← Back
Unlicensed parking lot
1971 HONEYWELL AVENUE
BRONX · West Farms · BIN 2130778
💬 Discuss this project
0Year Built
—Stories
G7Building Class
R7-1Zoning
0 sfGross Floor Area
0Units
1 Open Violation ▸FDNY Report ↗
Unlicensed parking lot · Owner of record: GS HONEYWELL BX LLC · 1,735 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralCivilGeneral
Permit Issued — active, not yet Signed-off
Floor 216p · 1 filing · 20 docs
Floor 117p · 1 filing · 20 docs
Cellar16p · 1 filing · 20 docs
Site & exteriorUnder Construction2p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BROOKLYN GRID1104/09/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAYSIDE ENGINEERING PC508/13/2024
JUST CONSULTING ENGINEERING109/21/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WM ARCH403/21/2026
NEXT STEP BUILDING SOLUTIONS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LLNY GROUP,LLCGeneral Contractor304/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010108/13/2024
Building Lifecycle
All (90)Filed (6)Permit Issued (3)Violation (1)Objection (62)Special Inspection (18)
03/11/2026
Permit issued — Construction Fence
X01049888-I1-FN
01/27/2026
Permit issued — Construction Fence
X01049888-I1-FN
11/18/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/24/2025
Permit issued — Construction Fence
X01049888-I1-FN
08/27/2024
Objection resolved — Addressed
08/27/2024
Objection resolved — Addressed
08/27/2024
Objection resolved — Addressed
08/27/2024
Objection resolved — Addressed
08/27/2024
Objection resolved — Addressed
08/27/2024
Objection resolved — Addressed
08/27/2024
Objection resolved — Addressed
08/19/2024
Objection raised — Other
08/15/2024
Objection raised — Structural
08/15/2024
Objection raised — Scope
08/15/2024
Objection raised — Structural
08/15/2024
Objection raised — Structural
08/15/2024
Objection raised — Fire_Protection
08/15/2024
Objection raised — Scope
08/15/2024
Objection raised — Admin
08/15/2024
Objection raised — Structural
08/15/2024
Objection raised — Admin
08/15/2024
Objection raised — Admin
08/13/2024
Filed — New Building
Proposed foundation work for 4 story new building.
X00750814-S7
08/13/2024
Filed — New Building
Proposed foundation work for 4 story new building.
X00750814-S5
08/13/2024
Filed — New Building
Proposed foundation work for 4 story new building.
X00750814-S6
08/09/2024
Special inspection requirement — Concrete - Cast-In-Place
08/09/2024
Special inspection requirement — Masonry
08/09/2024
Special inspection requirement — Subgrade Inspections
08/09/2024
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
08/09/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
05/24/2024
Objection resolved — Addressed
05/22/2024
Objection raised — Inspections
05/20/2024
Filed — Alteration
TEMPORARY CONSTRUCTION FENCE FOR 1971 HONEYWELL AVE. NO CHANGE TO USE. EGRESS, OCCUPANCY UNDER THIS APPLICATION.
X01049888-I1
12/21/2022
Objection raised — Mechanical
12/21/2022
Objection resolved — Addressed
09/22/2022
Objection raised — Admin
09/22/2022
Objection raised — Structural
09/21/2022
Filed — New Building
Proposed foundation work for 4 story new building.
X00750814-S2
09/19/2022
Special inspection requirement — Structural Steel - Details
09/19/2022
Special inspection requirement — Structural Steel - High Strength Bolting
09/19/2022
Special inspection requirement — Structural Steel - Welding
09/19/2022
Special inspection requirement — Subgrade Inspections
09/19/2022
Special inspection requirement — Concrete - Cast-In-Place
09/19/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
TONY ONYEAGORO
09/19/2022
Special inspection requirement — Final
09/19/2022
Special inspection requirement — Footing and Foundation
09/19/2022
Special inspection requirement — Deep Foundation Elements
09/19/2022
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
09/19/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/19/2022
Special inspection requirement — Masonry
09/19/2022
Special inspection requirement — Structural Cold-Formed Steel
09/17/2022
Objection raised — Fire_Protection
09/17/2022
Objection resolved — Addressed
09/17/2022
Objection raised — Accessibility
09/17/2022
Objection resolved — Addressed
09/17/2022
Objection raised — Zoning
09/17/2022
Objection resolved — Addressed
09/17/2022
Objection raised — Other
09/17/2022
Objection resolved — Addressed
09/17/2022
Objection raised — Energy
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedLLNY GROUP,LLC03/11/2026
DOB NOWConstruction FencePermit IssuedLLNY GROUP,LLC01/27/2026
DOB NOWConstruction FencePermit IssuedLLNY GROUP,LLC01/24/2025
1 project · most recent 08/13/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/13/2024——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-3C24NAHZ 24,000 BTU · Heat Pump Outdoor ×6
MXZ-4C36NAHZ 45,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 08/13/2024
Steel Concrete Masonry
FiledStatusContractorScope
08/13/2024——Steel, Concrete, Masonry
1 project · most recent 05/20/2024
Fence
FiledStatusContractorScope
05/20/2024Permit IssuedLLNY GROUP,LLCFence
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
08/09/2024Concrete - Cast-In-Place—special
08/09/2024Masonry—special
08/09/2024Subgrade Inspections—special
08/09/2024Subsurface Conditions – Fill Placement & In-Place Density—special
08/09/2024Subsurface Investigations (Borings/Test Pits)—special
09/19/2022Structural Steel - Details—special
09/19/2022Structural Steel - High Strength Bolting—special
09/19/2022Structural Steel - Welding—special
09/19/2022Subgrade Inspections—special
09/19/2022Concrete - Cast-In-Place—special
09/19/2022Subsurface Investigations (Borings/Test Pits)TONY ONYEAGOROspecial
09/19/2022Final—progress
09/19/2022Footing and Foundation—progress
09/19/2022Deep Foundation Elements—special
09/19/2022Excavations - Sheeting, Shoring, and Bracing—special
09/19/2022Fire-Resistant Penetrations and Joints—special
09/19/2022Masonry—special
09/19/2022Structural Cold-Formed Steel—special
▾Documents — 3 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026X01049888-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X01049888-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026X00750814-S2Open ↗