💬 Discuss this project
1962Year Built
34Stories
D4Building Class
R10AZoning
325,680 sfGross Floor Area
130Units
LL97 CoveredRent Stabilized11 Active Violations 10 unresolved · 1 paperwork only 1 likely answered ▸FISP: SWARMP
Elevator cooperative · Owner of record: Sol Goldman Investments · 28,589 sf lot · 11.39 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Whole building & multi-floor projectsGas piping installation2 filings
RoofSuspended scaffold for facade inspection and repair3p · 3 filings · 13 docs
Floor 35Unit 35A, Unit 35BUnder Construction3p · 2 filings · 20 docs
Floor 34
Floor 33
Floor 32Unit 32D1 filing
Floor 31Unit 31B1 filing
Floor 30Unit 29A, Unit 30A2 filings
Floor 29Unit 29B, Unit 29C2p · 2 filings
Floor 28
Floor 27Unit 27B, Unit 28CD3p · 4 filings
Floor 26Unit 26C1 filing
Floor 25Unit 25, Unit 25B, Unit 25D +11p · 3 filings
Floor 244p · 1 filing · 6 docs
Floor 23Unit 23C, Unit 23D2 filings · 20 docs
Floor 22Unit 22D2 filings
Floor 21Unit 23D1 filing
Floor 20
Floor 19Unit 19A, Unit 20AB3 filings
Floor 18
Floor 17
Floor 16
Floor 15
Floor 14Unit 14D2p · 1 filing · 15 docs
Floor 13
Floor 12Unit 12B1 filing
Floor 11Unit 11D2 filings
Floor 10
Floor 9Unit 9C, Unit 9DUnder Construction5p · 1 filing · 8 docs
Floor 8
Floor 7
Floor 6Unit 6D2 filings
Floor 5Sugared & Bronzed wall sign1 filing
Floor 4Sugared & Bronzed wall sign1 filing
Floor 3Unit 3D1 filing
Floor 2Unit 2C2 filings
Floor 1Plumbing work and waterproofing4 filings
CellarCharles H. Greenthal Management\4p · 2 filings
Sub-CellarBasement and cellar garage repairs1p · 1 filing · 5 docs
BasementGlowbar4p · 2 filings · 19 docs
Sub-BasementGlowbar3 filings
Site & exteriorCharles H. Greenthal Management\Under Construction7 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
190 East 72nd12203/21/2026
Towers East Properties4903/21/2026
Century Operating2303/21/2026
190 East 72nd St, Tenants1103/21/2026
190 East 72nd Corp % Century OP603/21/2026
190 E 72nd St Owners503/21/2026
Shareholder403/21/2026
Allen Realty Co203/21/2026
GSL Enterprises203/21/2026
Sol Goldman Investments103/22/2026
242 10th Realty103/22/2026
A&G Marble & Tile Installation103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
New Amsterdam RestorationScaffold1107/08/2026
NY Kitchen & Bath USAGeneral Contractor1104/09/2026
Adriatic Plumbing & HeatingPlumbing1007/08/2026
Align InteriorsGeneral Contractor707/08/2026
Apple RenovatorsGeneral Contractor607/08/2026
Vergara HomesGeneral Contractor603/21/2026
Reyes EnterpriseGeneral Contractor507/08/2026
Munsey EnterprisesGeneral Contractor507/08/2026
Forte GCGeneral Contractor407/08/2026
New Amsterdam Restorationspecialty_contractor307/08/2026
Manhattan Cabinetsspecialty_contractor303/21/2026
Hardesty & AssociatesGeneral Contractor303/21/2026
Plumbing & Heating DoctorPlumbing307/08/2026
A & G Marble & Tile Ins*General Contractor307/08/2026
Hardesty & AssociatesScaffold303/21/2026
Quinn-OnelliGeneral Contractor307/08/2026
Everyday MechanicalPlumbing307/08/2026
Nice PlumbingPlumbing207/08/2026
Power Surge ElectricElectrical203/22/2026
Alca RenovationsGeneral Contractor207/08/2026
Best Interiors Management CoGeneral Contractor203/21/2026
Casur Management & Maintenance*General Contractor203/21/2026
Chandrabali RamanandGeneral Contractor207/08/2026
G.R. & J Hub Home ImproveGeneral Contractor203/21/2026
NYC Design & RenoGeneral Contractor207/08/2026
Rosembarg ContractingGeneral Contractor209/24/2026
RSN InteriorsGeneral Contractor207/08/2026
A.M.NPlumbing207/08/2026
Bedrock Plumbing & HeatingPlumbing207/08/2026
JD Masters Plumbing & HeatingPlumbing207/08/2026
Master 2 Plumbing & HeatingPlumbing207/08/2026
Reliable Plumbing & HeatingPlumbing207/08/2026
Varsity Plumbing & HeatingFire Protection207/08/2026
K-Watts ElectricElectrical103/22/2026
NU-Wire ElectricElectrical103/21/2026
Transel Elev. & ElectricElectrical103/21/2026
K & G Electric CoElectrical103/22/2026
Inter Connection ElectricElectrical103/21/2026
Orbit Plumbing & HeatingPlumbing107/08/2026
Enterprise Electrical SystemsElectrical103/22/2026
Sohome WorkGeneral Contractor104/09/2026
Inter Connection EletricElectrical103/22/2026
Amko Electric Construction & Maintenance IElectrical103/21/2026
Glendale Electl ContngElectrical103/22/2026
Z-Car-DSign hanger107/08/2026
Gilston Brothers Elect'lElectrical103/22/2026
A & E PlumbingPlumbing107/08/2026
Procore MechanicalPlumbing107/08/2026
P.S.I. MechanicalPlumbing107/08/2026
BK Plumbing & Heating CoPlumbing106/27/2026
Crossfield Plumbing & HeatingPlumbing106/02/2026
Patriot ElectricElectrical103/21/2026
Hod Piping & HeatingPlumbing107/08/2026
Hudson Plumbing & MCHPlumbing106/28/2026
WCK ElectricElectrical103/22/2026
Infiniti Esc PlumbingPlumbing107/08/2026
TM Select ElectricElectrical103/21/2026
Skowronski JeffElectrical103/21/2026
VMC Plumbing & HeatingPlumbing107/08/2026
J&M Plumbing of WestchesterPlumbing107/08/2026
Stephen Fox P & HPlumbing107/08/2026
Pugliese FrankElectrical103/21/2026
Metrotech MechanicalPlumbing107/08/2026
Polyphase ElectricElectrical103/22/2026
Innsbruck InteriorsGeneral Contractor107/08/2026
KCC D+BGeneral Contractor107/08/2026
PJZ MaintenanceElectrical103/21/2026
Millar Elevator IndustriesElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Anna Jachnik Architect4202209/03/2026
Integrity Consulting Service666209/03/2026
AG Engineering8899205/22/2026
Jonathan B. Held AIA Architects1288205/22/2026
AK Engineering678209/26/2025
Philibert Engineering223209/23/2025
Framework Engineering8217109/23/2025
Urban Integrations7993209/08/2025
Niza Works of Architects6101208/02/2025
Michael Patino Architectu8170507/02/2025
Jean-Luc Briguet Architects6972105/20/2025
Biz Designs6312103/25/2025
Sia Inspections7306503/25/2025
NTD Engineering Consultan7634410/16/2024
Fsi Architecture3541010/07/2024
Assure Professional Engineering6962308/19/2024
New York Engineering Associates851207/10/2024
B Space8036306/12/2024
SGM Engineering2366102/15/2024
Structural Engineering Integ4174107/14/2023
Metric Consulting and Ins1803303/06/2023
New York Engineers3868302/27/2022
Skyline Engineering267410/19/2021
Beyond Arch3600204/27/2021
Joseph Martines PE1428308/14/2020
Jon Libasci3068105/12/2020
AZ Professional Engineering766110/15/2019
S&S Architecturtal Design2840110/10/2019
Building Lifecycle
All (300)Filed (80)Permit Issued (80)Signed Off (30)Facade (FISP) (6)Violation (44)Inspection (60)
10/13/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/23/2026
Permit issued — General Construction
M01223815-I1-GC
09/15/2026
Signed off — Alteration
M01274975-I1
09/15/2026
Signed off — Alteration
Installation of a temporary shanty per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01328082-I1
09/03/2026
Filed — Alteration
Pluming work file in conjunction with apartment #35B renovation. No change to use, egress or occupancy.
M01346775-P1
08/14/2026
Signed off — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01285155-I1
08/10/2026
Signed off — Alteration
M01278212-I1
07/28/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/14/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/12/2026
Permit issued — Sidewalk Shed
M01274975-I1-SH
06/12/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/10/2026
Signed off — Alteration
Partial apartment renovation. Minor non-structural partition demolition. Renovated kitchen & 2 bathrooms. New partitions, doors, ceilings, flooring, lighting, electrical. No change to use, egress or occupancy.
M01182276-I1
06/10/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/29/2026
Permit issued — General Construction
M01236300-I1-GC
05/22/2026
Filed — Alteration
Partial apartment renovation. Minor non-structural partition demolition. Renovated kitchen & 2 bathrooms. New partitions, doors, ceilings, flooring, lighting, electrical. No change to use, egress or occupancy.
M01182276-P1
05/12/2026
Signed off — Alteration
Partial apartment renovation. Minor non-structural partition demolition. Renovated kitchen & 2 bathrooms. New partitions, doors, ceilings, flooring, lighting, electrical. No change to use, egress or occupancy.
M01182276-S1
05/12/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/25/2026
Permit issued — General Construction
M01277310-I1-GC
04/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/21/2026
Signed off — Alteration
Filing for the plumbing work in conjunction with the renovation of the apartment.
M01052236-S1
04/20/2026
Signed off — Alteration
replace existing plumbing fixtures and install new plumbing fixtures in apt and remove one tub and change to shower
M00871286-S1
03/31/2026
Permit issued — Plumbing
M00871286-S1-PL
03/30/2026
Signed off — Alteration
Plumbing Renovation in Unit 35A- Complete (2) Bathroom, (1) Powder Room, Laundry Closet and Kitchen renovation.
M01172373-I1
03/27/2026
Signed off — Alteration
Kitchen and Bathroom renovation in 29B. No change in Use, Egress or Occupancy.
M01043784-I1
03/26/2026
Signed off — Alteration
Interior Renovation of Apartment 31B. No change in egress, occupancy or use.
M00745910-I1
03/26/2026
Signed off — Alteration
Plumbing Renovation in Unit 35A- Complete (2) Bathroom, (1) Powder Room, Laundry Closet and Kitchen renovation.
M01172373-S1
03/26/2026
Signed off — Alteration
replace existing plumbing fixtures and install new plumbing fixtures in apt and remove one tub and change to shower
M00871286-S2
03/18/2026
Permit issued — Sidewalk Shed
M01274975-I1-SH
03/17/2026
Signed off — Alteration
REMOVE EXISTING GAS DRYER IN EXISTING BATHROOM. CAP GAS BRANCH LINE AND REMOVE BRANCH TEE FOR DRYER AT MAIN GAS RISER IN APARTMENT. CAP EXISTING VENT. REPLACE EXISTING WASHER AND DRYER WITH ALL ELECTRIC TYPE. NO CHANGE IN OCCUPANCY, AREA, OR USE.
M00874864-S2
03/11/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/09/2026
Permit issued — General Construction
M01346775-I1-GC
03/02/2026
Permit issued — Plumbing
M01346775-S1-PL
02/25/2026
Filed — Alteration
REMOVE EXISTING GAS DRYER IN EXISTING BATHROOM. CAP GAS BRANCH LINE AND REMOVE BRANCH TEE FOR DRYER AT MAIN GAS RISER IN APARTMENT. CAP EXISTING VENT. REPLACE EXISTING WASHER AND DRYER WITH ALL ELECTRIC TYPE. NO CHANGE IN OCCUPANCY, AREA, OR USE.
M00874864-A5
02/19/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/06/2026
Filed — Alteration
Pluming work file in conjunction with apartment #35B renovation. No change to use, egress or occupancy.
M01346775-S1
02/06/2026
Filed — Alteration
Pluming work file in conjunction with apartment #35B renovation. No change to use, egress or occupancy.
M01346775-I1
01/21/2026
Permit issued — Plumbing
M01236300-S1-PL
01/20/2026
Signed off — Alteration
Installation of a temporary shoring per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01179861-I1
01/20/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/08/2026
Permit issued — General Construction
M01182276-I1-GC
12/19/2025
Permit issued — General Construction
M01236300-I1-GC
12/15/2025
Permit issued — Protection and Mechanical Methods
M01328082-I1-PMM
12/14/2025
Filed — Alteration
Installation of a temporary shanty per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01328082-I1
12/05/2025
Filed — Alteration
replace existing plumbing fixtures and install new plumbing fixtures in apt and remove one tub and change to shower
M00871286-P2
12/02/2025
Signed off — Alteration
GARAGE REPAIRS AS INDICATED ON THE PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01224573-I1
10/31/2025
Permit issued — General Construction
M01182276-I1-GC
10/23/2025
Filed — Alteration
Filing for the plumbing work in conjunction with the renovation of the apartment.
M01052236-P6
10/23/2025
Permit issued — General Construction
M01277310-I1-GC
10/10/2025
Signed off — Alteration
Filing for the plumbing work in conjunction with the renovation of the apartment.
M01052236-I1
09/26/2025
Filed — Alteration
PARTIAL INTERIOR RENOVATION AND COMBINATION OF EXISTING APARTMENTS ON 9TH FLOOR IN COMPLIANCE WITH TTPN 03/97. NO CHANGE TO USE, OCCUPANCY OR EGRESS
M01236300-I1
09/26/2025
Filed — Alteration
PARTIAL INTERIOR RENOVATION AND COMBINATION OF EXISTING APARTMENTS ON 9TH FLOOR IN COMPLIANCE WITH TTPN 03/97. NO CHANGE TO USE, OCCUPANCY OR EGRESS
M01236300-S1
09/24/2025
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
09/23/2025
Signed off — Alteration
PLUMBING FIXTURES INSTALLATION AND MODIFICATION AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
M01009044-I1
09/23/2025
Filed — Alteration
FACADE AND LOCAL LAW REPAIRS AS INDICATED ON THE PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY
M01277310-I1
09/23/2025
Permit issued — General Construction
M01222905-I1-GC
09/17/2025
Permit issued — Suspended Scaffold
M01278212-I1-SC
09/17/2025
Permit issued — General Construction
M01223815-I1-GC
09/12/2025
Filed — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01285155-I1
09/12/2025
Permit issued — Supported Scaffold
M01285155-I1-SF
09/09/2025
Permit issued — Sidewalk Shed
M01274975-I1-SH
Latest 60 of 300 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offRosembarg Contracting09/23/2026
DOB NOWSidewalk ShedSigned-offNew Amsterdam Restoration06/12/2026
DOB NOWGeneral ConstructionPermit IssuedAlca Renovations05/29/2026
DOB NOWGeneral ConstructionPermit IssuedNew Amsterdam Restoration04/25/2026
DOB NOWPlumbingSigned-offA & E Plumbing03/31/2026
DOB NOWSidewalk ShedSigned-offNew Amsterdam Restoration03/18/2026
DOB NOWGeneral ConstructionPermit IssuedSohome Work03/09/2026
DOB NOWPlumbingPermit IssuedCrossfield Plumbing & Heating03/02/2026
DOB NOWPlumbingSigned-offHudson Plumbing & MCH01/21/2026
DOB NOWGeneral ConstructionSigned-offQuinn-Onelli01/08/2026
DOB NOWGeneral ConstructionPermit IssuedAlca Renovations12/19/2025
DOB NOWProtection and Mechanical MethodsSigned-offNew Amsterdam Restoration12/15/2025
DOB NOWGeneral ConstructionSigned-offQuinn-Onelli10/31/2025
DOB NOWGeneral ConstructionPermit IssuedNew Amsterdam Restoration10/23/2025
DOB NOWGeneral ConstructionSigned-offNYC Design & Reno09/23/2025
DOB NOWGeneral ConstructionSigned-offRosembarg Contracting09/17/2025
DOB NOWSuspended ScaffoldSigned-offNew Amsterdam Restoration09/17/2025
DOB NOWSupported ScaffoldSigned-offNew Amsterdam Restoration09/12/2025
DOB NOWSidewalk ShedSigned-offNew Amsterdam Restoration09/09/2025
DOB NOWPlumbingSigned-offBK Plumbing & Heating Co08/27/2025
DOB NOWPlumbingSigned-offJD Masters Plumbing & Heating08/15/2025
DOB NOWGeneral ConstructionSigned-offNYC Design & Reno08/12/2025
DOB NOWGeneral ConstructionSigned-offNew Amsterdam Restoration06/12/2025
DOB NOWGeneral ConstructionSigned-offQuinn-Onelli06/05/2025
DOB NOWPlumbingSigned-offProcore Mechanical06/02/2025
DOB NOWPlumbingSigned-offJ&M Plumbing of Westchest05/30/2025
DOB NOWGeneral ConstructionSigned-offNY Kitchen & Bath USA05/12/2025
DOB NOWPlumbingSigned-offReliable Plumbing & Heating03/18/2025
DOB NOWGeneral ConstructionSigned-offA & G Marble & Tile Ins*03/06/2025
DOB NOWProtection and Mechanical MethodsSigned-offNew Amsterdam Restoration02/19/2025
DOB NOWGeneral ConstructionSigned-offChandrabali Ramanand12/20/2024
DOB NOWPlumbingPermit IssuedAdriatic Plumbing & Heating12/12/2024
DOB NOWGeneral ConstructionSigned-offA & G Marble & Tile Ins*11/25/2024
DOB NOWPlumbingPermit IssuedAdriatic Plumbing & Heating10/16/2024
DOB NOWPlumbingSigned-offAdriatic Plumbing & Heating08/30/2024
DOB NOWPlumbingPermit IssuedAdriatic Plumbing & Heating08/21/2024
DOB NOWPlumbingSigned-offAdriatic Plumbing & Heating08/09/2024
DOB NOWPlumbingSigned-offInfiniti Esc Plumbing07/31/2024
DOB NOWGeneral ConstructionSigned-offCasur Management & Maintenance*07/30/2024
DOB NOWPlumbingSigned-offAdriatic Plumbing & Heating07/26/2024
+ 60 more permits on file
2 projects · most recent 10/15/2019
Heating Systems Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/15/2019Permit IssuedHardesty & AssociatesAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric PEAD-A42AA 3 tons · Vrf Indoor ×1
Heating
Mitsubishi Electric PEAD-A36AA 3 CFM · Vrf Indoor ×1
10/10/2019Permit IssuedMunsey EnterprisesHeating Systems, Ventilation Systems
Cooling
Iec Vertical Series Fan Coils FHY 800 CFM · Fan Coil Indoor ×10
Heating
Iec Vertical Series Fan Coils FHY 800 CFM · Fan Coil Indoor ×10
1 project · most recent 07/10/2024
FiledStatusContractorScope
07/10/2024Signed-offVarsity Plumbing & Heating8 heads, 1 outlets
8 projects · most recent 05/22/2026
Water/Sanitary Gas
FiledStatusContractorScope
05/22/2026Signed-offJ&M Plumbing of WestchestGas
02/25/2026Permit IssuedAdriatic Plumbing & HeatingGas, Water/Sanitary
09/26/2025Signed-offGolds PlumbingGas, Water/Sanitary
08/02/2025Signed-offBK Plumbing & Heating CoWater/Sanitary
05/20/2025——Gas, Water/Sanitary
08/14/2020Signed-offM. Spinelli PLB & HeatingWater/Sanitary
10/15/2019Permit IssuedBedrock Plumbing & HeatingWater/Sanitary
10/07/2019Permit IssuedKypros MechanicalGas, Water/Sanitary
25 projects · most recent 07/01/2026
General Wiring Lighting
FiledStatusContractorScope
07/01/2026CompleteIkaros Electrical Enterprises—
05/19/2026CompleteKings Electric CoGeneral Wiring
03/09/2026Permit IssuedW 8 ElectricGeneral Wiring
01/18/2026Permit IssuedTM Select ElectricGeneral Wiring
11/03/2025Permit IssuedEnterprise Electrical SystemsGeneral Wiring
10/28/2025Permit IssuedK & G Electric CoGeneral Wiring
10/07/2025CompleteGlendale Electl Contng—
09/09/2025CompleteNelson & Tom Maintenance Inc DB—
08/01/2025CompleteGlendale Electl ContngGeneral Wiring
05/09/2025CompleteLina ElectricGeneral Wiring
03/28/2025CompleteCarrasco ElectricGeneral Wiring
01/29/2025CompleteWCK ElectricGeneral Wiring
12/31/2024CompleteNyco ElectricGeneral Wiring
10/07/2024CompleteIkaros Electrical Enterprises—
07/16/2024CompleteK-Watts ElectricGeneral Wiring
1 project · most recent 09/12/2025
Scaffold
FiledStatusContractorScope
09/12/2025Signed-offNew Amsterdam RestorationScaffold
1 project · most recent 08/02/2025
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
08/02/2025Signed-offNYC Design & RenoTenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 83
DateTypeResultReport
10/13/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/28/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/14/2026Pass-Final CND-Occupancy InspectionPassView ↗
06/12/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/12/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/23/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/11/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/19/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/20/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/24/2025Pass-Final Boiler Equipment InspectionPassView ↗
09/08/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/15/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/23/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
05/21/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/13/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/15/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/08/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/06/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/02/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/24/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/06/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/06/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/05/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
12/04/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
Latest 25 of 83.
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
09/14/2026Energy Code Compliance InspectionsAnna Jachnikprogress
09/14/2026Fire-Resistant Penetrations and JointsAnna Jachnikspecial
09/14/2026Post-installed AnchorsALEKSANDR LEVINspecial
09/14/2026FinalAnna Jachnikprogress
09/02/2026Post-installed AnchorsALEKSANDR LEVINspecial
09/02/2026Lighting in dwelling unitsAnna Jachnikenergy_progress
09/02/2026FinalAnna Jachnikprogress
09/02/2026Energy Code Compliance InspectionsAnna Jachnikprogress
09/02/2026Fire-Resistant Penetrations and JointsAnna Jachnikspecial
06/10/2026FinalJONATHAN HELDprogress
06/10/2026Tenant Protection Plan ComplianceARIEL GOLSHANspecial
06/10/2026Fire-Resistant Penetrations and JointsJONATHAN HELDspecial
06/10/2026Lighting controlsJONATHAN HELDenergy_progress
06/10/2026Lighting in dwelling unitsJONATHAN HELDenergy_progress
06/10/2026Interior lighting powerJONATHAN HELDenergy_progress
06/10/2026Fire-Resistance Rated ConstructionJONATHAN HELDprogress
06/10/2026Post-installed AnchorsJONATHAN HELDspecial
01/15/2026Lighting in dwelling unitsAnna Jachnikenergy_progress
08/25/2025MasonryJAMES NAPOLIspecial
08/25/2025FinalJAMES NAPOLIprogress
08/25/2025Tenant Protection Plan ComplianceJacky Philibertspecial
08/08/2025Interior lighting powerMichael Patinoenergy_progress
08/08/2025Fenestration air leakageMichael Patinoenergy_progress
08/08/2025Fenestration and door U-factor and product ratingsMichael Patinoenergy_progress
08/08/2025Fenestration areasMichael Patinoenergy_progress
Latest 25 of 150.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
GlowbarPersonal servicesSub-basement
Project M00330219 Alteration · Permit Entire · 05/13/2020
Project M00330111 Alteration · Permit Entire · 04/23/2020
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 2,061 on file (BIS + DOB NOW)
▸Plans & Drawings112
▸DOB NOWPlans/Sketch95
09/03/2026M00495850-I1Request digital key ↗
09/03/2026M00495850-S1Request digital key ↗
09/03/2026M00495850-P1Request digital key ↗
Showing 3 of 95 on file for this type
▸DOB NOWPlans/Sketch - Plumbing7
09/05/2026M00226062-I1Request digital key ↗
09/05/2026M00228044-I1Request digital key ↗
09/03/2026M00211562-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems5
09/05/2026M00226128-I1Request digital key ↗
09/04/2026M00254697-I1Request digital key ↗
Showing 2 of 5 on file for this type
▸DOB NOWPlans/Sketch - General Construction3
09/04/2026M00447166-I1Request digital key ↗
09/03/2026M00448843-P1Request digital key ↗
09/03/2026M00448843-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWPlans/Sketch - Sign1
09/04/2026M00338524-I1Request digital key ↗
▸Applications & Permits386
▸BISWORK PERMIT APPLICATION208
10/23/2020123784486Open ↗
06/11/2020123830989Open ↗
03/27/2020123784486Open ↗
Showing 3 of 208 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION176
03/16/2022101366567Open ↗
05/20/2021123784486Open ↗
05/19/2021123784486Open ↗
Showing 3 of 176 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications508
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION200
03/27/2020123784486Open ↗
03/27/2020123784486Open ↗
03/16/2020123784486Open ↗
Showing 3 of 200 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature113
10/14/2026M01346775-P1Open ↗
09/05/2026M00262451-I1Open ↗
09/05/2026M00330111-I1Open ↗
Showing 3 of 113 on file for this type
▸DOB NOWProgress Inspector Seal & Signature90
10/14/2026M01346775-P1Open ↗
10/14/2026M01346775-P1Open ↗
09/24/2026M00745910-I1Open ↗
Showing 3 of 90 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature54
10/14/2026M01346775-P1Open ↗
10/14/2026M01346775-P1Open ↗
09/24/2026M00745910-I1Open ↗
Showing 3 of 54 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM25
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 25 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST18
07/01/2019123689892Open ↗
Showing 1 of 18 on file for this type
▸BISPC FULL REPORT3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
07/01/2019123689892Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT: STATEMENT OF RESPONSIBILITY2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment191
▸BISSELF-CERT PLUMBING NOTICE68
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 68 on file for this type
▸BISSCHEDULE B - PLUMBING61
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 61 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE45
12/27/2019123527111Open ↗
12/06/2019123660010Open ↗
07/12/2019123660010Open ↗
Showing 3 of 45 on file for this type
▸BISEQUIPMENT USE PERMITS5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISSPRINKLER INSP REPORT : FP-853
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSIGN HANGER CERTIFICATE1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
07/19/2019123414787Open ↗
▸Safety & Tenant Protection35
▸BISTenant Protection Plan and Notes14
03/13/2020123830989Open ↗
09/06/2019123815755Open ↗
09/04/2019123773960Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWTenant Protection Plan14
09/04/2026M00338524-I1Open ↗
09/03/2026M00211562-I1Open ↗
09/03/2026M00211562-P1Open ↗
Showing 3 of 14 on file for this type
▸BISSTREET TREE CHECKLIST3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWAI1-accerpted #4-AI1 M00886107-I1 TPP audit resp 2403121
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos164
▸DOB NOWDEP ACP-5: Asbestos Assessment Report62
09/04/2026M00338524-I1Open ↗
09/03/2026M00495850-S1Open ↗
09/03/2026M00495850-P1Open ↗
Showing 3 of 62 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)40
03/13/2020123830989Open ↗
09/06/2019123815755Open ↗
09/04/2019123773960Open ↗
Showing 3 of 40 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'32
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 32 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form16
08/28/2026M00999011-I1Open ↗
08/27/2026M01008923-I1Open ↗
08/26/2026M01075645-I1Open ↗
Showing 3 of 16 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM3
09/26/2019123784486Open ↗
Showing 1 of 3 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISASBESTOS INSPECTION REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance143
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS77
03/16/2020123784486Open ↗
03/13/2020123830989Open ↗
03/13/2020123830989Open ↗
Showing 3 of 77 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS36
03/15/2021123547046Open ↗
02/11/2021123815755Open ↗
11/17/2020123660010Open ↗
Showing 3 of 36 on file for this type
▸BISTECHNICAL REPORT: ENERGY12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 12 on file for this type
▸BISTR8: Energy Code Progress Inspections6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY6
11/29/2021123773960Open ↗
11/24/2021123773960Open ↗
03/15/2021123547046Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.5
09/03/2026M00495850-I1Open ↗
09/02/2026M00512506-I1Open ↗
09/02/2026M00745910-I1Open ↗
Showing 3 of 5 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/24/2021123773960Open ↗
▸Inspections & Test Reports19
▸BISTECHNICAL REPORT: RESPONSIBILITY14
03/15/2022101366567Open ↗
03/15/2022101366567Open ↗
11/29/2021123773960Open ↗
Showing 3 of 14 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs122
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST59
03/22/2022101366567Open ↗
03/16/2022101366567Open ↗
11/29/2021123773960Open ↗
Showing 3 of 59 on file for this type
▸BISADMINISTRATIVE OBJECTIONS42
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 42 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION15
03/16/2020123784486Open ↗
01/29/2019123127918Open ↗
Showing 2 of 15 on file for this type
▸BISCONSTRUCTION CODE DETERMINATION2
07/02/2019123553877Open ↗
Showing 1 of 2 on file for this type
▸BISSUPERSEDING LETTER2
03/16/2020123784486Open ↗
Showing 1 of 2 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Cost, Insurance & Ownership158
▸BISCOST AFFIDAVIT156
03/18/2022101366567Open ↗
03/18/2022101366567Open ↗
11/29/2021123773960Open ↗
Showing 3 of 156 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Filing & Intake Forms183
▸BISEFILING COVER SHEET83
03/13/2020123830989Open ↗
09/26/2019123784486Open ↗
09/06/2019123815755Open ↗
Showing 3 of 83 on file for this type
▸BISADDITIONAL INFORMATION62
01/10/2020123660010Open ↗
01/08/2020123527111Open ↗
08/22/2019123527111Open ↗
Showing 3 of 62 on file for this type
▸BISBOROUGH INTAKE FORM33
10/23/2020123784486Open ↗
05/01/2020123830989Open ↗
04/13/2020123830989Open ↗
Showing 3 of 33 on file for this type
▸BISeFiling Job Application Cover Sheet5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸Other Documents22
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION15
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 15 on file for this type
▸BISDepartment of Consumer Affairs (DCA) Form3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISPLOT DIAGRAM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWCalculations1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWManufacturer's Specifications1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type