← Back
Miscellaneous one family
192 CONSELYEA STREET
BROOKLYN · BIN 3068757
💬 Discuss this project
1910Year Built
2Stories
A9Building Class
R6BZoning
2,114 sfGross Floor Area
1Units
Miscellaneous one family · 1,650 sf lot · 1.28 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof1p · 1 filing · 10 docs
Floor 24p · 2 filings · 16 docs
Floor 14p · 2 filings · 16 docs
Cellar3p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/31/2023$1.4M—Private party → Private party$662/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
F360 ARCHITECTURE PLLC310/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
UP DESIGN SERVICES303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LIBERTY GENERAL CONTRACTINGGeneral Contractor303/21/2026
JOSEPH WEINSTEIN ELECTRICElectrical103/22/2026
ARCO PLBG AND HTG INCPlumbing107/08/2026
TOP DOG PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SYED ENGINEERING, P.C.7054106/06/2023
Building Lifecycle
All (37)Filed (3)Permit Issued (3)Signed Off (1)Inspection (5)Objection (18)Special Inspection (7)
03/13/2025
Signed off — Alteration
removal, relocation and installation of new plumbing fixtures throughout
B00877246-I1
11/27/2024
Objection resolved — Addressed
11/20/2024
Objection resolved — Addressed
10/23/2024
Objection raised — Scope
10/17/2024
Objection raised — Scope
10/08/2024
Filed — Alteration
removal, relocation and installation of new plumbing fixtures throughout
B00877246-P1
05/01/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/27/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/13/2024
Permit issued — Plumbing
B00877246-I1-PL
02/23/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/15/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/15/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/27/2023
Permit issued — Plumbing
B00877246-I1-PL
07/12/2023
Permit issued — General Construction
B00877238-I1-GC
06/29/2023
Objection resolved — Addressed
06/29/2023
Objection resolved — Addressed
06/29/2023
Objection resolved — Addressed
06/28/2023
Objection raised — Inspections
06/28/2023
Objection raised — Inspections
06/28/2023
Objection resolved — Addressed
06/22/2023
Objection resolved — Addressed
06/22/2023
Objection resolved — Addressed
06/22/2023
Objection resolved — Addressed
06/14/2023
Objection raised — Energy
06/14/2023
Objection raised — Scope
06/14/2023
Objection raised — Other
06/12/2023
Objection raised — Scope
06/09/2023
Objection raised — Scope
06/06/2023
Filed — Alteration
removal, relocation and installation of new plumbing fixtures throughout
B00877246-I1
06/06/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING ONE FAMILY DWELLING, NO CHANGE IN USE , EGRESS OR OCCUPANCY
B00877238-I1
05/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAFI HAMID
05/30/2023
Special inspection requirement — Energy Code Compliance Inspections
RAFI HAMID
05/30/2023
Special inspection requirement — Fire-Resistance Rated Construction
RAFI HAMID
05/30/2023
Special inspection requirement — Lighting controls
RAFI HAMID
05/30/2023
Special inspection requirement — Fenestration areas
RAFI HAMID
05/30/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
RAFI HAMID
05/30/2023
Special inspection requirement — Fenestration air leakage
RAFI HAMID
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offARCO PLBG AND HTG INC03/13/2024
DOB NOWPlumbingSigned-offTOP DOG PLBG & HTG CORP07/27/2023
DOB NOWGeneral ConstructionPermit IssuedLIBERTY GENERAL CONTRACTI07/12/2023
2 projects · most recent 09/27/2023
General Wiring
FiledStatusContractorScope
09/27/2023CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
06/21/2023CompleteJOSEPH WEINSTEIN ELECTRIC1 meters
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
05/01/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/27/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/23/2024Fail-Final General Construction Non-Directive 14FailView ↗
09/15/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/15/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
05/30/2023Fire-Resistant Penetrations and JointsRAFI HAMIDspecial
05/30/2023Energy Code Compliance InspectionsRAFI HAMIDprogress
05/30/2023Fire-Resistance Rated ConstructionRAFI HAMIDprogress
05/30/2023Lighting controlsRAFI HAMIDenergy_progress
05/30/2023Fenestration areasRAFI HAMIDenergy_progress
05/30/2023Fenestration and door U-factor and product ratingsRAFI HAMIDenergy_progress
05/30/2023Fenestration air leakageRAFI HAMIDenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/27/2026B00877238-I1Request digital key ↗
08/14/2026B00877246-I1Request digital key ↗
08/14/2026B00877246-P1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature6
08/26/2026B00877238-I1Open ↗
08/26/2026B00877238-I1Open ↗
08/26/2026B00877238-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026B00877246-I1Open ↗
08/13/2026B00877246-P1Open ↗
08/13/2026B00877238-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B00877238-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/14/2026B00877246-I1Open ↗
08/13/2026B00877246-P1Open ↗
08/13/2026B00877238-I1Open ↗