← Back
Two family converted from one family
198-19 119 AVENUE
QUEENS · BIN 4435331
💬 Discuss this project
1935Year Built
1.75Stories
B3Building Class
R3AZoning
1,855 sfGross Floor Area
2Units
Two family converted from one family · 3,475 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/09/2014$425K—— → —$229/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC107/01/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VOLTAIC SOLAIRE LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854107/01/2024
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Special Inspection (5)
08/21/2024
Permit issued — Solar
Q01074550-I1-SL
07/01/2024
Filed — Alteration
Installation of PV system on existing roof, no change to egress or use of occupancy
Q01074550-I1
07/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
07/01/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
07/01/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
07/01/2024
Special inspection requirement — Final
TOM PETERSEN
07/01/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedVOLTAIC SOLAIRE LLC08/21/2024
1 project · most recent 06/24/2024
FiledStatusContractorScope
06/24/2024CompleteBERGER QUALITY ELEC'L CON—
1 project · most recent 07/01/2024
FiledStatusContractorScope
07/01/2024Permit IssuedVOLTAIC SOLAIRE LLC20 panels, 8.2 kw, 1,855 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/01/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
07/01/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
07/01/2024Energy Code Compliance InspectionsTOM PETERSENprogress
07/01/2024FinalTOM PETERSENprogress
07/01/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01074550-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/29/2026Q01074550-I1Open ↗
08/29/2026Q01074550-I1Open ↗
08/29/2026Q01074550-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026Q01074550-I1Open ↗
08/29/2026Q01074550-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01074550-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01074550-I1Open ↗