← Back
Three families
1968 ELLIS AVENUE
BRONX · BIN 2025875
💬 Discuss this project
1930Year Built
2Stories
C0Building Class
R5Zoning
2,836 sfGross Floor Area
3Units
Rent Stabilized7 Open Violations ▸
Three families · 2,506 sf lot · 1.13 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 2 filings · 4 docs
Floor 1
Basement2p · 2 filings · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/22/2023$1.1M—— → —$388/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
H G LEE ARCHITECT PC210/27/2025
THOMAS J. CURRO ARCHITECT, PC107/29/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOHN FITZGERALD PLBG &HTGPlumbing203/22/2026
JOEL GUZMANElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HG LEE ARCHITECT PC2554210/27/2025
THOMAS J. CURRO ARCHITECT718107/29/2023
Building Lifecycle
All (29)Filed (3)Violation (20)Objection (4)Special Inspection (2)
04/30/2026
Violation issued (HPD, open)
A
12/15/2025
Objection raised — Scope
12/15/2025
Objection resolved — Addressed
11/18/2025
Violation issued (HPD, open)
I
11/10/2025
Objection raised — Admin
11/10/2025
Objection resolved — Addressed
10/27/2025
Filed — Alteration
No change in use of egress, occupancy and bulk. Resolve violation #39149485X. Replace with a new garage door and remove metal and wood tracking studs; Resolve violation #39149486H replace door with new window.
X01273441-I1
08/01/2025
Filed — Alteration
X01261864-I1
06/05/2025
Violation issued (HPD, open)
A
05/30/2025
Violation issued (ECB, open)
Construction
05/30/2025
Violation issued (ECB, open)
Unknown
05/30/2025
Violation issued (ECB, open)
Construction
04/02/2024
Violation issued (HPD, closed)
A
03/09/2024
Violation issued (ECB, open)
Unknown
07/29/2023
Filed — Alteration
ALTERATIONS TO REPAIR FIRE DAMAGED FLOOR JOISTS, PARTITIONS, AND FINISHES AT BASEMENT AND 1ST FLOOR. NO CHANGE IN USE, EGRESS OR OCCPANCY.
X00898296-I1
06/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
THOMAS CURRO
06/30/2023
Special inspection requirement — Final
THOMAS CURRO
03/17/2023
Violation issued (HPD, closed)
A
11/04/2022
Violation issued (HPD, closed)
I
02/17/2022
Violation issued (HPD, closed)
A
02/17/2022
Violation issued (HPD, closed)
I
04/02/2021
Violation issued (HPD, closed)
I
04/02/2021
Violation issued (HPD, closed)
A
10/28/2019
Violation issued (HPD, closed)
I
10/11/2018
Violation issued (HPD, closed)
I
11/13/2017
Violation issued (HPD, closed)
I
10/28/2016
Violation issued (HPD, closed)
I
10/05/2015
Violation issued (HPD, closed)
I
02/04/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDVOLTAIC SOLAIRE LLC11/08/2023
BISOTISSUEDSENSIBLE CHOICE CONTRACT02/15/2017
3 projects · most recent 08/09/2024
General Wiring
FiledStatusContractorScope
08/09/2024CompleteTWINS ELECTRIC OF NY INCGeneral Wiring
04/18/2024Permit IssuedENTERPRISE ELEC'L SYSTEMS3 meters
10/19/2023CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
06/30/2023Fire-Resistant Penetrations and JointsTHOMAS CURROspecial
06/30/2023FinalTHOMAS CURROprogress
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026X00898296-I1Request digital key ↗
08/18/2026X01261864-I1Request digital key ↗
08/18/2026X01273441-I1Request digital key ↗
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION5
10/31/2023240357369Open ↗
07/13/2023220579924Open ↗
06/30/2023220579924Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION2
11/08/2023240357369Open ↗
02/17/2017220579924Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/22/2026X00898296-I1Open ↗
08/18/2026X01261864-I1Open ↗
08/13/2026X01273441-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/31/2023240357369Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/01/2023240357369Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/26/2017220579924Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/31/2026X00898296-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026X00898296-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
01/26/2017220579924Open ↗
▸Safety & Tenant Protection2
▸BISTPP1: TENANT PROTECTION PLAN1
11/01/2023240357369Open ↗
▸BISTenant Protection Plan and Notes1
01/26/2017220579924Open ↗
▸Environmental & Asbestos3
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/31/2023240357369Open ↗
02/14/2017220579924Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/22/2026X00898296-I1Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/31/2023240357369Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
10/31/2023240357369Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/26/2017220579924Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/31/2023240357369Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
11/01/2023240357369Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
10/31/2023240357369Open ↗
01/26/2017220579924Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION1
06/30/2023220579924Open ↗
▸BISEFILING COVER SHEET1
01/26/2017220579924Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/31/2023240357369Open ↗