← Back
Four families
1983 WEST 10 STREET
BROOKLYN · Gravesend (West) · BIN 3189959
💬 Discuss this project
1926Year Built
2Stories
C3Building Class
R4-1Zoning
3,120 sfGross Floor Area
4Units
Rent Stabilized8 Open Violations 6 unresolved · 2 paperwork only ▸FDNY Report ↗
Four families · 2,500 sf lot · 1.25 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbing
Cellar2p · 2 filings · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.201/27/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SO PLUMBING & HEATING INCPlumbing307/08/2026
HIGH QUALITY CONSTRUCTIONGeneral Contractor203/21/2026
KJK ELECTRIC INCElectrical103/21/2026
ZHENG LIElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781201/27/2021
Building Lifecycle
All (39)Filed (2)Permit Issued (2)Signed Off (2)Violation (33)
05/06/2026
Violation issued (HPD, open)
A
02/16/2026
Violation issued (HPD, closed)
C
02/16/2026
Violation issued (HPD, closed)
C
02/16/2026
Violation issued (HPD, closed)
A
02/16/2026
Violation issued (HPD, open)
C
02/16/2026
Violation issued (HPD, open)
C
02/16/2026
Violation issued (HPD, open)
B
02/16/2026
Violation issued (HPD, open)
B
06/11/2025
Violation issued (HPD, open)
A
11/27/2024
Violation issued (HPD, closed)
I
04/12/2024
Violation issued (HPD, closed)
A
11/21/2023
Violation issued (HPD, closed)
I
03/27/2023
Violation issued (HPD, closed)
A
10/05/2022
Violation issued (ECB, open)
Construction
10/05/2022
Violation issued (ECB, open)
Quality of Life
03/02/2022
Violation issued (HPD, closed)
A
04/07/2021
Violation issued (ECB, closed)
Construction
03/09/2021
Violation issued (ECB, closed)
Construction
03/04/2021
Signed off — Alteration
B00456952-I1
03/04/2021
Signed off — Alteration
B00456957-I1
02/19/2021
Permit issued — Plumbing
B00456957-I1-PL
02/16/2021
Permit issued — General Construction
B00456952-I1-GC
01/27/2021
Filed — Alteration
B00456957-I1
01/25/2021
Filed — Alteration
B00456952-I1
01/14/2021
Violation issued (ECB, closed)
Construction
01/14/2021
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
01/12/2021
Violation issued (ECB, closed)
Unknown
01/12/2021
Violation issued (ECB, closed)
Construction
11/19/2020
Violation issued (HPD, closed)
B
11/19/2020
Violation issued (HPD, closed)
B
11/19/2020
Violation issued (HPD, closed)
C
11/19/2020
Violation issued (HPD, closed)
B
11/19/2020
Violation issued (HPD, closed)
B
11/19/2020
Violation issued (HPD, closed)
B
11/19/2020
Violation issued (HPD, closed)
B
11/19/2020
Violation issued (HPD, closed)
C
11/19/2020
Violation issued (HPD, closed)
C
11/19/2020
Violation issued (HPD, closed)
B
11/19/2020
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offNICHOLAS SUIDA02/19/2021
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION02/16/2021
1 project · most recent 02/05/2021
General Wiring
FiledStatusContractorScope
02/05/2021CompleteKJK ELECTRIC INCGeneral Wiring
Nothing on file for this building.
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing1
09/01/2026B00456957-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
09/01/2026B00456952-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
09/01/2026B00456952-I1Open ↗
09/01/2026B00456957-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/01/2026B00456952-I1Open ↗
09/01/2026B00456957-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00456952-I1Open ↗