← Back
Two family frame
1936 HUNT AVENUE
BRONX · BIN 2093230
💬 Discuss this project
1905Year Built
2Stories
B2Building Class
R5Zoning
1,854 sfGross Floor Area
2Units
7 Open Violations ▸FDNY Report ↗
Two family frame · 2,355 sf lot · 0.79 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PHANTOM CAPITAL BUILDINGS LLC303/22/2026
____S V DEVELOPEMENT603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RAMA TECH108/13/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KIRSCHENBAUM ARRIAGA203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRIME PIPING & HEATING INPlumbing407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CARUSONE & CHERRES ARCHIT6166108/13/2019
Building Lifecycle
All (37)Filed (1)Permit Issued (1)Signed Off (1)Violation (24)Inspection (5)Objection (2)Special Inspection (3)
06/05/2025
Violation issued (HPD, closed)
A
04/02/2024
Violation issued (HPD, closed)
A
06/09/2023
Signed off — Alteration
X00207214-I1
06/05/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/27/2023
Violation issued (ECB, open)
Construction
03/17/2023
Violation issued (HPD, closed)
A
11/03/2022
Violation issued (HPD, closed)
I
06/22/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/21/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/23/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/18/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/17/2022
Violation issued (HPD, closed)
I
02/17/2022
Violation issued (HPD, closed)
A
09/17/2021
Permit issued — Plumbing
X00207214-I1-PL
04/02/2021
Violation issued (HPD, closed)
A
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/03/2020
Violation issued (ECB, closed)
Boilers
03/03/2020
Violation issued (ECB, closed)
Boilers
10/28/2019
Violation issued (HPD, closed)
I
09/13/2019
Objection raised — Other
09/13/2019
Objection resolved — Addressed
08/13/2019
Filed — Alteration
X00207214-I1
08/08/2019
Special inspection requirement — Fire-Resistant Penetrations and Joints
JORGE CHERRES
08/08/2019
Special inspection requirement — Energy Code Compliance Inspections
RAJESH SHAH
08/08/2019
Special inspection requirement — Fire-Resistance Rated Construction
RAJESH SHAH
11/13/2017
Violation issued (HPD, closed)
I
10/31/2016
Violation issued (HPD, closed)
I
02/19/2016
Violation issued (HPD, open)
B
02/19/2016
Violation issued (HPD, closed)
C
02/19/2016
Violation issued (HPD, open)
C
02/19/2016
Violation issued (HPD, open)
B
02/19/2016
Violation issued (HPD, open)
B
10/05/2015
Violation issued (HPD, closed)
I
02/04/2015
Violation issued (HPD, closed)
I
01/06/2012
Violation issued (ECB, closed)
Construction
10/20/2006
Violation issued (HPD, open)
B
10/20/2006
Violation issued (HPD, open)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN09/17/2021
BISPLISSUEDFINEST MECHANICAL CORP05/15/2009
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/05/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/22/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/21/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/23/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/18/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
08/08/2019Fire-Resistant Penetrations and JointsJORGE CHERRESspecial
08/08/2019Energy Code Compliance InspectionsRAJESH SHAHprogress
08/08/2019Fire-Resistance Rated ConstructionRAJESH SHAHprogress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch - Plumbing Legalization1
08/14/2026X00207214-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
03/28/2023200946682Open ↗
09/14/2012220229394Open ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
08/22/2026X00207214-I1Open ↗
08/22/2026X00207214-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/14/2012220229394Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/26/2026X00207214-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026X00207214-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
09/14/2012220229394Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/14/2012220229394Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/14/2026X00207214-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/14/2012220229394Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
09/14/2012220229394Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/14/2012220229394Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/14/2012220229394Open ↗