← Back
Two stories - detached, small or mid-size
198-18 27 AVENUE
QUEENS · BIN 4132870
💬 Discuss this project
1945Year Built
2.5Stories
A1Building Class
R2AZoning
2,558 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,795 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Floor 21p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
Cellar2p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/11/2023$800K—— → —$313/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC104/25/2024
MEI ARCHITECT PLLC204/05/2024
MEHDI GHAZI, P.E., P.C.401/04/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ALPHA HOME DESIGN LLC1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TLS CONSTRUCTION GROUP I*General Contractor507/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854104/25/2024
MEHDI GHAZI, P.E. P.C.7129504/05/2024
Building Lifecycle
All (61)Filed (7)Permit Issued (5)Signed Off (5)Inspection (4)Objection (10)Special Inspection (30)
06/21/2024
Signed off — Alteration CO
PROPOSE ENLARGEMENT FOR AN EXISTING 1-FAMILY DETACHED RESIDENCE. OBTAIN A NEW C OF O.
Q00847572-I1
06/10/2024
Signed off — Alteration CO
PROPOSE ENLARGEMENT FOR AN EXISTING 1-FAMILY DETACHED RESIDENCE. OBTAIN A NEW C OF O.
Q00847572-S2
05/31/2024
Signed off — Alteration CO
PROPOSE ENLARGEMENT FOR AN EXISTING 1-FAMILY DETACHED RESIDENCE. OBTAIN A NEW C OF O.
Q00847572-S1
05/29/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01041878-I1
05/15/2024
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00847470-I1
05/03/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/01/2024
Permit issued — Solar
Q01041878-I1-SL
04/25/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01041878-I1
04/25/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/25/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/25/2024
Special inspection requirement — Final
TOM PETERSEN
04/25/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/19/2024
Permit issued — Mechanical Systems
Q00847572-I1-GC-CX
04/16/2024
Special inspection requirement — Chimneys and vents
MEHDI GHAZI
04/16/2024
Special inspection requirement — Heating Systems
MEHDI GHAZI
04/16/2024
Special inspection requirement — Fire-Resistance Rated Construction
MEHDI GHAZI
04/16/2024
Special inspection requirement — Final
MEHDI GHAZI
04/16/2024
Special inspection requirement — Energy Code Compliance Inspections
MEHDI GHAZI
04/16/2024
Special inspection requirement — Permanent certificate
MEHDI GHAZI
04/16/2024
Special inspection requirement — Protection of exposed foundation insulation
MEHDI GHAZI
04/16/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
MEHDI GHAZI
04/16/2024
Special inspection requirement — Insulation placement and R values
MEHDI GHAZI
04/16/2024
Special inspection requirement — Air barrier - visual inspection
MEHDI GHAZI
04/16/2024
Special inspection requirement — Maintenance information
MEHDI GHAZI
04/16/2024
Special inspection requirement — HVAC-R and service water heating system controls
MEHDI GHAZI
04/16/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
MEHDI GHAZI
04/16/2024
Special inspection requirement — Fenestration areas
MEHDI GHAZI
04/16/2024
Special inspection requirement — Interior lighting power
MEHDI GHAZI
04/16/2024
Special inspection requirement — Fenestration air leakage
MEHDI GHAZI
04/16/2024
Special inspection requirement — HVAC-R and service water heating equipment
MEHDI GHAZI
04/16/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
04/16/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
04/16/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
MEHDI GHAZI
04/16/2024
Special inspection requirement — Mechanical Systems
MEHDI GHAZI
04/05/2024
Filed — Alteration CO
PROPOSE ENLARGEMENT FOR AN EXISTING 1-FAMILY DETACHED RESIDENCE. OBTAIN A NEW C OF O.
Q00847572-P2
04/05/2024
Special inspection requirement — Air barrier - visual inspection
MEHDI GHAZI
04/05/2024
Special inspection requirement — Chimneys and vents
MEHDI GHAZI
04/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
04/05/2024
Special inspection requirement — Heating Systems
MEHDI GHAZI
01/10/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/10/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/10/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/04/2024
Filed — Alteration CO
PROPOSE ENLARGEMENT FOR AN EXISTING 1-FAMILY DETACHED RESIDENCE. OBTAIN A NEW C OF O.
Q00847572-P1
07/17/2023
Permit issued — Plumbing
Q00847572-S2-PL
06/21/2023
Permit issued — General Construction
Q00847572-S1-GC-CX
06/13/2023
Permit issued — Construction Fence
Q00847470-I1-FN
06/07/2023
Filed — Alteration CO
PROPOSE ENLARGEMENT FOR AN EXISTING 1-FAMILY DETACHED RESIDENCE. OBTAIN A NEW C OF O.
Q00847572-S2
06/07/2023
Filed — Alteration CO
PROPOSE ENLARGEMENT FOR AN EXISTING 1-FAMILY DETACHED RESIDENCE. OBTAIN A NEW C OF O.
Q00847572-S1
05/19/2023
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00847470-I1
05/11/2023
Objection raised — Scope
05/11/2023
Objection resolved — Addressed
04/11/2023
Objection raised — Admin
04/11/2023
Objection resolved — Addressed
04/11/2023
Objection raised — Zoning
04/11/2023
Objection resolved — Addressed
04/11/2023
Objection raised — Scope
04/11/2023
Objection resolved — Addressed
04/11/2023
Objection raised — Admin
04/11/2023
Objection resolved — Addressed
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTOM PETERSEN ARCHITECT, LLC05/01/2024
DOB NOWMechanical SystemsPermit IssuedTLS CONSTRUCTION GROUP I*04/19/2024
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC07/17/2023
DOB NOWGeneral ConstructionSigned-offTLS CONSTRUCTION GROUP I*06/21/2023
DOB NOWConstruction FenceSigned-offTLS CONSTRUCTION GROUP I*06/13/2023
1 project · most recent 04/05/2024
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
04/05/2024Permit IssuedTLS CONSTRUCTION GROUP I*Heating Systems
Heating
Williamson GWA-133 133,000 BTU · Boiler ×2
1 project · most recent 04/05/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/05/2024Signed-offCATMAN PLUMBING INCGas, Storm, Water/Sanitary
2 projects · most recent 05/02/2024
General Wiring
FiledStatusContractorScope
05/02/2024CompleteR & T ELECTRICAL CORPGeneral Wiring
04/25/2024CompleteVENTURE HOME SOLAR LLC—
1 project · most recent 04/05/2024
Wood
FiledStatusContractorScope
04/05/2024Permit IssuedTLS CONSTRUCTION GROUP I*Wood
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/03/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/10/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/10/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/10/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 60
DateRequirementInspectorRole
04/25/2024Energy Code Compliance InspectionsTOM PETERSENprogress
04/25/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/25/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/25/2024FinalTOM PETERSENprogress
04/25/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
04/16/2024Chimneys and ventsMEHDI GHAZIspecial
04/16/2024Heating SystemsMEHDI GHAZIspecial
04/16/2024Fire-Resistance Rated ConstructionMEHDI GHAZIprogress
04/16/2024FinalMEHDI GHAZIprogress
04/16/2024Energy Code Compliance InspectionsMEHDI GHAZIprogress
04/16/2024Permanent certificateMEHDI GHAZIenergy_progress
04/16/2024Protection of exposed foundation insulationMEHDI GHAZIenergy_progress
04/16/2024HVAC-R and service water piping design and insulationMEHDI GHAZIenergy_progress
04/16/2024Insulation placement and R valuesMEHDI GHAZIenergy_progress
04/16/2024Air barrier - visual inspectionMEHDI GHAZIenergy_progress
04/16/2024Maintenance informationMEHDI GHAZIenergy_progress
04/16/2024HVAC-R and service water heating system controlsMEHDI GHAZIenergy_progress
04/16/2024Fenestration and door U-factor and product ratingsMEHDI GHAZIenergy_progress
04/16/2024Fenestration areasMEHDI GHAZIenergy_progress
04/16/2024Interior lighting powerMEHDI GHAZIenergy_progress
04/16/2024Fenestration air leakageMEHDI GHAZIenergy_progress
04/16/2024HVAC-R and service water heating equipmentMEHDI GHAZIenergy_progress
04/16/2024Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
04/16/2024Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
04/16/2024Structural Stability – Alterations of existing buildingsMEHDI GHAZIspecial
Latest 25 of 60.
▾Documents — 69 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/24/2026Q00847470-I1Request digital key ↗
08/24/2026Q00847572-S2Request digital key ↗
08/24/2026Q00847572-P2Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00847572-P2Open ↗
08/13/2026Q00847572-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00847572-I1Open ↗
▸Seals & Professional Certifications30
▸DOB NOWSpecial Inspector Seal & Signature12
09/26/2026Q00847572-S1Open ↗
09/26/2026Q00847572-S1Open ↗
09/02/2026Q00847572-S2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/26/2026Q00847572-S1Open ↗
09/02/2026Q00847572-S2Open ↗
09/02/2026Q00847572-S2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/24/2026Q00847470-I1Open ↗
08/22/2026Q01041878-I1Open ↗
08/13/2026Q00847572-P1Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026Q00847572-S1Open ↗
08/13/2026Q00847572-P2Open ↗
08/13/2026Q00847572-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/22/2026Q01041878-I1Open ↗
08/13/2026Q00847572-P1Open ↗
08/13/2026Q00847572-S2Open ↗
Showing 3 of 6 on file for this type
▸Inspections & Test Reports5
▸DOB NOWSOIL REPORT3
08/13/2026Q00847572-P2Open ↗
08/13/2026Q00847572-S1Open ↗
08/13/2026Q00847572-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q00847572-S1Open ↗
08/13/2026Q00847572-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01041878-I1Open ↗
▸Other Documents14
▸DOB NOWSite Survey: Initial3
08/13/2026Q00847572-S1Open ↗
08/13/2026Q00847572-I1Open ↗
08/13/2026Q00847572-P2Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q00847572-P2Open ↗
08/13/2026Q00847572-I1Open ↗
08/13/2026Q00847572-S1Open ↗
▸DOB NOWPlot Diagram3
08/13/2026Q00847572-I1Open ↗
08/13/2026Q00847572-P2Open ↗
08/13/2026Q00847572-S1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026Q00847572-P2Open ↗
08/13/2026Q00847572-I1Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026Q00847572-S1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00847572-S1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00847572-I1Open ↗