← Back
BuildNYC
Two family converted from one family
192-43 HOLLIS AVENUE
QUEENS · Hollis · BIN 4232133
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R3XZoning
2,496 sfGross Floor Area
2Units
Two family converted from one family · 5,100 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Attic12p · 1 filing · 20 docs
Floor 214p · 2 filings · 20 docs
Floor 115p · 2 filings · 20 docs
Cellar15p · 2 filings · 20 docs
Site & exterior15p · 3 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/06/2022$1.3M—AVIV DEVELOPMENT CORP. → Private party$511/sf building
11/30/2021$535K—Private party → AVIV DEVELOPMENT CORP.$214/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Tabriz Group Enterprises308/24/2022
Tabriz Design Group308/11/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Tabriz Design Group603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Precision Home DevelopmentGeneral Contractor303/21/2026
Precision Home Developmentspecialty_contractor303/21/2026
Precision Home DevelopmentScaffold207/08/2026
Infiniti Esc PlumbingPlumbing107/08/2026
Sunrun Installation ServiceGeneral Contractor112/22/2022
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Tabriz Group Enterprises3275308/24/2022
Building Lifecycle
05/26/2023
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
Q00657424-I1-GC-CX
09/14/2022
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT 1 APP # Q00657424.
Q00671444-I1
08/30/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/28/2022
Special inspection requirement — Concrete - Cast-In-Place
BAKHTIAR SHAMLOO
08/28/2022
Special inspection requirement — Masonry
BAKHTIAR SHAMLOO
51 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offInfiniti Esc Plumbing06/01/2022
DOB NOWConstruction FenceSigned-offPrecision Home Development05/27/2022
DOB NOWGeneral ConstructionPermit IssuedPrecision Home Development05/26/2022
DOB NOWMechanical SystemsPermit IssuedPrecision Home Development04/05/2022
DOB NOWConstruction FenceSigned-offPrecision Home Development03/16/2022
BISOTISSUEDSunrun Installation Service12/22/2022
1 project · most recent 08/24/2022
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScope
08/24/2022Permit IssuedPrecision Home DevelopmentAir Conditioning Systems, Ventilation Systems
2 projects · most recent 12/22/2022
General Wiring
FiledStatusContractorScope
12/22/2022CompleteSunrun Solar Electl—
05/31/2022CompleteC & A ElectricalGeneral Wiring
1 project · most recent 08/24/2022
FiledStatusContractorScope
08/24/2022Permit IssuedPrecision Home Development—
1 project · most recent 08/24/2022
Earthwork
FiledStatusContractorScope
08/24/2022Permit IssuedPrecision Home DevelopmentEarthwork
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/30/2022Pass-Final CND-Occupancy InspectionPassView ↗
06/07/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/07/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/07/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/07/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 55
DateRequirementInspectorRole
08/28/2022Concrete - Cast-In-PlaceBAKHTIAR SHAMLOOspecial
08/28/2022MasonryBAKHTIAR SHAMLOOspecial
08/28/2022Mechanical SystemsBAKHTIAR SHAMLOOspecial
08/28/2022Excavations - Sheeting, Shoring, and BracingBAKHTIAR SHAMLOOspecial
08/28/2022Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
08/28/2022Fire-Resistant Penetrations and JointsBAKHTIAR SHAMLOOspecial
08/28/2022Structural Stability – Alterations of existing buildingsBAKHTIAR SHAMLOOspecial
08/28/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationBAKHTIAR SHAMLOOspecial
08/28/2022Footing and FoundationBAKHTIAR SHAMLOOprogress
08/28/2022FinalHARI SONIprogress
08/28/2022Energy Code Compliance InspectionsBAKHTIAR SHAMLOOprogress
08/28/2022Fire-Resistance Rated ConstructionBAKHTIAR SHAMLOOprogress
08/28/2022Insulation placement and R valuesBAKHTIAR SHAMLOOenergy_progress
08/28/2022HVAC-R and service water heating system controlsBAKHTIAR SHAMLOOenergy_progress
08/28/2022Fenestration air leakageBAKHTIAR SHAMLOOenergy_progress
08/28/2022Permanent certificateBAKHTIAR SHAMLOOenergy_progress
08/28/2022Duct leakage testing, insulation and designBAKHTIAR SHAMLOOenergy_progress
08/28/2022Fenestration and door U-factor and product ratingsBAKHTIAR SHAMLOOenergy_progress
08/28/2022HVAC-R and service water heating equipmentBAKHTIAR SHAMLOOenergy_progress
08/28/2022Maintenance informationBAKHTIAR SHAMLOOenergy_progress
08/28/2022Interior lighting powerBAKHTIAR SHAMLOOenergy_progress
08/28/2022Air barrier — testing BAKHTIAR SHAMLOOenergy_progress
08/28/2022HVAC-R and service water piping design and insulationBAKHTIAR SHAMLOOenergy_progress
08/28/2022Fenestration areasBAKHTIAR SHAMLOOenergy_progress
08/28/2022Electric vehicle service equipment requirementsBAKHTIAR SHAMLOOenergy_progress
Latest 25 of 55.
81 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account