← Back
Two family brick
196 GREENE AVENUE
BROOKLYN · Clinton Hill · BIN 3056141
💬 Discuss this project
1870Year Built
3Stories
B1Building Class
R6BZoning
3,600 sfGross Floor Area
2Units
Two family brick · 1,500 sf lot · 2.4 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof12p · 3 filings · 20 docs
Floor 318p · 3 filings · 20 docs
Floor 220p · 3 filings · 20 docs
Floor 120p · 4 filings · 20 docs
Cellar20p · 3 filings · 20 docs
Sub-Basement18p · 3 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/12/2021$2.9M—Private party → Private party$799/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
D'ANTONIO CONSULTING ENGINEERS206/27/2022
DAMERON ARCHITECTURE PLLC206/24/2022
SILMAN106/15/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J CALLAHAN CONSULTING1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROSE & STONE CONSTRUCTIONGeneral Contractor507/08/2026
EBONY & IVORY P & H CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D'ANTONIO CONSULTING ENGI931206/27/2022
DAMERON ARCHITECTURE PLLC6516206/24/2022
ASE ENGINEERING PLLC5785206/15/2022
Building Lifecycle
All (31)Filed (5)Permit Issued (5)Inspection (5)Objection (4)Special Inspection (12)
02/28/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/03/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/03/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/05/2023
Permit issued — Structural
B00733182-I1-ST
04/05/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/04/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/02/2022
Permit issued — Plumbing
B00733210-I1-PL
07/15/2022
Permit issued — Mechanical Systems
B00733081-I1-MS
07/11/2022
Objection raised — Scope
07/11/2022
Objection resolved — Addressed
07/11/2022
Objection raised — Fire_Protection
07/11/2022
Objection resolved — Addressed
07/05/2022
Permit issued — Structural
B00733182-I1-ST
07/05/2022
Permit issued — General Construction
B00725128-I1-GC
06/27/2022
Filed — Alteration
Install new heat pump air conditioning and ventilation system throughout existing townhouse. No change to use, egress or occupancy.
B00733081-I1
06/27/2022
Filed — Alteration
Plumbing work associated with renovation of existing townhouse throughout. No change to use, egress or occupancy.
B00733210-I1
06/24/2022
Filed — Alteration
Renovation of an existing single family townhouse throughout. New rear deck and exterior stair from deck to rear yard. No change to use. egress or occupancy.
B00725128-P1
06/24/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
alon egozi
06/24/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Christopher dameron
06/24/2022
Special inspection requirement — Fire-Resistance Rated Construction
John Christopher dameron
06/24/2022
Special inspection requirement — Energy Code Compliance Inspections
John Christopher dameron
06/24/2022
Special inspection requirement — Final
John Christopher dameron
06/24/2022
Special inspection requirement — Interior lighting power
John Christopher dameron
06/24/2022
Special inspection requirement — Lighting controls
John Christopher dameron
06/24/2022
Special inspection requirement — Lighting in dwelling units
John Christopher dameron
06/24/2022
Special inspection requirement — Fenestration air leakage
John Christopher dameron
06/24/2022
Special inspection requirement — Insulation placement and R values
John Christopher dameron
06/24/2022
Special inspection requirement — Fenestration areas
John Christopher dameron
06/24/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
John Christopher dameron
06/15/2022
Filed — Alteration
Renovation of an existing single family townhouse throughout. New rear deck and exterior stair from deck to rear yard. No change to use. egress or occupancy.
B00725128-I1
06/15/2022
Filed — Alteration
Structural work for new rear deck, lintel and dunnage on roof. No change to use, egress or occupancy.
B00733182-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedROSE & STONE CONSTRUCTION06/05/2023
DOB NOWPlumbingPermit IssuedEBONY & IVORY P & H CORP08/02/2022
DOB NOWMechanical SystemsPermit IssuedROSE & STONE CONSTRUCTION07/15/2022
DOB NOWStructuralPermit IssuedROSE & STONE CONSTRUCTION07/05/2022
DOB NOWGeneral ConstructionPermit IssuedROSE & STONE CONSTRUCTION07/05/2022
1 project · most recent 06/27/2022
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/27/2022Permit IssuedROSE & STONE CONSTRUCTIONHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUMY-HP48NKMU1 48,000 BTU · Vrf Outdoor ×2
Ventilation
Panasonic FV-11VQ5 75 CFM · Exhaust Fan ×3
1 project · most recent 06/27/2022
Gas Water/Sanitary
FiledStatusContractorScope
06/27/2022Permit IssuedEBONY & IVORY P & H CORPGas, Water/Sanitary
1 project · most recent 05/27/2022
General Wiring
FiledStatusContractorScope
05/27/2022Permit IssuedFRITZMARTIN ELECTRIC INC.General Wiring
1 project · most recent 06/15/2022
Steel
FiledStatusContractorScope
06/15/2022Permit IssuedROSE & STONE CONSTRUCTIONSteel
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/28/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/03/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/03/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/05/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/04/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
06/24/2022Structural Stability – Alterations of existing buildingsalon egozispecial
06/24/2022Fire-Resistant Penetrations and JointsJohn Christopher dameronspecial
06/24/2022Fire-Resistance Rated ConstructionJohn Christopher dameronprogress
06/24/2022Energy Code Compliance InspectionsJohn Christopher dameronprogress
06/24/2022FinalJohn Christopher dameronprogress
06/24/2022Interior lighting powerJohn Christopher dameronenergy_progress
06/24/2022Lighting controlsJohn Christopher dameronenergy_progress
06/24/2022Lighting in dwelling unitsJohn Christopher dameronenergy_progress
06/24/2022Fenestration air leakageJohn Christopher dameronenergy_progress
06/24/2022Insulation placement and R valuesJohn Christopher dameronenergy_progress
06/24/2022Fenestration areasJohn Christopher dameronenergy_progress
06/24/2022Fenestration and door U-factor and product ratingsJohn Christopher dameronenergy_progress
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/29/2026B00733182-I1Request digital key ↗
08/29/2026B00725128-I1Request digital key ↗
08/29/2026B00725128-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/13/2026B00725128-P1Open ↗
08/13/2026B00725128-I1Open ↗
08/13/2026B00733182-I1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature10
08/22/2026B00725128-I1Open ↗
08/22/2026B00725128-I1Open ↗
08/22/2026B00725128-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/29/2026B00725128-I1Open ↗
08/29/2026B00725128-P1Open ↗
08/13/2026B00733210-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026B00725128-I1Open ↗
08/22/2026B00725128-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/29/2026B00725128-P1Open ↗
08/29/2026B00725128-I1Open ↗
08/13/2026B00733210-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00733210-I1Open ↗