← Back
Two stories - detached, small or mid-size
190-51 103 AVENUE
QUEENS · Hollis · BIN 4232088
💬 Discuss this project
1950Year Built
2Stories
A1Building Class
R2Zoning
1,250 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 5,800 sf lot · 0.22 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof5p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC106/14/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854106/14/2024
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
08/12/2024
Signed off — Alteration
Q01061748-I1
06/27/2024
Permit issued — Solar
Q01061748-I1-SL
06/14/2024
Filed — Alteration
Q01061748-I1
06/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
06/05/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
06/05/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
06/05/2024
Special inspection requirement — Final
TOM PETERSEN
06/05/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY06/27/2024
2 projects · most recent 06/27/2024
FiledStatusContractorScope
06/27/2024CompleteBERGER QUALITY ELEC'L CON1 meters
06/09/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/05/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
06/05/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
06/05/2024Energy Code Compliance InspectionsTOM PETERSENprogress
06/05/2024FinalTOM PETERSENprogress
06/05/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01061748-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/26/2026Q01061748-I1Open ↗
08/26/2026Q01061748-I1Open ↗
08/26/2026Q01061748-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026Q01061748-I1Open ↗
08/26/2026Q01061748-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01061748-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01061748-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01061748-I1Open ↗