← Back
Two family converted from one family
190-19 117 ROAD
QUEENS · St. Albans · BIN 4271386
💬 Discuss this project
1910Year Built
2Stories
B3Building Class
R3AZoning
1,248 sfGross Floor Area
2Units
14 Open Violations ▸FDNY Report ↗
Two family converted from one family · 2,500 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 8 docs
Floor 2Under Construction1p · 1 filing · 8 docs
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC103/17/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036103/17/2026
Building Lifecycle
All (21)Filed (1)Permit Issued (1)Violation (14)Special Inspection (5)
03/18/2026
Permit issued — Solar
Q01372326-I1-SL
03/17/2026
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01372326-I1
03/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
03/15/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
KAMRUL AHSAN
03/15/2026
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
03/15/2026
Special inspection requirement — Final
Ayracon Almaraz
03/15/2026
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
07/03/2007
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/17/2007
Violation issued (HPD, open)
C
01/17/2007
Violation issued (HPD, open)
B
01/17/2007
Violation issued (HPD, open)
C
04/03/2006
Violation issued (HPD, open)
B
04/03/2006
Violation issued (HPD, open)
B
04/03/2006
Violation issued (HPD, open)
B
11/28/2001
Violation issued (HPD, open)
B
11/28/2001
Violation issued (HPD, open)
B
11/28/2001
Violation issued (HPD, open)
B
11/28/2001
Violation issued (HPD, open)
B
11/28/2001
Violation issued (HPD, open)
B
11/28/2001
Violation issued (HPD, open)
B
11/28/2001
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedTRINITY SOLAR LLC03/18/2026
1 project · most recent 04/07/2026
FiledStatusContractorScope
04/07/2026CompleteREDLINE ELECTRIC INC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/15/2026Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
03/15/2026Structural Stability – Alterations of existing buildingsKAMRUL AHSANspecial
03/15/2026Energy Code Compliance InspectionsAyracon Almarazprogress
03/15/2026FinalAyracon Almarazprogress
03/15/2026Air barrier - visual inspectionAyracon Almarazenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026Q01372326-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
09/02/2026Q01372326-I1Open ↗
09/02/2026Q01372326-I1Open ↗
09/02/2026Q01372326-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026Q01372326-I1Open ↗
09/02/2026Q01372326-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/17/2026Q01372326-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026Q01372326-I1Open ↗