← Back
BuildNYC
One family attached or semi-detached
196 MIDWOOD STREET
BROOKLYN · BIN 3115171
💬 Discuss this project
1910Year Built
2Stories
A5Building Class
R2Zoning
1,800 sfGross Floor Area
1Units
One family attached or semi-detached · 2,000 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 6 docs
Floor 2Rutland Two-story + basement building demolitionUnder Construction17p · 4 filings · 20 docs
Floor 1Rutland Two-story + basement building demolitionUnder Construction17p · 4 filings · 20 docs
CellarUnder Construction17p · 2 filings · 17 docs
BasementRutland Two-story + basement building demolitionUnder Construction2p · 2 filings · 15 docs
Sub-BasementRutland Two-story + basement building demolitionUnder Construction1p · 2 filings · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/03/2025$2.3M—Private party → Private party$1,267/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Raad310/16/2026
Overhead Architecture203/02/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB Building Consulting403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BZJ ConstructionGeneral Contractor204/09/2026
BZJ Constructionspecialty_contractor104/09/2026
Crown PlumbingPlumbing110/09/2026
Jada Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Raad7727410/16/2026
Building Lifecycle
10/16/2026
Filed — Alteration
INSTALLATION OF PLUMBING FIXTURES
B01295443-P1
10/15/2026
Special inspection requirement — HVAC-R and service water heating system controls
NICHOLAS AZADIAN
10/15/2026
Special inspection requirement — HVAC-R and service water heating equipment
NICHOLAS AZADIAN
10/15/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
NICHOLAS AZADIAN
10/15/2026
Special inspection requirement — Energy Code Compliance Inspections
NICHOLAS AZADIAN
46 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCrown Plumbing10/07/2026
DOB NOWGeneral ConstructionPermit IssuedBZJ Construction03/25/2026
DOB NOWMechanical SystemsPermit IssuedBZJ Construction03/24/2026
DOB NOWGeneral ConstructionSigned-offBZJ Construction03/05/2026
DOB NOWPlumbingPermit IssuedJada Plumbing & Heating03/04/2026
1 project · most recent 01/09/2026
Heating and Air Conditioning Systems Heating Systems
FiledStatusContractorScope
01/09/2026Permit IssuedBZJ ConstructionHeating and Air Conditioning Systems, Heating Systems
1 project · most recent 10/16/2026
Gas Water/Sanitary
FiledStatusContractorScope
10/16/2026Permit IssuedCrown PlumbingGas, Water/Sanitary
2 projects · most recent 10/12/2026
General Wiring
FiledStatusContractorScope
10/12/2026Permit IssuedSuper Charged ElectricGeneral Wiring
12/22/2023CompleteSterling Electric—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/29/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/29/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/29/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
10/15/2026HVAC-R and service water heating system controlsNICHOLAS AZADIANenergy_progress
10/15/2026HVAC-R and service water heating equipmentNICHOLAS AZADIANenergy_progress
10/15/2026HVAC-R and service water piping design and insulationNICHOLAS AZADIANenergy_progress
10/15/2026Energy Code Compliance InspectionsNICHOLAS AZADIANprogress
10/15/2026Fire-Resistant Penetrations and JointsNICHOLAS AZADIANspecial
02/26/2026FinalMatthew Ransomprogress
12/16/2025HVAC-R and service water heating equipmentNICHOLAS AZADIANenergy_progress
12/16/2025Fire-Resistant Penetrations and JointsNICHOLAS AZADIANspecial
12/16/2025Energy Code Compliance InspectionsNICHOLAS AZADIANprogress
12/16/2025HVAC-R and service water heating equipmentNICHOLAS AZADIANenergy_progress
12/16/2025HVAC-R and service water heating system controlsNICHOLAS AZADIANenergy_progress
12/16/2025HVAC-R and service water piping design and insulationNICHOLAS AZADIANenergy_progress
12/16/2025Shutoff dampersNICHOLAS AZADIANenergy_progress
12/16/2025Fire-Resistant Penetrations and JointsNICHOLAS AZADIANspecial
12/16/2025Energy Code Compliance InspectionsNICHOLAS AZADIANprogress
12/16/2025Duct leakage testing, insulation and designNICHOLAS AZADIANenergy_progress
12/16/2025HVAC-R and service water heating system controlsNICHOLAS AZADIANenergy_progress
12/16/2025HVAC-R and service water piping design and insulationNICHOLAS AZADIANenergy_progress
09/30/2025FinalNICHOLAS AZADIANprogress
09/30/2025Mechanical SystemsNICHOLAS AZADIANspecial
08/26/2025Fire-Resistant Penetrations and JointsNICHOLAS AZADIANspecial
08/26/2025FinalMatthew Ransomprogress
08/26/2025Fire-Resistance Rated ConstructionMatthew Ransomprogress
33 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account