
▸Safety & Tenant Protection6
▸BISSTREET TREE CHECKLIST4
06/26/2020123184918Open ↗
05/28/2020123184918Open ↗
03/17/2020123184918Open ↗
Showing 3 of 4 on file for this type
▸BISTenant Protection Plan and Notes2
03/14/2018123184909Open ↗
11/29/2017123184918Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/10/2026M00969512-P4Open ↗
08/27/2026M00969499-I1Open ↗
08/27/2026M00969499-P1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
03/14/2018123184909Open ↗
09/10/2012121369508Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/16/2008110063314Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
12/04/2012121369508Open ↗
09/10/2012121369508Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/04/2012121369508Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY3
06/25/2020123184909Open ↗
06/25/2020123184909Open ↗
05/28/2020123184918Open ↗
▸BISHYDRO FLOW TEST LETTER1
03/17/2020123184918Open ↗
▸Approvals, Objections & Sign-offs19
▸BISLANDMARKS APPROVAL9
05/28/2020123184918Open ↗
03/17/2020123184918Open ↗
03/15/2018123184909Open ↗
Showing 3 of 9 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
01/04/2021123184918Open ↗
06/25/2020123184909Open ↗
06/01/2020123184918Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
09/10/2012121369508Open ↗
01/16/2008110063314Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE2
10/06/2017123184918Open ↗
10/06/2017123184918Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
01/04/2021123184918Open ↗
▸Cost, Insurance & Ownership9
▸BISCOST AFFIDAVIT9
06/26/2020123184918Open ↗
06/25/2020123184909Open ↗
03/17/2020123184918Open ↗
Showing 3 of 9 on file for this type
▸Filing & Intake Forms7
▸BISEFILING COVER SHEET3
10/06/2017123184918Open ↗
10/05/2017123184909Open ↗
09/10/2012121369508Open ↗
▸BISBOROUGH INTAKE FORM3
03/17/2020123184918Open ↗
09/10/2019123184918Open ↗
04/25/2018123184918Open ↗
▸BISADDITIONAL INFORMATION1
05/03/2018123184918Open ↗
▸Other Documents10
▸DOB NOWProof of Historic Building8
09/10/2026M00969512-P4Open ↗
08/20/2026M00969512-P1Open ↗
08/20/2026M00969512-P2Open ↗
Showing 3 of 8 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
04/27/2018123184918Open ↗
04/27/2018123184909Open ↗