ECB05/15/2026AT 4:30AM I OBSERVED 3 STORY EDUCATION BUILDING WITH SIDEWALK SHED INSTALLED AT EXP#1 THAT WAS NOT ILLUMINATED AS STIPULATED AS PER BC3307.6.4.8 THIS CREATE HAZARDOUS CONDITION FOR PEDESTRIANS LEAD TO SLIP, TRI$2K due
ECB04/14/2026AT TIME OF INSPECTION (5:00 AM) I OBSERVED A SIDEWALK SHED ERECTED AT EXPOSURE# 1 WITHOUT THE REQUIRED LIGHTS ON AT THE UNDERSIDE OF THE SHED AS CODE (3307.6.4.8) REQUIRES ALL SIDEWALK SHEDS MUST BE PROPERLY IL$5K due
ECB04/07/2026AT TIME OF INSPECTION OF 7 STORY STALLED SITE OBSERVED SIDEWALK SHED IN PLACE WITH LIGHTING NOT IN OPERATING CONDITIONS CAUSING HAZARDOUS CONDITIONS.MAINTAIN LIGHTING$5K due
ECB03/30/2026AT TIME OF INSPECTION OF ABANDONED NEW BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH ELECTRICAL ROMEX WIRE NOT IN AN ENCLOSED METAL RACEWAY CONDUIT AS CODE REQUIRED CAUSING HAZARDOUS CONDITIONS.PROVIDE REQUIRED$10K due
ECB03/25/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED BUILDING HAS BEEN OBSERVED BEING OPEN AND UNGUARDED TO THE PUBLIC. INDICATIONS CONSISTENT WITH SQUATTER HABITATION (E.G., BEDDING MATERIALS, PERSONAL$3K due
ECB02/19/2026ATOI OBSERVED THE SIDEWALK SHED NOT PROPERLY MAINTAINED. AT EXPOSURE 1, RIGHT SIDE PANEL IS DETERIORATED WITH A VISIBLE HOLE AND ROT AT BASE; HEAVY GRAFFITI PRESENT. MESH GATE IS MISALIGNED; LOOSE WIRES OBSERVE$2K due
ECB10/23/2025AT TIME OF INSPECTION OF 7 STORY NEW BUILDING OBSERVED SIDEWALK SHED IN PLACE NOT MAINTAINED 1. PARAPET PANELS MISSING 2. EXTENSION AT EXPOSURE #4 MISSING 3. NOT FULL WIDTH OF SIDEWALK 4. NOT TIGHT TO FACADE AL$5K due
ECB10/17/2025FOLLOWING UP ON A COMPLAINT OF A CONSTRUCTION EQUIPMENT CREATING AN UNSAFE CONDITION. I OBSERVED AN ABANDONED SITE WITH A HOMELESS ENCAMPMENT AT EXPOSURE ONE, SIDEWALK SHED & FENCE-BC 3303.13. A SPECIFIC SAFETY$10K due
ECB09/23/2025JOBSITE FENCE NOT CONSTRUCTED/MAINTAINED PURSUANT TO SUBSECTION. OBSERVED PANELS NOT PROPERLY SECURED AND SECTION OF FENCE KNOCKED DOWN. REMEDY: COMPLY WITH CODE.$2K due
ECB09/09/2025AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED IN PLACE WITH ACTIVE PERMITS, BUT INADEQUATE ILLUMINATION AS REQUIRED BY BC 3307.6.4.8. THIS CONDITION POSES A RISK OF INJURY TO THE PUBLIC AND INCREASES THE POTENT$5K due
ECB06/23/2025AT TIME OF INSPECTION OF STALLED/ON HOLD NEW BUILDING OBSERVED SIDEWALK SHED IN PLACE NOT MAINTAINED PER CODE 1. MISSING REQUIRED EXTENSION 2. MIRRORS AT BLIND SPOTS 3. NOT TIGHT TO FACADE 4. SHED COVERED IN DE$5K due
ECB06/20/2025AT TIME OF INSPECTION OF 7 STORY NEW STALLED BUILDING SITE WITH SIDEWALK SHED IN PLACE NOT MAINTAINED PER CODE 1. LIGHTING NOT PROVIDED 2. EXTENSION 3. WOULDN'T ENTER IN FEAR TO VERIFY MIRRORS, SIGNS, ETC. ALL$5K due
DOB12/01/2024FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB08/02/2024FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2024FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/22/2024FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/01/2023FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
ECB11/06/2023MISSING VISIBILITY MIRRORS. AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ERECTED WITH NO VISIBILITY MIRRORS PROVIDED ON THE CORNERS OF SIDEWALK SHED PATHWAY CREATING BLIND SPOTS . FAIL TO INSTALL/PROVIDE MIRR$12K due
DOB11/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
ECB09/29/2023AT TIME OF INSPECTION OF 7 STORY NEW BUILDING OBSERVED SIDEWALK SHED IN PLACE WITHOUT MIRRORS AT BLIND SPOTS CAUSING A HAZARDOUS CONDITION TO PUBLIC.PROVIDE MIRRORS AT BLIND SPOTS$5K due
ECB09/07/2023FAILURE TO PROVIDE AND MAINTAIN ADEQUATE HOUSEKEEPING AT STREET STORAGE AREA. RESPONDED VIOLATED CODES 3303.4.2, 3303.4.4, PILES OF COMBUSTIBLE LOOSE DEBRIS WERE FOUND ON SUCH AREA, CREATING HAZARDOUS OF START$3K due
ECB09/07/2023FAILURE TO MAINTAIN STORAGE AREA ON STREET AS PER CODE REQUIREMENTS. IN CONTRARY WITH 3303.4.3 RESPONDED FAILED TO CONTROL AND PROTECT TRAFFIC, NO BARRIERS, SIGNALS, SIGNS, OR OTHER DEVICES WERE PROVIDED CREATI$3K due
ECB08/30/2023AT TIME OF INSPECTION OF NEW 7 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE WITHOUT MIRRORS AT BLIND CORNERS CAUSING A HAZARD TO THE PUBLIC AND INADEQUATE STORAGE IN STREET.PROVIDE MIRRORS AT BLIND CORNERS AN$5K due
DOB08/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
ECB03/21/2023AT TIME OF INSPECTION OF AN ACTIVE 7 STORY BUILDING OBSERVED INADEQUATE GUARDRAIL SYSTEMS AT ELEVATOR SHAFT AND LEADING EDGE OF EXPOSURE 1 ON FLOORS 5 AND 6. IN ADDITION NOT GUARDRAIL SYSTEM PROVIDED ON 7TH FLO$12K due
ECB03/21/2023AT TIME OF RE-INSPECTION OF CLASS 1 VIOLATION #39512131M ISSUED ON 01-25-23, I OBSERVED THAT THE RESPONDENT PROVIDED HANDRAILS BUT FAILED TO MAINTAIN THE SAFETY NETTING FROM CELLAR TO 7TH FL. STEEL CABLES ARE E$6K due
ECB03/21/2023AT TIME OF INSPECTION OF AN ACTIVE 7 STORY SITE I OBSERVED MATERIALS STORED ON LEADING EDGE AT EXPOSURE #1 ON FLOORS 5 AND 6. MATERIALS NEED TO BE STORED 10FT AWAY FROM THE LEADING EDGE AT ALL TIMES TO PREVENT$6K due
ECB01/25/2023AT TIME OF INSPECTION OF AN ACTIVE JOBSITE, UPON REQUEST OF TOOLBOX TALKS LOGS, PRE-SHIFT LOGS AND SWS 6 MONTH PERIODIC INSPECTION REPORT, NONE WAS PROVIDED.$625 due
ECB02/19/2026ATOI OBSERVED THE SIDEWALK SHED NOT PROPERLY MAINTAINED. AT EXPOSURE 1, RIGHT SIDE PANEL IS DETERIORATED WITH A VISIBLE HOLE AND ROT AT BASE; HEAVY GRAFFITI PRESENT. MESH GATE IS MISALIGNED; LOOSE WIRES OBSERVEHearing held — result not yet published
ECB02/19/2026ATOI OBSERVED THE SIDEWALK SHED NOT PROPERLY MAINTAINED. AT EXPOSURE 1, RIGHT SIDE PANEL IS DETERIORATED WITH A VISIBLE HOLE AND ROT AT BASE; HEAVY GRAFFITI PRESENT. MESH GATE IS MISALIGNED; LOOSE WIRES OBSERVENothing owed — awaiting certificate of correction
ECB03/21/2023AT TIME OF INSPECTION OF AN ACTIVE 7 STORY BUILDING OBSERVED INADEQUATE HOUSEKEEPING THROUGHOUT THE SITE. LOOSE CABLES, DEBRIS AND HOLES OBSERVED CREATING A FALLING AND TRIPPING HAZARD. HOUSEKEEPING NEEDS TO BENothing owed — awaiting certificate of correction
Mission house (non-residential) · Owner of record: MET COMM METH CHURCH · 5,395 sf lot · 19.97 FAR built · Flood zone X