← Back
Two stories - detached, small or mid-size
1901 AVENUE H
BROOKLYN · BIN 3179142
💬 Discuss this project
1899Year Built
2.5Stories
A1Building Class
R2Zoning
2,686 sfGross Floor Area
1Units
3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: 1901 AVE H REALTY LLC · 5,075 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Permit Issued — active, not yet Signed-off
Floor 2Under Construction4p · 1 filing · 5 docs
Floor 1Under Construction3p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
50 W 27TH STREET107/08/2026
MCLAUGHLIN & STERN, LLP503/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/23/2025$1.3M—Private party → 1901 AVE H REALTY LLC$484/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BANGASH ASSOCIATES INC.104/02/2026
LUCID BUILDING ENGINEERING P.C.108/31/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRO-SERVE CONSTRUCTION COGeneral Contractor303/21/2026
ALLIED RESTORATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LUCID BUILDING ENGINEERIN8196108/31/2023
Building Lifecycle
All (15)Filed (2)Permit Issued (2)Signed Off (1)Violation (7)Special Inspection (3)
04/06/2026
Permit issued — General Construction
B01368078-I1-GC
04/02/2026
Filed — Alteration
PROPOSED INTERIOR RENOVATION OF EXISTING KITCHEN AND BATHROOMS ON THE FIRST AND SECOND FLOORS AS PER PLANS. NO CHANGE IN USE, EGRESS OR LOT COVERAGE.
B01368078-I1
03/05/2026
Special inspection requirement — Final
FAZAL BANGASH
01/19/2024
Violation issued (ECB, open)
Construction
10/23/2023
Signed off — Alteration
IED #17780 The existing chimney located exp2/3 was struck by lightning. The chimney had cracks on the brick surfaces and some of bricks fell down breaking the neighbor's window. The chimney has been down to safe level under supervision of PE.
B00923860-I1
10/18/2023
Permit issued — General Construction
B00923860-I1-GC
08/31/2023
Filed — Alteration
IED #17780 The existing chimney located exp2/3 was struck by lightning. The chimney had cracks on the brick surfaces and some of bricks fell down breaking the neighbor's window. The chimney has been down to safe level under supervision of PE.
B00923860-I1
08/23/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
YUNHO LEE
08/23/2023
Special inspection requirement — Final
YUNHO LEE
08/01/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/31/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/26/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/26/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/26/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/04/1993
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedALLIED RESTORATION04/06/2026
DOB NOWGeneral ConstructionSigned-offPRO-SERVE CONSTRUCTION CO10/18/2023
2 projects · most recent 01/19/2026
General Wiring
FiledStatusContractorScope
01/19/2026Permit IssuedWCK ELECTRIC CORP.General Wiring
06/08/2025Permit IssuedCLAIRMONT ELEC'L CONTR'GGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
03/05/2026FinalFAZAL BANGASHprogress
08/23/2023Structural Stability – Alterations of existing buildingsYUNHO LEEspecial
08/23/2023FinalYUNHO LEEprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026B00923860-I1Request digital key ↗
08/17/2026B01368078-I1Request digital key ↗
▸Applications & Permits2
▸DOB NOWLPC Approval/Permit2
08/17/2026B01368078-I1Open ↗
08/13/2026B00923860-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026B00923860-I1Open ↗
08/17/2026B01368078-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026B00923860-I1Open ↗
08/25/2026B01368078-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026B00923860-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026B00923860-I1Open ↗
08/17/2026B01368078-I1Open ↗