DOB05/14/2015FAILURE TO MAINTAIN .1STORY+CELLAR,WOOD FRAMED CMU BEARING WALL OCCUPI ED AS DAYCARE.NORTH END OF WESRT WALL FLOOR IS SLOPING+/- 2" DOWN.WOOD GIRDR 7 JOINTS FRAMING INTO IT HAVE MILD SPLITTING & DISPLACED 2"DOWN DUE TO LOCALLY DETERIOTED SUP AT CMUWALL.OWNER TO ENGAGE LICENSED PE TO PREPARE DWGS TOBE FILED WITH DOB NO LATER THAN 05/29/15
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB02/27/2001V-DOB VIOLATION - ACTIVE
ECB05/16/2017FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC10006.1.27-542.INOPERATIVE EMERGENCY LIGHTS WITH BATTERY BACKUP OVER ENTRYNothing owed — awaiting certificate of correction
ECB06/03/1991FAILURE TO PROVIDE PA PLANS APPROVED AND AVAILABLE FOR INSPECTION. REMEDY: PROVIDE APPRVED PA PLANS FOR ISNPECTION AND FRAME AND POST IN KITCHEN.Nothing owed — awaiting certificate of correction
ECB04/23/1991TWO EXIT DOORS SWING AGAINST FLOW OF EGRESS, AT PASSAGE WAY TO SECONDARY EXIT TO STREET. REMEDY: REMOVE DOOR OR HAVE DOORS SWING IN RIGHT DIRECTION WITH PROPER HARDWARE. EMERGENCY LIGHTING IS INADEQUATE DOES NONothing owed — awaiting certificate of correction
ECB04/28/1989GAS LINE DISCONNECTED CONEDISON RED TAG. BOILER ROOM NOT A STORAGE ROOM. INSTALL STACK CLEANOUT DOOR. CLEAN GAS BURNERS. REMOVE INOPERATIVE BREECHING EXTENSION AND SEAL HOLE PROPERLY. INSTALL PROPER CAST.Nothing owed — awaiting certificate of correction