← Back
Two stories - detached, small or mid-size
1955 TOMLINSON AVENUE
BRONX · Morris Park · BIN 2093274
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R4AZoning
2,596 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,500 sf lot · 1.04 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 25p · 2 filings · 14 docs
Floor 16p · 2 filings · 14 docs
Cellar9p · 2 filings · 14 docs
Site & exterior1p · 2 filings · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ALPHA HOME DESIGN103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/25/2023$775K—Private party → Private party$299/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASSIRI711/21/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KLE CONSTRUCTION INCGeneral Contractor207/08/2026
KJK ELECTRIC INCElectrical103/22/2026
CATMAN PLUMBING INCPlumbing107/08/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394208/28/2023
Building Lifecycle
All (29)Filed (7)Permit Issued (4)Signed Off (4)Violation (1)Inspection (7)Special Inspection (6)
04/15/2024
Signed off — Alteration
RESOLVE ECB VIOLATION: 39099788K; TO REMOVE ILLEGAL REAR YARD CEMENT BLOCK WALL ENCLOSURE AND PLUMBING PIPES FOR THE YARD DRAIN, RESTORE TO PRIOR LEGAL CONDITION. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THISA PPLICATION.
X00965861-I1
04/03/2024
Signed off — Alteration
RESOLVE ECB VIOLATION: 39099788K; TO REMOVE ILLEGAL REAR YARD CEMENT BLOCK WALL ENCLOSURE AND PLUMBING PIPES FOR THE YARD DRAIN, RESTORE TO PRIOR LEGAL CONDITION. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00965854-I1
04/02/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/11/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
12/26/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/19/2023
Permit issued — Plumbing
X00965861-I1-PL
12/06/2023
Permit issued — General Construction
X00965854-I1-GC
11/21/2023
Filed — Alteration
RESOLVE ECB VIOLATION: 39099788K; TO REMOVE ILLEGAL REAR YARD CEMENT BLOCK WALL ENCLOSURE AND PLUMBING PIPES FOR THE YARD DRAIN, RESTORE TO PRIOR LEGAL CONDITION. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THISA PPLICATION.
X00965861-I1
11/21/2023
Filed — Alteration
RESOLVE ECB VIOLATION: 39099788K; TO REMOVE ILLEGAL REAR YARD CEMENT BLOCK WALL ENCLOSURE AND PLUMBING PIPES FOR THE YARD DRAIN, RESTORE TO PRIOR LEGAL CONDITION. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00965854-I1
11/20/2023
Violation issued (ECB, closed)
Construction
10/31/2023
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00868706-I1
10/31/2023
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00868711-I1
09/12/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/05/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
08/28/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00868706-P1
08/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
08/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
08/28/2023
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
08/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
08/28/2023
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
08/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
08/14/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00868711-P2
06/26/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00868711-P1
06/23/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/23/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/12/2023
Permit issued — General Construction
X00868706-I1-GC
05/12/2023
Permit issued — Plumbing
X00868711-I1-PL
05/09/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00868706-I1
05/09/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00868711-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG12/19/2023
DOB NOWGeneral ConstructionSigned-offKLE CONSTRUCTION INC12/06/2023
DOB NOWGeneral ConstructionSigned-offKLE CONSTRUCTION INC05/12/2023
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC05/12/2023
2 projects · most recent 12/20/2023
General Wiring
FiledStatusContractorScope
12/20/2023Permit IssuedKJK ELECTRIC INCGeneral Wiring
09/06/2023CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/02/2024Pass-Final General Construction Non-Directive 14PassView ↗
03/11/2024Fail-Final General Construction Non-Directive 14FailView ↗
12/26/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/12/2023Pass-Final General Construction Non-Directive 14PassView ↗
09/05/2023Fail-Final General Construction Non-Directive 14FailView ↗
06/23/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/23/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
08/28/2023Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
08/28/2023Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
08/28/2023Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
08/28/2023Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
08/28/2023Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
08/28/2023Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/23/2026X00868711-P1Request digital key ↗
08/23/2026X00868711-I1Request digital key ↗
08/23/2026X00868711-P2Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/23/2026X00868711-P1Open ↗
08/23/2026X00868711-I1Open ↗
08/23/2026X00868711-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
10/01/2026X00868706-P1Open ↗
08/22/2026X00868706-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
10/01/2026X00868706-P1Open ↗
08/22/2026X00868706-I1Open ↗