Locations of Work
Architecture
Floor 112p · 1 filing · 12 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
UNION STREET STUDIO, LLC410/28/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ASA CORNER STONE BUILDERSGeneral Contractor107/08/2026
BENT MECHANICAL CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FRANKE GOTTSEGEN COX ARCH996205/20/2022
Building Lifecycle
All (25)Filed (4)Permit Issued (2)Signed Off (1)Violation (4)Inspection (4)Special Inspection (10)
03/24/2023
Violation issued (HPD, closed)
A
12/13/2022
Signed off — Alteration
Upgrade kitchen and bathroom; replacement and relocation of plumbing fixtures, new plumbing fixtures.
B00664703-I1
11/14/2022
Violation issued (HPD, closed)
I
11/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/01/2022
Special inspection requirement — Energy Code Compliance Inspections
Norman Cox
10/28/2022
Filed — Alteration
Upgrade kitchen and bathroom; replacement and relocation of plumbing fixtures, new plumbing fixtures.
B00664703-P1
08/26/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/23/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Norman Cox
05/23/2022
Special inspection requirement — Energy Code Compliance Inspections
Norman Cox
05/23/2022
Special inspection requirement — Fire-Resistance Rated Construction
Norman Cox
05/23/2022
Special inspection requirement — Final
Norman Cox
05/23/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Norman Cox
05/23/2022
Special inspection requirement — Air barrier - visual inspection
Norman Cox
05/23/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Norman Cox
05/23/2022
Special inspection requirement — Fenestration air leakage
Norman Cox
05/23/2022
Special inspection requirement — Lighting in dwelling units
Norman Cox
05/20/2022
Filed — Alteration
B00664236-P1
05/10/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/10/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/27/2022
Permit issued — Plumbing
B00664703-I1-PL
04/21/2022
Permit issued — General Construction
B00664236-I1-GC
03/01/2022
Violation issued (HPD, closed)
A
01/27/2022
Filed — Alteration
Upgrade kitchen and bathroom; replacement and relocation of plumbing fixtures, new plumbing fixtures.
B00664703-I1
01/27/2022
Filed — Alteration
B00664236-I1
04/12/2021
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBENT MECHANICAL CORP04/27/2022
DOB NOWGeneral ConstructionPermit IssuedASA CORNER STONE BUILDERS04/21/2022
1 project · most recent 04/26/2022
General Wiring
FiledStatusContractorScope
04/26/2022CompleteCRESCO ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/26/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/10/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/10/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
11/01/2022Energy Code Compliance InspectionsNorman Coxprogress
05/23/2022Structural Stability – Alterations of existing buildingsNorman Coxspecial
05/23/2022Energy Code Compliance InspectionsNorman Coxprogress
05/23/2022Fire-Resistance Rated ConstructionNorman Coxprogress
05/23/2022FinalNorman Coxprogress
05/23/2022Fire-Resistant Penetrations and JointsNorman Coxspecial
05/23/2022Air barrier - visual inspectionNorman Coxenergy_progress
05/23/2022Fenestration and door U-factor and product ratingsNorman Coxenergy_progress
05/23/2022Fenestration air leakageNorman Coxenergy_progress
05/23/2022Lighting in dwelling unitsNorman Coxenergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/31/2026B00664703-P1Request digital key ↗
08/31/2026B00664703-I1Request digital key ↗
08/29/2026B00664236-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature5
08/25/2026B00664236-I1Open ↗
08/25/2026B00664236-I1Open ↗
08/25/2026B00664236-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/31/2026B00664703-P1Open ↗
08/31/2026B00664703-I1Open ↗
08/29/2026B00664236-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026B00664236-I1Open ↗
08/25/2026B00664236-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/31/2026B00664703-P1Open ↗
08/31/2026B00664703-I1Open ↗
08/29/2026B00664236-P1Open ↗
Showing 3 of 4 on file for this type