DOB01/07/2025AT THE EAST WALL ABOVE APT #3, THERE IS PEELING AND CLEAVING OF BRICK AND STUCCO WITH THE DANGER OF BEING DISPLACED TO THE REAR YARD OF APT #3. NOTED IN NOV #39134804M.
HPD08/23/2024§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BUILDING ENTRANCE WOODEN DOOR AND WINDOW FRAMES ROTTING AT VESTIBULE AT PUBLIC HALL, 1st STORY
HPD08/23/2024§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL AT PUBLIC HALL, 1st STORY
HPD08/23/2024§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH EAST AND WEST WALL AT LOBBY, 1st STORY
HPD10/03/2023§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT NORTH AND SOUTH WALL AT PUBLIC HALL, 1st STORY
HPD10/03/2023§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH AND SOUTH WALL AT PUBLIC HALL, 1st STORY
HPD09/08/2023§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGNAGE MISSING
HPD07/13/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/13/2023§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/13/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD09/12/2022§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, EAST AND WEST WALLS AT PUBLIC HALL, 1st STORY
HPD09/12/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE FIRE RETARDANT CEILING, EAST AND WEST WALLS AT PUBLIC HALL, 1st STORY
HPD07/26/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CIELING AND NORTHWALL AT PUBLIC HALL, 1st STORY
HPD07/26/2022§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEIILING AND NORTH WALL AT PUBLIC HALL, 1st STORY
HPD02/11/2022§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND NORTH WALL AT LOBBY, 1st STORY
HPD02/11/2022§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, NNORTH AND SOUTH WALLS AT LOBBY, 1st STORY
HPD02/11/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDARETARDANT CEILING AND NNORTH WALL AT LOBBY, 1st STORY
HPD06/29/2021§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE CEILING AND SOUTH WALL AT PUBLIC HALL, 1st STORY
HPD06/29/2021§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX. 4 SQ. FT. AT EAST WALL APROX. 15 SQ. FT. AT WEST WALL APROX. 8 SQ. FT. AT SOUTH WALL AT PUBLIC HALL, 1st STORY ORIGINAL VIOLATION 14417335 ISSUED 29-JUN-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD06/29/2021§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILINGAND ALL WALLS AT PUBLIC HALL, 1st STORY
HPD06/29/2021§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ON CEILING FROM EXTENTION ROOF AT PUBLIC HALL, 1st STORY
HPD06/29/2021§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
HPD06/29/2021§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT THE CEILING AND ALL WALLS AT PUBLIC HALL, 1st STORY
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
HPD09/11/2019§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL AT LOBBY, 1st STORY
HPD09/11/2019§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK FROM THE CEILING AT LOBBY, 1st STORY
DOB01/23/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB10/25/201850,5A)AS PER(B254)FOUND A BURNHAM BOILER MODEL #P203 RATED AT 62000 BTUS TO HAVE THESE VIOLATING CONDITIONS. 50)MISSING SPILL SWITCH ON DRAFT HOOD. 5A)MISSING DROPLEG ON BACKFLOW, MISSING DROP LEG ON RELIEF VAL$625 due
ECB10/25/201850,5A-AS PER (B254) FOUND A BURNHAM BOILER MODEL #203 RATED AT 62000BTUS TO HAVE THESE VIOLATING CONDITIONS. 50)NO SPILL SWITCH ON DRAFT HOOD. 5A)NO DROP LEG ON BACKFLOW, NO DROP LEG ON RELIEF VALVE. CORRECT AL$3K due
ECB10/25/201850,5A-AS PER(B254)FOUND A US BOILER MODEL X. TO HAVE THESE VIOLATING CONDITIONS. 50)NO SPILL ON DRAFT HOOD. NO DROP LEG ON BACKFLOW PREVENTER AND RELIEF VALVE. CORRECT ALL VIOLATING CONDITONS AND SUBMIT CERTIFI$625 due
ECB10/25/201816,5A,32A,50-AS PER (B254) FAILURE TO MAINTAIN. FOUND ONE BOILER BURNHAM MODEL PWB60 RATED AT 17500. 50)MISSING SPILL SWITCH AT BOILER HOOD, BOILER CANNOT BE SUPPORTED BY HOLLOW BRICKS, 16)NO POSTED BOILER NUMB$625 due
ECB10/24/2018AS PER B254 FAILURE TO MAINTAIN. FOUND ONE BOILER MODEL #4128 BURNHAM RATED AT 385000BTUS TO HAVE THESE VIOLATING CONDITIONS. 32)EXPOSED WIRING, 50)MISSING SPILL SWITCH AT DRAFT HOOD, 16)NO POSTED BOILER NUMBER$625 due
ECB10/24/201851-CLASS 1 (B154) FAILURE TO MAINTAIN FOUND HOT WATER HEATER MODEL A/OSMITH 40000 BTUS FVC40 TO BE LEAKING AND VERY DANGEROUS. CEASE USE O F APPLIANCE. RMDY: MUST REPALCE AND SUBMIT CERTIFICATE OF CORRECTION.$1K due
ECB10/24/2018AS PER CLASS (B254) FOUND A BOILER BURNHAM MODEL #203 RATED AT 62000BTQS TO HAVE THESE VIOLATING CONDITIONS. 50)MISSING SPILL SWITCH AT DRAFT HOOD. 5A)BACKFLOW TO HAVE DROP LEG-RELIEF VALVE ALSO TO HAVE DROP LE$625 due
ECB10/24/201850,5A)AS PER(B254) FAILURE TO MAINTAIN. FOUND BURNHAM BOILER MODEL #P2X3 RATED AT 62000BTUS. 50)NO SPILL SWITCH ON DRAFT HOOD. 5A)BACKFLOW MISSING DROP LEG, ALSO RELIEF VALVE MISSING DROP LEG. CORRECT ALL VIOLA$313 due
HPD09/24/2018§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK FROM THE CEILING AND SOUTH WALL AT LOBBY, 1st STORY
HPD09/24/2018§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING CEILING AT LOBBY, 1st STORY
HPD09/24/2018§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT LOBBY, 1st STORY
HPD09/24/2018§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL AT LOBBY, 1st STORY
DOB08/22/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB05/24/2018FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:@PART OF THE BLDG ROOF GUARDRAIL RUSTED BROKEN (METAL) & SHAKY PVC GUARDRAIL THE ROOF TOP HAVE ROTTEN WOODEN PLATE FORM W/NO ADEQUATE SAFETY RAILING.REM:R$1K due
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
HPD04/29/2010§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... ON THE CEILING AT PUBLIC HALL , 1st STORY
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB07/14/2007V-DOB VIOLATION - ACTIVE
DOB04/21/2004V-DOB VIOLATION - ACTIVE
DOB12/09/1996VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB08/27/1993V-DOB VIOLATION - ACTIVE
ECB04/29/2022AT TIME OF INSPECTION OBSERVED SPALLING BRICKS SURFACE, POP-UP EXTERIOR FACADE PAINT, DISREPAIR MORTAR JOINT ON EXTERIOR WALL THROUGHOUT. ALSO OBSERVED EVIDENCE OF WATER MARKS / STAIN ON LOBBY WALL & CEILING.,Nothing owed — awaiting certificate of correction