← Back
Walk-up cooperative
Meadowlark Gardens
196-14 69 AVENUE · Fresh Meadows-Utopia · BIN 4459743
💬 Discuss this project
1951Year Built
2Stories
C6Building Class
R4Zoning
116,000 sfGross Floor Area
148Units
LL97 CoveredRent Stabilized17 Open Violations ▸
Walk-up cooperative · Owner of record: MEADOWLARK GARDENS OWNERS INC · 225,750 sf lot · 0.51 FAR built · Flood zone X
Locations of Work
Mechanical
Permit Issued — active, not yet Signed-off
Floor 2Under Construction4p · 1 filing · 20 docs
Floor 1Under Construction4p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZARO ENGINEERING PC208/18/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
OUTSOURCE CONSULTANTS, INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
THE SCI CONSTRUCTIONGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
OUTSOURCE SPECIAL INSPECT2827208/18/2026
Building Lifecycle
All (23)Filed (2)Permit Issued (1)Special Inspection (20)
08/21/2026
Special inspection requirement — Tenant Protection Plan Compliance
JONAR MADRIAGA
08/21/2026
Special inspection requirement — Mechanical Systems
JONAR MADRIAGA
08/21/2026
Special inspection requirement — Heating Systems
JONAR MADRIAGA
08/21/2026
Special inspection requirement — Energy Code Compliance Inspections
JONAR MADRIAGA
08/21/2026
Special inspection requirement — Final
JONAR MADRIAGA
08/21/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
JONAR MADRIAGA
08/21/2026
Special inspection requirement — HVAC-R and service water heating system controls
JONAR MADRIAGA
08/21/2026
Special inspection requirement — HVAC-R and service water heating equipment
JONAR MADRIAGA
08/21/2026
Special inspection requirement — Ventilation and air distribution system
JONAR MADRIAGA
08/21/2026
Special inspection requirement — Maintenance information
JONAR MADRIAGA
08/18/2026
Filed — Alteration
INSTALLATION OF DUCTLESS MINI SPLIT SYSTEM FOR HEATING AND COOLING AS PER PLANS FILED HEREWITH . NO CHANGE IN USE EGRESS OR OCCUPANCY
Q01364390-P1
07/23/2026
Special inspection requirement — Heating Systems
JONAR MADRIAGA
07/23/2026
Special inspection requirement — Mechanical Systems
JONAR MADRIAGA
07/23/2026
Special inspection requirement — Tenant Protection Plan Compliance
JONAR MADRIAGA
07/23/2026
Special inspection requirement — Energy Code Compliance Inspections
JONAR MADRIAGA
07/23/2026
Special inspection requirement — Final
JONAR MADRIAGA
07/23/2026
Special inspection requirement — Maintenance information
JONAR MADRIAGA
07/23/2026
Special inspection requirement — Ventilation and air distribution system
JONAR MADRIAGA
07/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
JONAR MADRIAGA
07/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
JONAR MADRIAGA
07/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
JONAR MADRIAGA
03/20/2026
Permit issued — Mechanical Systems
Q01364390-I1-MS
03/02/2026
Filed — Alteration
INSTALLATION OF DUCTLESS MINI SPLIT SYSTEM FOR HEATING AND COOLING AS PER PLANS FILED HEREWITH . NO CHANGE IN USE EGRESS OR OCCUPANCY
Q01364390-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedTHE SCI CONSTRUCTION03/20/2026
1 project · most recent 08/18/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/18/2026Permit IssuedTHE SCI CONSTRUCTIONHeating and Air Conditioning Systems
Heat / Cool
Midea MO3HX-H18B-2A 20,000 BTU · Condensing Unit ×4
MSEHU-H12B-2A 12,000 BTU · Fan Coil Indoor ×4
MSEHU-HO6B-2A 6,000 BTU · Fan Coil Indoor ×4
3 projects · most recent 03/24/2026
HVAC Wiring General Wiring
FiledStatusContractorScope
03/24/2026Permit IssuedDVM ELECTRICAL SERVICES LHVAC Wiring
12/08/2023Permit IssuedDVM ELECTRICAL SERVICES L2 meters, 1 new_meters
05/16/2023Permit IssuedDVM ELECTRICAL SERVICES LGeneral Wiring
1 project · most recent 08/18/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
08/18/2026Permit IssuedTHE SCI CONSTRUCTIONTenant Protection Plan 72 Hour
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
08/21/2026Tenant Protection Plan ComplianceJONAR MADRIAGAspecial
08/21/2026Mechanical SystemsJONAR MADRIAGAspecial
08/21/2026Heating SystemsJONAR MADRIAGAspecial
08/21/2026Energy Code Compliance InspectionsJONAR MADRIAGAprogress
08/21/2026FinalJONAR MADRIAGAprogress
08/21/2026HVAC-R and service water piping design and insulationJONAR MADRIAGAenergy_progress
08/21/2026HVAC-R and service water heating system controlsJONAR MADRIAGAenergy_progress
08/21/2026HVAC-R and service water heating equipmentJONAR MADRIAGAenergy_progress
08/21/2026Ventilation and air distribution systemJONAR MADRIAGAenergy_progress
08/21/2026Maintenance informationJONAR MADRIAGAenergy_progress
07/23/2026Heating SystemsJONAR MADRIAGAspecial
07/23/2026Mechanical SystemsJONAR MADRIAGAspecial
07/23/2026Tenant Protection Plan ComplianceJONAR MADRIAGAspecial
07/23/2026Energy Code Compliance InspectionsJONAR MADRIAGAprogress
07/23/2026FinalJONAR MADRIAGAprogress
07/23/2026Maintenance informationJONAR MADRIAGAenergy_progress
07/23/2026Ventilation and air distribution systemJONAR MADRIAGAenergy_progress
07/23/2026HVAC-R and service water piping design and insulationJONAR MADRIAGAenergy_progress
07/23/2026HVAC-R and service water heating equipmentJONAR MADRIAGAenergy_progress
07/23/2026HVAC-R and service water heating system controlsJONAR MADRIAGAenergy_progress
▾Documents — 24 on file (BIS + DOB NOW)
▸Seals & Professional Certifications22
▸DOB NOWProgress Inspector Seal & Signature14
09/23/2026Q01364390-I1Open ↗
09/23/2026Q01364390-I1Open ↗
09/23/2026Q01364390-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026Q01364390-I1Open ↗
09/23/2026Q01364390-I1Open ↗
09/23/2026Q01364390-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/19/2026Q01364390-P1Open ↗
08/13/2026Q01364390-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026Q01364390-P1Open ↗
08/13/2026Q01364390-I1Open ↗